Exploration of the X-ray dark-field signal in mineral building materials

Mineral building materials suffer from weathering processes such as salt efflorescence, freeze–thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Blykers, Benjamin, Organista Castelblanco, Caori, Kagias, Matias, Marone, Federica, Stampanoni, Marco, Boone, Matthieu, Cnudde, Veerle, Aelterman, Jan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Blykers, Benjamin
Organista Castelblanco, Caori
Kagias, Matias
Marone, Federica
Stampanoni, Marco
Boone, Matthieu
Cnudde, Veerle
Aelterman, Jan
description Mineral building materials suffer from weathering processes such as salt efflorescence, freeze–thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space properties such as porosity, pore size distribution, and pore connectivity. X-ray computed micro-tomography (µCT) has proven to be a valuable tool to non-destructively investigate the pore space of stone samples in 3D. However, a trade-off between the resolution and field-of-view often impedes reliable conclusions on the material’s properties. X-ray dark-field imaging (DFI) is based on the scattering of X-rays by sub-voxel-sized features, and as such, provides information on the sample complementary to that obtained using conventional µCT. In this manuscript, we apply X-ray dark-field tomography for the first time on four mineral building materials (quartzite, fired clay brick, fired clay roof tile, and carbonated mineral building material), and investigate which information the dark-field signal entails on the sub-resolution space of the sample. Dark-field tomography at multiple length scale sensitivities was performed at the TOMCAT beamline of the Swiss Light Source (Villigen, Switzerland) using a Talbot grating interferometer. The complementary information of the dark-field modality is most clear in the fired clay brick and roof tile; quartz grains that are almost indistinguishable in the conventional µCT scan are clearly visible in the dark-field owing to their low dark-field signal (homogenous sub-voxel structure), whereas the microporous bulk mass has a high dark-field signal. Large (resolved) pores on the other hand, which are clearly visible in the absorption dataset, are almost invisible in the dark-field modality because they are overprinted with dark-field signal originating from the bulk mass. The experiments also showed how the dark-field signal from a feature depends on the length scale sensitivity, which is set by moving the sample with respect to the grating interferometer.
format Article
fullrecord <record><control><sourceid>ghent</sourceid><recordid>TN_cdi_ghent_librecat_oai_archive_ugent_be_8770069</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_archive_ugent_be_8770069</sourcerecordid><originalsourceid>FETCH-ghent_librecat_oai_archive_ugent_be_87700693</originalsourceid><addsrcrecordid>eNqdi0EKwjAQRYMoWLR3yAUCaSPWrqXSA7joLkzttB1NU0lS0dtbwYVrF5_34PEXLEpVosROqWr542sWe3-VUiZ5Oi-PWFk872Z0EGi0fGx56JFXwsGLN-BuoiU0DffUWTCcLB_Iopu1nsg0ZDs-QEBHYPyWrdoZGH-5YempOB9L0fVogzZUO7xA0COQBnfp6YF66j6pRn3IMin3ufrr9AZII0rB</addsrcrecordid><sourcetype>Institutional Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Exploration of the X-ray dark-field signal in mineral building materials</title><source>DOAJ Directory of Open Access Journals</source><source>PubMed Central Open Access</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>Ghent University Academic Bibliography</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Blykers, Benjamin ; Organista Castelblanco, Caori ; Kagias, Matias ; Marone, Federica ; Stampanoni, Marco ; Boone, Matthieu ; Cnudde, Veerle ; Aelterman, Jan</creator><creatorcontrib>Blykers, Benjamin ; Organista Castelblanco, Caori ; Kagias, Matias ; Marone, Federica ; Stampanoni, Marco ; Boone, Matthieu ; Cnudde, Veerle ; Aelterman, Jan</creatorcontrib><description>Mineral building materials suffer from weathering processes such as salt efflorescence, freeze–thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space properties such as porosity, pore size distribution, and pore connectivity. X-ray computed micro-tomography (µCT) has proven to be a valuable tool to non-destructively investigate the pore space of stone samples in 3D. However, a trade-off between the resolution and field-of-view often impedes reliable conclusions on the material’s properties. X-ray dark-field imaging (DFI) is based on the scattering of X-rays by sub-voxel-sized features, and as such, provides information on the sample complementary to that obtained using conventional µCT. In this manuscript, we apply X-ray dark-field tomography for the first time on four mineral building materials (quartzite, fired clay brick, fired clay roof tile, and carbonated mineral building material), and investigate which information the dark-field signal entails on the sub-resolution space of the sample. Dark-field tomography at multiple length scale sensitivities was performed at the TOMCAT beamline of the Swiss Light Source (Villigen, Switzerland) using a Talbot grating interferometer. The complementary information of the dark-field modality is most clear in the fired clay brick and roof tile; quartz grains that are almost indistinguishable in the conventional µCT scan are clearly visible in the dark-field owing to their low dark-field signal (homogenous sub-voxel structure), whereas the microporous bulk mass has a high dark-field signal. Large (resolved) pores on the other hand, which are clearly visible in the absorption dataset, are almost invisible in the dark-field modality because they are overprinted with dark-field signal originating from the bulk mass. The experiments also showed how the dark-field signal from a feature depends on the length scale sensitivity, which is set by moving the sample with respect to the grating interferometer.