Redox switching of Prussian blue thin films investigated by ac-electrogravimetry
In this paper, the redox switching behaviour of Prussian blue (PB) in KCl environment at pH 2.5 and 5.4 was investigated by using ac-electrogravimetry in a potential range around the conversion of PB to ES (Everitt Salt). This technique allows the electrochemical impedance and a mass–potential trans...
Gespeichert in:
Veröffentlicht in: | Electrochimica acta 2012-12, Vol.84, p.35-48 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 48 |
---|---|
container_issue | |
container_start_page | 35 |
container_title | Electrochimica acta |
container_volume | 84 |
creator | Kim, L. To Thi Gabrielli, C. Perrot, H. Garcia-Jareno, J. Vicente, F. |
description | In this paper, the redox switching behaviour of Prussian blue (PB) in KCl environment at pH 2.5 and 5.4 was investigated by using ac-electrogravimetry in a potential range around the conversion of PB to ES (Everitt Salt). This technique allows the electrochemical impedance and a mass–potential transfer function to be simultaneously measured. From the impedance the charge–potential transfer function is calculated. A model of the PB film, is presented, it takes into account the porous structure of the material, the insertion of two cations on the pore wall, and the electronic charge transfer from the electrode. A fitting procedure was employed to obtain the kinetic parameters.
Attractive information extracted from the impedance concerns the porosity of the PB film which is related to the zeolitic nature of the film. The resistivity of the pore depends obviously on the electrolyte conductance and changes with respect to the potential with a minimum, in the vicinity of the PB↔ES conversion potential.
Ac-electrogravimetry and the charge–potential transfer function gave essentially information on the kinetics of the ionic transfer. Thanks to the model of electroactive porous films and the digital fitting procedure, for the first time, the two cations K+ and H3O+ are identified with well separated kinetics for each cation. Several attractive informations were reached. First, it confirms that ionic transfer at the film/electrolyte interface limits the kinetics of the film reduction or oxidation as electronic transfer at the electrode/film interface is faster. Moreover, the rates of the electronic and ionic transfer kinetics vary with the potential. They are faster around the potential where the PB↔ES conversion occurs. It was confirmed that charge compensation occurs only by K+ and H3O+ movements whatever the pH of the solution. However, H3O+ transfer kinetics is faster than K+ transfer, whatever the KCl concentration, and the role of H3O+ is more important for large KCl concentrations where the process is more limited by the kinetics of the hydronium ions. In addition, in these situations, even if ionic transfer is also accelerated the global charge transfer is nevertheless more controlled by electronic transfer. |
doi_str_mv | 10.1016/j.electacta.2012.06.049 |
format | Article |
fullrecord | <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00790548v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0013468612010249</els_id><sourcerecordid>1365115906</sourcerecordid><originalsourceid>FETCH-LOGICAL-c563t-a77b46140079c14be18a816c9957009c98edab92077b5778083ea120295cf8623</originalsourceid><addsrcrecordid>eNqFkdtq3DAQhkVoIdu0zxBdJhd2Z3zQ4XIJOcFCQmmvhSyPN1q8diJ5N9m3j5wtuQ0MDAzf_HP4GTtHyBFQ_N7k1JObbIq8ACxyEDlU-oQtUMkyK1Wtv7EFAJZZJZQ4ZT9i3ACAFBIW7PEPteMbj69-ck9-WPOx449hF6O3A2_6HfEplXnn-23kfthTnPzaTtTy5sCtyz5mh3Ed7N5vaQqHn-x7Z_tIv_7nM_bv5vrv1V22eri9v1quMleLcsqslE0lsEp7aIdVQ6isQuG0riWAdlpRaxtdQOJqKRWokiwWUOjadUoU5Rm7POo-2d48B7-14WBG683dcmXm2qwMdaX2mNiLI_scxpddOsFsfXTU93agcRcNColVQoX4Gi1FjVhrmFF5RF0YYwzUfa6BYGZrzMZ8WmNmawwIk6xJnctjJ6UH7T0FE52nwVHrQ-JNO_ovNd4Bv1yaAg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1365115906</pqid></control><display><type>article</type><title>Redox switching of Prussian blue thin films investigated by ac-electrogravimetry</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Kim, L. To Thi ; Gabrielli, C. ; Perrot, H. ; Garcia-Jareno, J. ; Vicente, F.</creator><creatorcontrib>Kim, L. To Thi ; Gabrielli, C. ; Perrot, H. ; Garcia-Jareno, J. ; Vicente, F.</creatorcontrib><description>In this paper, the redox switching behaviour of Prussian blue (PB) in KCl environment at pH 2.5 and 5.4 was investigated by using ac-electrogravimetry in a potential range around the conversion of PB to ES (Everitt Salt). This technique allows the electrochemical impedance and a mass–potential transfer function to be simultaneously measured. From the impedance the charge–potential transfer function is calculated. A model of the PB film, is presented, it takes into account the porous structure of the material, the insertion of two cations on the pore wall, and the electronic charge transfer from the electrode. A fitting procedure was employed to obtain the kinetic parameters.
