PIXSCAN is the first micro-CT prototype based on XPAD hybrid pixel detectors whose properties (high signal to noise ratio and detection efficiency) theoretically allow imaging at low irradiation dose. We have tested the impact of repeated imaging sessions with PIXSCAN on living mice. Mice were subje...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2010, Vol.57, p.242-245
Hauptverfasser: Debarbieux, F., Bonissent, A., Breugnon, P., Cassol-Breuner, F., Delpierre, P., Hemmer, C., Clemens, J.C., Dinkespiler, B., Luchino, J., Mann, F., Meesen, C., Vigeolas, E., Rougon, G., Morel, C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 245
container_issue
container_start_page 242
container_title IEEE transactions on nuclear science
container_volume 57
creator Debarbieux, F.
Bonissent, A.
Breugnon, P.
Cassol-Breuner, F.
Delpierre, P.
Hemmer, C.
Clemens, J.C.
Dinkespiler, B.
Luchino, J.
Mann, F.
Meesen, C.
Vigeolas, E.
Rougon, G.
Morel, C.
description PIXSCAN is the first micro-CT prototype based on XPAD hybrid pixel detectors whose properties (high signal to noise ratio and detection efficiency) theoretically allow imaging at low irradiation dose. We have tested the impact of repeated imaging sessions with PIXSCAN on living mice. Mice were subjected on average to 10 imaging sessions over two weeks without any detectable sign of X-ray injuries as assessed by spontaneous activity in the cage, examination of hair and skin, or comparison of lung absorbing properties for X-rays. PIXSCAN was therefore used to detect and non-invasively monitor the progression of lung metastasis in a murine model of cancer. Aim was two-fold: i) to provide imaging assistance to decide timing of animal sacrifice for subsequent histological characterization; ii) to optimize imaging protocol to allow direct evaluation of new therapeutic agents to stop cancer progression. Comparing in vivo tomographic reconstruction of freely breathing mice with post mortem examination of their lungs, we have shown that identification and localization of millimetric tumors was compatible with X-ray imaging protocol delivering only 10 mGy per exam.
doi_str_mv 10.1109/TNS.2009.2037319
format Article
fullrecord <record><control><sourceid>hal</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00507491v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_hal_00507491v1</sourcerecordid><originalsourceid>FETCH-hal_primary_oai_HAL_hal_00507491v13</originalsourceid><addsrcrecordid>eNqVTsFKw0AUXETBWL17fFfB1LcmS7LHEJUKUkqbQ29hm7y2K5ts2E2r9evdgj_gZYYZZoZh7J7jlHOUT9V8NX1GlAGSLOHygkVciDzmIssvWYTI81imUl6zG-8_g0wFioj9LGkgNVILulM73e_AbsEcAjeqb8hBS0cyduioH-Hgz4HF-3pVFvNHUGDsF7TWE3S6cbaswIdWH1ob5cOk7WG9KF5gf9o43cKgv8mEwZGa0Tp_y662yni6--MJe3h7rcpZvFemHlz44061VbqeFR_12UMUmKWSH3nyn-wv549XTQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Repeated imaging of lung cancer development using PIXSCAN, a low dose microCT scanner based on XPAD hybrid pixel detectors</title><source>IEEE Electronic Library (IEL)</source><creator>Debarbieux, F. ; Bonissent, A. ; Breugnon, P. ; Cassol-Breuner, F. ; Delpierre, P. ; Hemmer, C. ; Clemens, J.C. ; Dinkespiler, B. ; Luchino, J. ; Mann, F. ; Meesen, C. ; Vigeolas, E. ; Rougon, G. ; Morel, C.</creator><creatorcontrib>Debarbieux, F. ; Bonissent, A. ; Breugnon, P. ; Cassol-Breuner, F. ; Delpierre, P. ; Hemmer, C. ; Clemens, J.C. ; Dinkespiler, B. ; Luchino, J. ; Mann, F. ; Meesen, C. ; Vigeolas, E. ; Rougon, G. ; Morel, C.</creatorcontrib><description>PIXSCAN is the first micro-CT prototype based on XPAD hybrid pixel detectors whose properties (high signal to noise ratio and detection efficiency) theoretically allow imaging at low irradiation dose. We have tested the impact of repeated imaging sessions with PIXSCAN on living mice. Mice were subjected on average to 10 imaging sessions over two weeks without any detectable sign of X-ray injuries as assessed by spontaneous activity in the cage, examination of hair and skin, or comparison of lung absorbing properties for X-rays. PIXSCAN was therefore used to detect and non-invasively monitor the progression of lung metastasis in a murine model of cancer. Aim was two-fold: i) to provide imaging assistance to decide timing of animal sacrifice for subsequent histological characterization; ii) to optimize imaging protocol to allow direct evaluation of new therapeutic agents to stop cancer progression. Comparing in vivo tomographic reconstruction of freely breathing mice with post mortem examination of their lungs, we have shown that identification and localization of millimetric tumors was compatible with X-ray imaging protocol delivering only 10 mGy per exam.