Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry
We characterized two samples consisting of photoresist layers on silicon with square arrays of square holes by spectroscopic ellipsometry (SE) and Mueller matrix polarimetry (MMP). Hole lateral dimensions and depths were determined by fitting either SE data taken in conventional planar geometry or M...
Gespeichert in:
Veröffentlicht in: | European physical journal. Applied physics 2008, Vol.42 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | European physical journal. Applied physics |
container_volume | 42 |
creator | Foldyna, Martin de Martino, Antonello Garcia-Caurel, Enric Ossikovski, Razvigor Licitra, C. Bertin, François Postava, Kamil Drévillon, Bernard |
description | We characterized two samples consisting of photoresist layers on silicon with square arrays of square holes by spectroscopic ellipsometry (SE) and Mueller matrix polarimetry (MMP). Hole lateral dimensions and depths were determined by fitting either SE data taken in conventional planar geometry or MMP data in general conical diffraction configurations. A method for objective determination of the optimal measurement conditions based on sensitivity and parameter correlations is presented.When applied to MMP, this approach showed that for one of the samples the optimal incidence angle was 45◦, much below the widely used 70 degrees value. The robustness of the dimensional characterisation based on MMP is demonstrated by the high stability of the results provided by separated fits of the data taken at different azimuthal angles. |
doi_str_mv | 10.1051/epjap:2008089 |
format | Article |
fullrecord | <record><control><sourceid>hal</sourceid><recordid>TN_cdi_hal_primary_oai_HAL_hal_00458659v1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_HAL_hal_00458659v1</sourcerecordid><originalsourceid>FETCH-hal_primary_oai_HAL_hal_00458659v13</originalsourceid><addsrcrecordid>eNqVjrFOAzEQRC1EJAKhpN-WIrA-8MmhQxEoRejoT855Ezby2dbaIO7vORCip5rRzBtplLrSeKPR6FvKR5cfGkSLdnWi5rqx7RLR4Omfv2_O1HkpR0TUrTVzNayFK_cugOeBYuEUC6Q97DiTcPLcw0Fc5Xgo4KmSDBzJw26EkqmvMg0pBM4lDVRlBBc9vLxPEQkMrgp_Qk7BCf_UCzXbu1Do8lcv1PXz0-t6s3xzocsT5GTskuNu87jtvrPpsbGtWX3ou_-wXwc5VbE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry</title><source>Bacon EDP Sciences France Licence nationale-ISTEX-PS-Journals-PFISTEX</source><source>EDP Sciences</source><creator>Foldyna, Martin ; de Martino, Antonello ; Garcia-Caurel, Enric ; Ossikovski, Razvigor ; Licitra, C. ; Bertin, François ; Postava, Kamil ; Drévillon, Bernard</creator><creatorcontrib>Foldyna, Martin ; de Martino, Antonello ; Garcia-Caurel, Enric ; Ossikovski, Razvigor ; Licitra, C. ; Bertin, François ; Postava, Kamil ; Drévillon, Bernard</creatorcontrib><description>We characterized two samples consisting of photoresist layers on silicon with square arrays of square holes by spectroscopic ellipsometry (SE) and Mueller matrix polarimetry (MMP). Hole lateral dimensions and depths were determined by fitting either SE data taken in conventional planar geometry or MMP data in general conical diffraction configurations. A method for objective determination of the optimal measurement conditions based on sensitivity and parameter correlations is presented.When applied to MMP, this approach showed that for one of the samples the optimal incidence angle was 45◦, much below the widely used 70 degrees value. The robustness of the dimensional characterisation based on MMP is demonstrated by the high stability of the results provided by separated fits of the data taken at different azimuthal angles.</description><identifier>ISSN: 1286-0042</identifier><identifier>EISSN: 1286-0050</identifier><identifier>DOI: 10.1051/epjap:2008089</identifier><language>eng</language><publisher>EDP Sciences</publisher><subject>Optics ; Physics</subject><ispartof>European physical journal. Applied physics, 2008, Vol.42</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-4309-3310 ; 0000-0001-8413-0504 ; 0000-0002-4309-3310 ; 0000-0001-8413-0504</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://hal.science/hal-00458659$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Foldyna, Martin</creatorcontrib><creatorcontrib>de Martino, Antonello</creatorcontrib><creatorcontrib>Garcia-Caurel, Enric</creatorcontrib><creatorcontrib>Ossikovski, Razvigor</creatorcontrib><creatorcontrib>Licitra, C.</creatorcontrib><creatorcontrib>Bertin, François</creatorcontrib><creatorcontrib>Postava, Kamil</creatorcontrib><creatorcontrib>Drévillon, Bernard</creatorcontrib><title>Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry</title><title>European physical journal. Applied physics</title><description>We characterized two samples consisting of photoresist layers on silicon with square arrays of square holes by spectroscopic ellipsometry (SE) and Mueller matrix polarimetry (MMP). Hole lateral dimensions and depths were determined by fitting either SE data taken in conventional planar geometry or MMP data in general conical diffraction configurations. A method for objective determination of the optimal measurement conditions based on sensitivity and parameter correlations is presented.When applied to MMP, this approach showed that for one of the samples the optimal incidence angle was 45◦, much below the widely used 70 degrees value. The robustness of the dimensional characterisation based on MMP is demonstrated by the high stability of the results provided by separated fits of the data taken at different azimuthal angles.