Attractive information extracted from the impedance concerns the porosity of the PB film which is related to the zeolitic nature of the film. The resistivity of the pore depends obviously on the electrolyte conductance and changes with respect to the potential with a minimum, in the vicinity of the PB↔ES conversion potential.
Ac-electrogravimetry and the charge–potential transfer function gave essentially information on the kinetics of the ionic transfer. Thanks to the model of electroactive porous films and the digital fitting procedure, for the first time, the two cations K+ and H3O+ are identified with well separated kinetics for each cation. Several attractive informations were reached. First, it confirms that ionic transfer at the film/electrolyte interface limits the kinetics of the film reduction or oxidation as electronic transfer at the electrode/film interface is faster. Moreover, the rates of the electronic and ionic transfer kinetics vary with the potential. They are faster around the potential where the PB↔ES conversion occurs. It was confirmed that charge compensation occurs only by K+ and H3O+ movements whatever the pH of the solution. However, H3O+ transfer kinetics is faster than K+ transfer, whatever the KCl concentration, and the role of H3O+ is more important for large KCl concentrations where the process is more limited by the kinetics of the hydronium ions. In addition, in these situations, even if ionic transfer is also accelerated the global charge transfer is nevertheless more controlled by electronic transfer.</description><identifier>ISSN: 0013-4686</identifier><identifier>EISSN: 1873-3859</identifier><identifier>DOI: 10.1016/j.electacta.2012.06.049</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>ac-electrogravimetry ; Chemical Sciences ; Conversion ; Electrodes ; Electronic transfer ; Electronics ; Ionic transfer ; Mathematical models ; Other ; Porosity ; Prussian blue ; Switching ; Thin films ; Transfer functions ; Walls</subject><ispartof>Electrochimica acta, 2012-12, Vol.84, p.35-48</ispartof><rights>2012 Elsevier Ltd</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c563t-a77b46140079c14be18a816c9957009c98edab92077b5778083ea120295cf8623</citedby><cites>FETCH-LOGICAL-c563t-a77b46140079c14be18a816c9957009c98edab92077b5778083ea120295cf8623</cites><orcidid>0000-0002-3930-2968</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.electacta.2012.06.049$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,780,784,885,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://hal.sorbonne-universite.fr/hal-00790548$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, L. To Thi</creatorcontrib><creatorcontrib>Gabrielli, C.</creatorcontrib><creatorcontrib>Perrot, H.</creatorcontrib><creatorcontrib>Garcia-Jareno, J.</creatorcontrib><creatorcontrib>Vicente, F.</creatorcontrib><title>Redox switching of Prussian blue thin films investigated by ac-electrogravimetry</title><title>Electrochimica acta</title><description>In this paper, the redox switching behaviour of Prussian blue (PB) in KCl environment at pH 2.5 and 5.4 was investigated by using ac-electrogravimetry in a potential range around the conversion of PB to ES (Everitt Salt). This technique allows the electrochemical impedance and a mass–potential transfer function to be simultaneously measured. From the impedance the charge–potential transfer function is calculated. A model of the PB film, is presented, it takes into account the porous structure of the material, the insertion of two cations on the pore wall, and the electronic charge transfer from the electrode. A fitting procedure was employed to obtain the kinetic parameters.
Attractive information extracted from the impedance concerns the porosity of the PB film which is related to the zeolitic nature of the film. The resistivity of the pore depends obviously on the electrolyte conductance and changes with respect to the potential with a minimum, in the vicinity of the PB↔ES conversion potential.
Ac-electrogravimetry and the charge–potential transfer function gave essentially information on the kinetics of the ionic transfer. Thanks to the model of electroactive porous films and the digital fitting procedure, for the first time, the two cations K+ and H3O+ are identified with well separated kinetics for each cation. Several attractive informations were reached. First, it confirms that ionic transfer at the film/electrolyte interface limits the kinetics of the film reduction or oxidation as electronic transfer at the electrode/film interface is faster. Moreover, the rates of the electronic and ionic transfer kinetics vary with the potential. They are faster around the potential where the PB↔ES conversion occurs. It was confirmed that charge compensation occurs only by K+ and H3O+ movements whatever the pH of the solution. However, H3O+ transfer kinetics is faster than K+ transfer, whatever the KCl concentration, and the role of H3O+ is more important for large KCl concentrations where the process is more limited by the kinetics of the hydronium ions. In addition, in these situations, even if ionic transfer is also accelerated the global charge transfer is nevertheless more controlled by electronic transfer.</description><subject>ac-electrogravimetry</subject><subject>Chemical Sciences</subject><subject>Conversion</subject><subject>Electrodes</subject><subject>Electronic transfer</subject><subject>Electronics</subject><subject>Ionic transfer</subject><subject>Mathematical models</subject><subject>Other</subject><subject>Porosity</subject><subject>Prussian blue</subject><subject>Switching</subject><subject>Thin films</subject><subject>Transfer functions</subject><subject>Walls</subject><issn>0013-4686</issn><issn>1873-3859</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqFkdtq3DAQhkVoIdu0zxBdJhd2Z3zQ4XIJOcFCQmmvhSyPN1q8diJ5N9m3j5wtuQ0MDAzf_HP4GTtHyBFQ_N7k1JObbIq8ACxyEDlU-oQtUMkyK1Wtv7EFAJZZJZQ4ZT9i3ACAFBIW7PEPteMbj69-ck9-WPOx449hF6O3A2_6HfEplXnn-23kfthTnPzaTtTy5sCtyz5mh3Ed7N5vaQqHn-x7Z_tIv_7nM_bv5vrv1V22eri9v1quMleLcsqslE0lsEp7aIdVQ6isQuG0riWAdlpRaxtdQOJqKRWokiwWUOjadUoU5Rm7POo-2d48B7-14WBG683dcmXm2qwMdaX2mNiLI_scxpddOsFsfXTU93agcRcNColVQoX4Gi1FjVhrmFF5RF0YYwzUfa6BYGZrzMZ8WmNmawwIk6xJnctjJ6UH7T0FE52nwVHrQ-JNO_ovNd4Bv1yaAg</recordid><startdate>20121201</startdate><enddate>20121201</enddate><creator>Kim, L. To Thi</creator><creator>Gabrielli, C.</creator><creator>Perrot, H.</creator><creator>Garcia-Jareno, J.</creator><creator>Vicente, F.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7SP</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-3930-2968</orcidid></search><sort><creationdate>20121201</creationdate><title>Redox switching of Prussian blue thin films investigated by ac-electrogravimetry</title><author>Kim, L. To Thi ; Gabrielli, C. ; Perrot, H. ; Garcia-Jareno, J. ; Vicente, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c563t-a77b46140079c14be18a816c9957009c98edab92077b5778083ea120295cf8623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>ac-electrogravimetry</topic><topic>Chemical Sciences</topic><topic>Conversion</topic><topic>Electrodes</topic><topic>Electronic transfer</topic><topic>Electronics</topic><topic>Ionic transfer</topic><topic>Mathematical models</topic><topic>Other</topic><topic>Porosity</topic><topic>Prussian blue</topic><topic>Switching</topic><topic>Thin films</topic><topic>Transfer functions</topic><topic>Walls</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, L. To Thi</creatorcontrib><creatorcontrib>Gabrielli, C.</creatorcontrib><creatorcontrib>Perrot, H.</creatorcontrib><creatorcontrib>Garcia-Jareno, J.</creatorcontrib><creatorcontrib>Vicente, F.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Electronics & Communications Abstracts</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Electrochimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, L. To Thi</au><au>Gabrielli, C.</au><au>Perrot, H.</au><au>Garcia-Jareno, J.</au><au>Vicente, F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Redox switching of Prussian blue thin films investigated by ac-electrogravimetry</atitle><jtitle>Electrochimica acta</jtitle><date>2012-12-01</date><risdate>2012</risdate><volume>84</volume><spage>35</spage><epage>48</epage><pages>35-48</pages><issn>0013-4686</issn><eissn>1873-3859</eissn><abstract>In this paper, the redox switching behaviour of Prussian blue (PB) in KCl environment at pH 2.5 and 5.4 was investigated by using ac-electrogravimetry in a potential range around the conversion of PB to ES (Everitt Salt). This technique allows the electrochemical impedance and a mass–potential transfer function to be simultaneously measured. From the impedance the charge–potential transfer function is calculated. A model of the PB film, is presented, it takes into account the porous structure of the material, the insertion of two cations on the pore wall, and the electronic charge transfer from the electrode. A fitting procedure was employed to obtain the kinetic parameters.
Attractive information extracted from the impedance concerns the porosity of the PB film which is related to the zeolitic nature of the film. The resistivity of the pore depends obviously on the electrolyte conductance and changes with respect to the potential with a minimum, in the vicinity of the PB↔ES conversion potential.
Ac-electrogravimetry and the charge–potential transfer function gave essentially information on the kinetics of the ionic transfer. Thanks to the model of electroactive porous films and the digital fitting procedure, for the first time, the two cations K+ and H3O+ are identified with well separated kinetics for each cation. Several attractive informations were reached. First, it confirms that ionic transfer at the film/electrolyte interface limits the kinetics of the film reduction or oxidation as electronic transfer at the electrode/film interface is faster. Moreover, the rates of the electronic and ionic transfer kinetics vary with the potential. They are faster around the potential where the PB↔ES conversion occurs. It was confirmed that charge compensation occurs only by K+ and H3O+ movements whatever the pH of the solution. However, H3O+ transfer kinetics is faster than K+ transfer, whatever the KCl concentration, and the role of H3O+ is more important for large KCl concentrations where the process is more limited by the kinetics of the hydronium ions. In addition, in these situations, even if ionic transfer is also accelerated the global charge transfer is nevertheless more controlled by electronic transfer.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.electacta.2012.06.049</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0002-3930-2968</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0013-4686 |
ispartof | Electrochimica acta, 2012-12, Vol.84, p.35-48 |
issn | 0013-4686 1873-3859 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_00790548v1 |
source | Elsevier ScienceDirect Journals Complete |
subjects | ac-electrogravimetry Chemical Sciences Conversion Electrodes Electronic transfer Electronics Ionic transfer Mathematical models Other Porosity Prussian blue Switching Thin films Transfer functions Walls |
title | Redox switching of Prussian blue thin films investigated by ac-electrogravimetry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A16%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Redox%20switching%20of%20Prussian%20blue%20thin%20films%20investigated%20by%20ac-electrogravimetry&rft.jtitle=Electrochimica%20acta&rft.au=Kim,%20L.%20To%20Thi&rft.date=2012-12-01&rft.volume=84&rft.spage=35&rft.epage=48&rft.pages=35-48&rft.issn=0013-4686&rft.eissn=1873-3859&rft_id=info:doi/10.1016/j.electacta.2012.06.049&rft_dat=%3Cproquest_hal_p%3E1365115906%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1365115906&rft_id=info:pmid/&rft_els_id=S0013468612010249&rfr_iscdi=true |