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2009.2037319</identifier><language>eng</language><publisher>Institute of Electrical and Electronics Engineers</publisher><subject>Cellular Biology ; Life Sciences</subject><ispartof>IEEE transactions on nuclear science, 2010, Vol.57, p.242-245</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttps://hal.science/hal-00507491$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Debarbieux, F.</creatorcontrib><creatorcontrib>Bonissent, A.</creatorcontrib><creatorcontrib>Breugnon, P.</creatorcontrib><creatorcontrib>Cassol-Breuner, F.</creatorcontrib><creatorcontrib>Delpierre, P.</creatorcontrib><creatorcontrib>Hemmer, C.</creatorcontrib><creatorcontrib>Clemens, J.C.</creatorcontrib><creatorcontrib>Dinkespiler, B.</creatorcontrib><creatorcontrib>Luchino, J.</creatorcontrib><creatorcontrib>Mann, F.</creatorcontrib><creatorcontrib>Meesen, C.</creatorcontrib><creatorcontrib>Vigeolas, E.</creatorcontrib><creatorcontrib>Rougon, G.</creatorcontrib><creatorcontrib>Morel, C.</creatorcontrib><title>Repeated imaging of lung cancer development using PIXSCAN, a low dose microCT scanner based on XPAD hybrid pixel detectors</title><title>IEEE transactions on nuclear science</title><description>PIXSCAN is the first micro-CT prototype based on XPAD hybrid pixel detectors whose properties (high signal to noise ratio and detection efficiency) theoretically allow imaging at low irradiation dose. We have tested the impact of repeated imaging sessions with PIXSCAN on living mice. Mice were subjected on average to 10 imaging sessions over two weeks without any detectable sign of X-ray injuries as assessed by spontaneous activity in the cage, examination of hair and skin, or comparison of lung absorbing properties for X-rays. PIXSCAN was therefore used to detect and non-invasively monitor the progression of lung metastasis in a murine model of cancer. Aim was two-fold: i) to provide imaging assistance to decide timing of animal sacrifice for subsequent histological characterization; ii) to optimize imaging protocol to allow direct evaluation of new therapeutic agents to stop cancer progression. Comparing in vivo tomographic reconstruction of freely breathing mice with post mortem examination of their lungs, we have shown that identification and localization of millimetric tumors was compatible with X-ray imaging protocol delivering only 10 mGy per exam.</description><subject>Cellular Biology</subject><subject>Life Sciences</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqVTsFKw0AUXETBWL17fFfB1LcmS7LHEJUKUkqbQ29hm7y2K5ts2E2r9evdgj_gZYYZZoZh7J7jlHOUT9V8NX1GlAGSLOHygkVciDzmIssvWYTI81imUl6zG-8_g0wFioj9LGkgNVILulM73e_AbsEcAjeqb8hBS0cyduioH-Hgz4HF-3pVFvNHUGDsF7TWE3S6cbaswIdWH1ob5cOk7WG9KF5gf9o43cKgv8mEwZGa0Tp_y662yni6--MJe3h7rcpZvFemHlz44061VbqeFR_12UMUmKWSH3nyn-wv549XTQ</recordid><startdate>2010</startdate><enddate>2010</enddate><creator>Debarbieux, F.</creator><creator>Bonissent, A.</creator><creator>Breugnon, P.</creator><creator>Cassol-Breuner, F.</creator><creator>Delpierre, P.</creator><creator>Hemmer, C.</creator><creator>Clemens, J.C.</creator><creator>Dinkespiler, B.</creator><creator>Luchino, J.</creator><creator>Mann, F.</creator><creator>Meesen, C.</creator><creator>Vigeolas, E.</creator><creator>Rougon, G.</creator><creator>Morel, C.