</description><subject>Optics</subject><subject>Physics</subject><issn>1286-0042</issn><issn>1286-0050</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqVjrFOAzEQRC1EJAKhpN-WIrA-8MmhQxEoRejoT855Ezby2dbaIO7vORCip5rRzBtplLrSeKPR6FvKR5cfGkSLdnWi5rqx7RLR4Omfv2_O1HkpR0TUrTVzNayFK_cugOeBYuEUC6Q97DiTcPLcw0Fc5Xgo4KmSDBzJw26EkqmvMg0pBM4lDVRlBBc9vLxPEQkMrgp_Qk7BCf_UCzXbu1Do8lcv1PXz0-t6s3xzocsT5GTskuNu87jtvrPpsbGtWX3ou_-wXwc5VbE</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>Foldyna, Martin</creator><creator>de Martino, Antonello</creator><creator>Garcia-Caurel, Enric</creator><creator>Ossikovski, Razvigor</creator><creator>Licitra, C.</creator><creator>Bertin, François</creator><creator>Postava, Kamil</creator><creator>Drévillon, Bernard</creator><general>EDP Sciences</general><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-4309-3310</orcidid><orcidid>https://orcid.org/0000-0001-8413-0504</orcidid><orcidid>https://orcid.org/0000-0002-4309-3310</orcidid><orcidid>https://orcid.org/0000-0001-8413-0504</orcidid></search><sort><creationdate>2008</creationdate><title>Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry</title><author>Foldyna, Martin ; de Martino, Antonello ; Garcia-Caurel, Enric ; Ossikovski, Razvigor ; Licitra, C. ; Bertin, François ; Postava, Kamil ; Drévillon, Bernard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-hal_primary_oai_HAL_hal_00458659v13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Optics</topic><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Foldyna, Martin</creatorcontrib><creatorcontrib>de Martino, Antonello</creatorcontrib><creatorcontrib>Garcia-Caurel, Enric</creatorcontrib><creatorcontrib>Ossikovski, Razvigor</creatorcontrib><creatorcontrib>Licitra, C.</creatorcontrib><creatorcontrib>Bertin, François</creatorcontrib><creatorcontrib>Postava, Kamil</creatorcontrib><creatorcontrib>Drévillon, Bernard</creatorcontrib><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>European physical journal. Applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Foldyna, Martin</au><au>de Martino, Antonello</au><au>Garcia-Caurel, Enric</au><au>Ossikovski, Razvigor</au><au>Licitra, C.</au><au>Bertin, François</au><au>Postava, Kamil</au><au>Drévillon, Bernard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry</atitle><jtitle>European physical journal. Applied physics</jtitle><date>2008</date><risdate>2008</risdate><volume>42</volume><issn>1286-0042</issn><eissn>1286-0050</eissn><abstract>We characterized two samples consisting of photoresist layers on silicon with square arrays of square holes by spectroscopic ellipsometry (SE) and Mueller matrix polarimetry (MMP). Hole lateral dimensions and depths were determined by fitting either SE data taken in conventional planar geometry or MMP data in general conical diffraction configurations. A method for objective determination of the optimal measurement conditions based on sensitivity and parameter correlations is presented.When applied to MMP, this approach showed that for one of the samples the optimal incidence angle was 45◦, much below the widely used 70 degrees value. The robustness of the dimensional characterisation based on MMP is demonstrated by the high stability of the results provided by separated fits of the data taken at different azimuthal angles.</abstract><pub>EDP Sciences</pub><doi>10.1051/epjap:2008089</doi><orcidid>https://orcid.org/0000-0002-4309-3310</orcidid><orcidid>https://orcid.org/0000-0001-8413-0504</orcidid><orcidid>https://orcid.org/0000-0002-4309-3310</orcidid><orcidid>https://orcid.org/0000-0001-8413-0504</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1286-0042 |
ispartof | European physical journal. Applied physics, 2008, Vol.42 |
issn | 1286-0042 1286-0050 |
language | eng |
recordid | cdi_hal_primary_oai_HAL_hal_00458659v1 |
source | Bacon EDP Sciences France Licence nationale-ISTEX-PS-Journals-PFISTEX; EDP Sciences |
subjects | Optics Physics |
title | Critical dimensions of biperiodic gratings determined by spectral ellipsometry and Mueller matrix polarimetry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T14%3A01%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Critical%20dimensions%20of%20biperiodic%20gratings%20determined%20by%20spectral%20ellipsometry%20and%20Mueller%20matrix%20polarimetry&rft.jtitle=European%20physical%20journal.%20Applied%20physics&rft.au=Foldyna,%20Martin&rft.date=2008&rft.volume=42&rft.issn=1286-0042&rft.eissn=1286-0050&rft_id=info:doi/10.1051/epjap:2008089&rft_dat=%3Chal%3Eoai_HAL_hal_00458659v1%3C/hal%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |