Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems

This study aimed to assess and evaluate the canal shaping ability of two different Ni-Ti rotary systems, Vortex Blue (VB) and TruNatomy (TN), using micro-computed tomography in extracted premolars. A total of 20 extracted bifurcated maxillary first premolars with two separate canals were randomly di...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Crystals (Basel) 2024-11, Vol.14 (11)
Hauptverfasser: Alghamdi, Batool, Al-Habib, Mey, Alsulaiman, Mona, Bahanan, Lina, Alrahlah, Ali, Bautista, Leonel S. J, Bukhari, Sarah, Howait, Mohammed, Alsofi, Loai
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 11
container_start_page
container_title Crystals (Basel)
container_volume 14
creator Alghamdi, Batool
Al-Habib, Mey
Alsulaiman, Mona
Bahanan, Lina
Alrahlah, Ali
Bautista, Leonel S. J
Bukhari, Sarah
Howait, Mohammed
Alsofi, Loai
description This study aimed to assess and evaluate the canal shaping ability of two different Ni-Ti rotary systems, Vortex Blue (VB) and TruNatomy (TN), using micro-computed tomography in extracted premolars. A total of 20 extracted bifurcated maxillary first premolars with two separate canals were randomly divided into two groups and prepared with either VB 35/0.04 (Dentsply Maillefer, Ballaigues, Switzerland) or TN Medium 36/0.03 (Dentsply Sirona). Pre- and post-instrumentation micro-CT scans were analyzed to measure the following parameters: percentage of untouched canal surface area, changes in canal surface area, changes in canal volume, structural model index (SMI), changes in canal angulation, changes in dentin thickness, transportation, and centering ability. Statistical analysis was performed with a significance level set at p-value < 0.05. Both VB and TN files showed a significant increase in the basic canal geometry parameters including canal surface area and canal volume. Both file systems showed no significant changes in SMI or dentin thickness after canal instrumentation (p > 0.05). Some degree of canal transportation and a similar centering ability ratio with no significant difference were observed in both file systems (p > 0.05). TN files showed less pre-cervical dentin removal when compared to VB files. A significant difference was found in the TN group regarding the dentin removal between coronal and apical thirds (p = 0.03). Both VB and TN files produced comparable root canal preparation with no considerable shaping mishaps and errors. Both files showed minimum canal transportation and minimum straightening of the canal curvature. TN files removed less pre-cervical dentin than apical dentin.
doi_str_mv 10.3390/cryst14110980
format Article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A818107473</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A818107473</galeid><sourcerecordid>A818107473</sourcerecordid><originalsourceid>FETCH-LOGICAL-g152t-dba4240aa00c1bf76bbfea67f1d7263945e829c0e59f759505d3cb9108d7ba1f3</originalsourceid><addsrcrecordid>eNptjs9LwzAUx4MoOOaO3gOeO5OmbdrjHPMHbBNc9SIyXtKki7RNadJh_3sretjB9z28Lx--78tD6JqSOWMZuZXd4DyNKCVZSs7QJCScBRGLw_MTf4lmzn2ScXhCOKcTdNwY2dlgaeu296rAua1t2UF7MBKvjlD14I1tsNXYHxTeHaA1TYkXwlTGDz_4zXZefeG7qlcYmrGg67fgbT28u76d55sPvDVBbvCL9dANeDd-qWp3hS40VE7N_vYUvd6v8uVjsH5-eFou1kFJ49AHhYAojAgAIZIKzRMhtIKEa1rwMGFZFKs0zCRRcaZ5nMUkLpgUGSVpwQVQzabo5re3hErtTaOt70DWxsn9IqUpJTzibEzN_0mNKlRtpG2UNiM_OfgGgl1vaA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems</title><source>MDPI - Multidisciplinary Digital Publishing Institute</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Alghamdi, Batool ; Al-Habib, Mey ; Alsulaiman, Mona ; Bahanan, Lina ; Alrahlah, Ali ; Bautista, Leonel S. J ; Bukhari, Sarah ; Howait, Mohammed ; Alsofi, Loai</creator><creatorcontrib>Alghamdi, Batool ; Al-Habib, Mey ; Alsulaiman, Mona ; Bahanan, Lina ; Alrahlah, Ali ; Bautista, Leonel S. J ; Bukhari, Sarah ; Howait, Mohammed ; Alsofi, Loai</creatorcontrib><description>This study aimed to assess and evaluate the canal shaping ability of two different Ni-Ti rotary systems, Vortex Blue (VB) and TruNatomy (TN), using micro-computed tomography in extracted premolars. A total of 20 extracted bifurcated maxillary first premolars with two separate canals were randomly divided into two groups and prepared with either VB 35/0.04 (Dentsply Maillefer, Ballaigues, Switzerland) or TN Medium 36/0.03 (Dentsply Sirona). Pre- and post-instrumentation micro-CT scans were analyzed to measure the following parameters: percentage of untouched canal surface area, changes in canal surface area, changes in canal volume, structural model index (SMI), changes in canal angulation, changes in dentin thickness, transportation, and centering ability. Statistical analysis was performed with a significance level set at p-value &lt; 0.05. Both VB and TN files showed a significant increase in the basic canal geometry parameters including canal surface area and canal volume. Both file systems showed no significant changes in SMI or dentin thickness after canal instrumentation (p &gt; 0.05). Some degree of canal transportation and a similar centering ability ratio with no significant difference were observed in both file systems (p &gt; 0.05). TN files showed less pre-cervical dentin removal when compared to VB files. A significant difference was found in the TN group regarding the dentin removal between coronal and apical thirds (p = 0.03). Both VB and TN files produced comparable root canal preparation with no considerable shaping mishaps and errors. Both files showed minimum canal transportation and minimum straightening of the canal curvature. TN files removed less pre-cervical dentin than apical dentin.</description><identifier>ISSN: 2073-4352</identifier><identifier>EISSN: 2073-4352</identifier><identifier>DOI: 10.3390/cryst14110980</identifier><language>eng</language><publisher>MDPI AG</publisher><subject>CT imaging ; Ethylenediaminetetraacetic acid ; Root canal therapy</subject><ispartof>Crystals (Basel), 2024-11, Vol.14 (11)</ispartof><rights>COPYRIGHT 2024 MDPI AG</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids></links><search><creatorcontrib>Alghamdi, Batool</creatorcontrib><creatorcontrib>Al-Habib, Mey</creatorcontrib><creatorcontrib>Alsulaiman, Mona</creatorcontrib><creatorcontrib>Bahanan, Lina</creatorcontrib><creatorcontrib>Alrahlah, Ali</creatorcontrib><creatorcontrib>Bautista, Leonel S. J</creatorcontrib><creatorcontrib>Bukhari, Sarah</creatorcontrib><creatorcontrib>Howait, Mohammed</creatorcontrib><creatorcontrib>Alsofi, Loai</creatorcontrib><title>Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems</title><title>Crystals (Basel)</title><description>This study aimed to assess and evaluate the canal shaping ability of two different Ni-Ti rotary systems, Vortex Blue (VB) and TruNatomy (TN), using micro-computed tomography in extracted premolars. A total of 20 extracted bifurcated maxillary first premolars with two separate canals were randomly divided into two groups and prepared with either VB 35/0.04 (Dentsply Maillefer, Ballaigues, Switzerland) or TN Medium 36/0.03 (Dentsply Sirona). Pre- and post-instrumentation micro-CT scans were analyzed to measure the following parameters: percentage of untouched canal surface area, changes in canal surface area, changes in canal volume, structural model index (SMI), changes in canal angulation, changes in dentin thickness, transportation, and centering ability. Statistical analysis was performed with a significance level set at p-value &lt; 0.05. Both VB and TN files showed a