</description><identifier>ISSN: 2313-433X</identifier><identifier>EISSN: 2313-433X</identifier><language>eng</language><subject>Computer Graphics and Computer-Aided Design ; Computer Vision and Pattern Recognition ; dark-field tomography ; Electrical and Electronic Engineering ; FIBERS ; mineral building materials ; Nuclear Medicine and imaging ; Radiology ; Technology and Engineering ; TOMOGRAPHY ; VISIBILITY-CONTRAST ; X-rays</subject><creationdate>2022</creationdate><rights>Creative Commons Attribution 4.0 International Public License (CC-BY 4.0) info:eu-repo/semantics/openAccess</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,315,780,784,4024,27860</link.rule.ids></links><search><creatorcontrib>Blykers, Benjamin</creatorcontrib><creatorcontrib>Organista Castelblanco, Caori</creatorcontrib><creatorcontrib>Kagias, Matias</creatorcontrib><creatorcontrib>Marone, Federica</creatorcontrib><creatorcontrib>Stampanoni, Marco</creatorcontrib><creatorcontrib>Boone, Matthieu</creatorcontrib><creatorcontrib>Cnudde, Veerle</creatorcontrib><creatorcontrib>Aelterman, Jan</creatorcontrib><title>Exploration of the X-ray dark-field signal in mineral building materials</title><description>Mineral building materials suffer from weathering processes such as salt efflorescence, freeze–thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space properties such as porosity, pore size distribution, and pore connectivity. X-ray computed micro-tomography (µCT) has proven to be a valuable tool to non-destructively investigate the pore space of stone samples in 3D. However, a trade-off between the resolution and field-of-view often impedes reliable conclusions on the material’s properties. X-ray dark-field imaging (DFI) is based on the scattering of X-rays by sub-voxel-sized features, and as such, provides information on the sample complementary to that obtained using conventional µCT. In this manuscript, we apply X-ray dark-field tomography for the first time on four mineral building materials (quartzite, fired clay brick, fired clay roof tile, and carbonated mineral building material), and investigate which information the dark-field signal entails on the sub-resolution space of the sample. Dark-field tomography at multiple length scale sensitivities was performed at the TOMCAT beamline of the Swiss Light Source (Villigen, Switzerland) using a Talbot grating interferometer. The complementary information of the dark-field modality is most clear in the fired clay brick and roof tile; quartz grains that are almost indistinguishable in the conventional µCT scan are clearly visible in the dark-field owing to their low dark-field signal (homogenous sub-voxel structure), whereas the microporous bulk mass has a high dark-field signal. Large (resolved) pores on the other hand, which are clearly visible in the absorption dataset, are almost invisible in the dark-field modality because they are overprinted with dark-field signal originating from the bulk mass. The experiments also showed how the dark-field signal from a feature depends on the length scale sensitivity, which is set by moving the sample with respect to the grating interferometer.</description><subject>Computer Graphics and Computer-Aided Design</subject><subject>Computer Vision and Pattern Recognition</subject><subject>dark-field tomography</subject><subject>Electrical and Electronic Engineering</subject><subject>FIBERS</subject><subject>mineral building materials</subject><subject>Nuclear Medicine and imaging</subject><subject>Radiology</subject><subject>Technology and Engineering</subject><subject>TOMOGRAPHY</subject><subject>VISIBILITY-CONTRAST</subject><subject>X-rays</subject><issn>2313-433X</issn><issn>2313-433X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>ADGLB</sourceid><recordid>eNqdi0EKwjAQRYMoWLR3yAUCaSPWrqXSA7joLkzttB1NU0lS0dtbwYVrF5_34PEXLEpVosROqWr542sWe3-VUiZ5Oi-PWFk872Z0EGi0fGx56JFXwsGLN-BuoiU0DffUWTCcLB_Iopu1nsg0ZDs-QEBHYPyWrdoZGH-5YempOB9L0fVogzZUO7xA0COQBnfp6YF66j6pRn3IMin3ufrr9AZII0rB</recordid><startdate>2022</startdate><enddate>2022</enddate><creator>Blykers, Benjamin</creator><creator>Organista Castelblanco, Caori</creator><creator>Kagias, Matias</creator><creator>Marone, Federica</creator><creator>Stampanoni, Marco</creator><creator>Boone, Matthieu</creator><creator>Cnudde, Veerle</creator><creator>Aelterman, Jan</creator><scope>ADGLB</scope></search><sort><creationdate>2022</creationdate><title>Exploration of the X-ray dark-field signal in mineral building materials</title><author>Blykers, Benjamin ; Organista Castelblanco, Caori ; Kagias, Matias ; Marone, Federica ; Stampanoni, Marco ; Boone, Matthieu ; Cnudde, Veerle ; Aelterman, Jan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ghent_librecat_oai_archive_ugent_be_87700693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Computer Graphics and Computer-Aided Design</topic><topic>Computer Vision and Pattern Recognition</topic><topic>dark-field tomography</topic><topic>Electrical and Electronic Engineering</topic><topic>FIBERS</topic><topic>mineral building materials</topic><topic>Nuclear Medicine and imaging</topic><topic>Radiology</topic><topic>Technology and Engineering</topic><topic>TOMOGRAPHY</topic><topic>VISIBILITY-CONTRAST</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Blykers, Benjamin</creatorcontrib><creatorcontrib>Organista Castelblanco, Caori</creatorcontrib><creatorcontrib>Kagias, Matias</creatorcontrib><creatorcontrib>Marone, Federica</creatorcontrib><creatorcontrib>Stampanoni, Marco</creatorcontrib><creatorcontrib>Boone, Matthieu</creatorcontrib><creatorcontrib>Cnudde, Veerle</creatorcontrib><creatorcontrib>Aelterman, Jan</creatorcontrib><collection>Ghent University Academic Bibliography</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Blykers, Benjamin</au><au>Organista Castelblanco, Caori</au><au>Kagias, Matias</au><au>Marone, Federica</au><au>Stampanoni, Marco</au><au>Boone, Matthieu</au><au>Cnudde, Veerle</au><au>Aelterman, Jan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exploration of the X-ray dark-field signal in mineral building materials</atitle><date>2022</date><risdate>2022</risdate><issn>2313-433X</issn><eissn>2313-433X</eissn><abstract>Mineral building materials suffer from weathering processes such as salt efflorescence, freeze–thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space properties such as porosity, pore size distribution, and pore connectivity. X-ray computed micro-tomography (µCT) has proven to be a valuable tool to non-destructively investigate the pore space of stone samples in 3D. However, a trade-off between the resolution and field-of-view often impedes reliable conclusions on the material’s properties. X-ray dark-field imaging (DFI) is based on the scattering of X-rays by sub-voxel-sized features, and as such, provides information on the sample complementary to that obtained using conventional µCT. In this manuscript, we apply X-ray dark-field tomography for the first time on four mineral building materials (quartzite, fired clay brick, fired clay roof tile, and carbonated mineral building material), and investigate which information the dark-field signal entails on the sub-resolution space of the sample. Dark-field tomography at multiple length scale sensitivities was performed at the TOMCAT beamline of the Swiss Light Source (Villigen, Switzerland) using a Talbot grating interferometer. The complementary information of the dark-field modality is most clear in the fired clay brick and roof tile; quartz grains that are almost indistinguishable in the conventional µCT scan are clearly visible in the dark-field owing to their low dark-field signal (homogenous sub-voxel structure), whereas the microporous bulk mass has a high dark-field signal. Large (resolved) pores on the other hand, which are clearly visible in the absorption dataset, are almost invisible in the dark-field modality because they are overprinted with dark-field signal originating from the bulk mass. The experiments also showed how the dark-field signal from a feature depends on the length scale sensitivity, which is set by moving the sample with respect to the grating interferometer.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2313-433X
ispartof
issn 2313-433X
2313-433X
language eng
recordid cdi_ghent_librecat_oai_archive_ugent_be_8770069
source DOAJ Directory of Open Access Journals; PubMed Central Open Access; MDPI - Multidisciplinary Digital Publishing Institute; Ghent University Academic Bibliography; EZB-FREE-00999 freely available EZB journals; PubMed Central
subjects Computer Graphics and Computer-Aided Design
Computer Vision and Pattern Recognition
dark-field tomography
Electrical and Electronic Engineering
FIBERS
mineral building materials
Nuclear Medicine and imaging
Radiology
Technology and Engineering
TOMOGRAPHY
VISIBILITY-CONTRAST
X-rays
title Exploration of the X-ray dark-field signal in mineral building materials
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T20%3A42%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ghent&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exploration%20of%20the%20X-ray%20dark-field%20signal%20in%20mineral%20building%20materials&rft.au=Blykers,%20Benjamin&rft.date=2022&rft.issn=2313-433X&rft.eissn=2313-433X&rft_id=info:doi/&rft_dat=%3Cghent%3Eoai_archive_ugent_be_8770069%3C/ghent%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true