</creator><general>Institute of Electrical and Electronics Engineers</general><scope>1XC</scope></search><sort><creationdate>2010</creationdate><title>Repeated imaging of lung cancer development using PIXSCAN, a low dose microCT scanner based on XPAD hybrid pixel detectors</title><author>Debarbieux, F. ; Bonissent, A. ; Breugnon, P. ; Cassol-Breuner, F. ; Delpierre, P. ; Hemmer, C. ; Clemens, J.C. ; Dinkespiler, B. ; Luchino, J. ; Mann, F. ; Meesen, C. ; Vigeolas, E. ; Rougon, G. ; Morel, C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-hal_primary_oai_HAL_hal_00507491v13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Cellular Biology</topic><topic>Life Sciences</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Debarbieux, F.</creatorcontrib><creatorcontrib>Bonissent, A.</creatorcontrib><creatorcontrib>Breugnon, P.</creatorcontrib><creatorcontrib>Cassol-Breuner, F.</creatorcontrib><creatorcontrib>Delpierre, P.</creatorcontrib><creatorcontrib>Hemmer, C.</creatorcontrib><creatorcontrib>Clemens, J.C.</creatorcontrib><creatorcontrib>Dinkespiler, B.</creatorcontrib><creatorcontrib>Luchino, J.</creatorcontrib><creatorcontrib>Mann, F.</creatorcontrib><creatorcontrib>Meesen, C.</creatorcontrib><creatorcontrib>Vigeolas, E.</creatorcontrib><creatorcontrib>Rougon, G.</creatorcontrib><creatorcontrib>Morel, C.</creatorcontrib><collection>Hyper Article en Ligne (HAL)</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Debarbieux, F.</au><au>Bonissent, A.</au><au>Breugnon, P.</au><au>Cassol-Breuner, F.</au><au>Delpierre, P.</au><au>Hemmer, C.</au><au>Clemens, J.C.</au><au>Dinkespiler, B.</au><au>Luchino, J.</au><au>Mann, F.</au><au>Meesen, C.</au><au>Vigeolas, E.</au><au>Rougon, G.</au><au>Morel, C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Repeated imaging of lung cancer development using PIXSCAN, a low dose microCT scanner based on XPAD hybrid pixel detectors</atitle><jtitle>IEEE transactions on nuclear science</jtitle><date>2010</date><risdate>2010</risdate><volume>57</volume><spage>242</spage><epage>245</epage><pages>242-245</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><abstract>PIXSCAN is the first micro-CT prototype based on XPAD hybrid pixel detectors whose properties (high signal to noise ratio and detection efficiency) theoretically allow imaging at low irradiation dose. We have tested the impact of repeated imaging sessions with PIXSCAN on living mice. Mice were subjected on average to 10 imaging sessions over two weeks without any detectable sign of X-ray injuries as assessed by spontaneous activity in the cage, examination of hair and skin, or comparison of lung absorbing properties for X-rays. PIXSCAN was therefore used to detect and non-invasively monitor the progression of lung metastasis in a murine model of cancer. Aim was two-fold: i) to provide imaging assistance to decide timing of animal sacrifice for subsequent histological characterization; ii) to optimize imaging protocol to allow direct evaluation of new therapeutic agents to stop cancer progression. Comparing in vivo tomographic reconstruction of freely breathing mice with post mortem examination of their lungs, we have shown that identification and localization of millimetric tumors was compatible with X-ray imaging protocol delivering only 10 mGy per exam.</abstract><pub>Institute of Electrical and Electronics Engineers</pub><doi>10.1109/TNS.2009.2037319</doi></addata></record>
fulltext fulltext
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2010, Vol.57, p.242-245
issn 0018-9499
1558-1578
language eng
recordid cdi_hal_primary_oai_HAL_hal_00507491v1
source IEEE Electronic Library (IEL)
subjects Cellular Biology
Life Sciences
title Repeated imaging of lung cancer development using PIXSCAN, a low dose microCT scanner based on XPAD hybrid pixel detectors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T04%3A04%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Repeated%20imaging%20of%20lung%20cancer%20development%20using%20PIXSCAN,%20a%20low%20dose%20microCT%20scanner%20based%20on%20XPAD%20hybrid%20pixel%20detectors&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Debarbieux,%20F.&rft.date=2010&rft.volume=57&rft.spage=242&rft.epage=245&rft.pages=242-245&rft.issn=0018-9499&rft.eissn=1558-1578&rft_id=info:doi/10.1109/TNS.2009.2037319&rft_dat=%3Chal%3Eoai_HAL_hal_00507491v1%3C/hal%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true