significant increase in the basic canal geometry parameters including canal surface area and canal volume. Both file systems showed no significant changes in SMI or dentin thickness after canal instrumentation (p &gt; 0.05). Some degree of canal transportation and a similar centering ability ratio with no significant difference were observed in both file systems (p &gt; 0.05). TN files showed less pre-cervical dentin removal when compared to VB files. A significant difference was found in the TN group regarding the dentin removal between coronal and apical thirds (p = 0.03). Both VB and TN files produced comparable root canal preparation with no considerable shaping mishaps and errors. Both files showed minimum canal transportation and minimum straightening of the canal curvature. TN files removed less pre-cervical dentin than apical dentin.</description><subject>CT imaging</subject><subject>Ethylenediaminetetraacetic acid</subject><subject>Root canal therapy</subject><issn>2073-4352</issn><issn>2073-4352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptjs9LwzAUx4MoOOaO3gOeO5OmbdrjHPMHbBNc9SIyXtKki7RNadJh_3sretjB9z28Lx--78tD6JqSOWMZuZXd4DyNKCVZSs7QJCScBRGLw_MTf4lmzn2ScXhCOKcTdNwY2dlgaeu296rAua1t2UF7MBKvjlD14I1tsNXYHxTeHaA1TYkXwlTGDz_4zXZefeG7qlcYmrGg67fgbT28u76d55sPvDVBbvCL9dANeDd-qWp3hS40VE7N_vYUvd6v8uVjsH5-eFou1kFJ49AHhYAojAgAIZIKzRMhtIKEa1rwMGFZFKs0zCRRcaZ5nMUkLpgUGSVpwQVQzabo5re3hErtTaOt70DWxsn9IqUpJTzibEzN_0mNKlRtpG2UNiM_OfgGgl1vaA</recordid><startdate>20241101</startdate><enddate>20241101</enddate><creator>Alghamdi, Batool</creator><creator>Al-Habib, Mey</creator><creator>Alsulaiman, Mona</creator><creator>Bahanan, Lina</creator><creator>Alrahlah, Ali</creator><creator>Bautista, Leonel S. J</creator><creator>Bukhari, Sarah</creator><creator>Howait, Mohammed</creator><creator>Alsofi, Loai</creator><general>MDPI AG</general><scope/></search><sort><creationdate>20241101</creationdate><title>Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems</title><author>Alghamdi, Batool ; Al-Habib, Mey ; Alsulaiman, Mona ; Bahanan, Lina ; Alrahlah, Ali ; Bautista, Leonel S. J ; Bukhari, Sarah ; Howait, Mohammed ; Alsofi, Loai</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g152t-dba4240aa00c1bf76bbfea67f1d7263945e829c0e59f759505d3cb9108d7ba1f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>CT imaging</topic><topic>Ethylenediaminetetraacetic acid</topic><topic>Root canal therapy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alghamdi, Batool</creatorcontrib><creatorcontrib>Al-Habib, Mey</creatorcontrib><creatorcontrib>Alsulaiman, Mona</creatorcontrib><creatorcontrib>Bahanan, Lina</creatorcontrib><creatorcontrib>Alrahlah, Ali</creatorcontrib><creatorcontrib>Bautista, Leonel S. J</creatorcontrib><creatorcontrib>Bukhari, Sarah</creatorcontrib><creatorcontrib>Howait, Mohammed</creatorcontrib><creatorcontrib>Alsofi, Loai</creatorcontrib><jtitle>Crystals (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alghamdi, Batool</au><au>Al-Habib, Mey</au><au>Alsulaiman, Mona</au><au>Bahanan, Lina</au><au>Alrahlah, Ali</au><au>Bautista, Leonel S. J</au><au>Bukhari, Sarah</au><au>Howait, Mohammed</au><au>Alsofi, Loai</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems</atitle><jtitle>Crystals (Basel)</jtitle><date>2024-11-01</date><risdate>2024</risdate><volume>14</volume><issue>11</issue><issn>2073-4352</issn><eissn>2073-4352</eissn><abstract>This study aimed to assess and evaluate the canal shaping ability of two different Ni-Ti rotary systems, Vortex Blue (VB) and TruNatomy (TN), using micro-computed tomography in extracted premolars. A total of 20 extracted bifurcated maxillary first premolars with two separate canals were randomly divided into two groups and prepared with either VB 35/0.04 (Dentsply Maillefer, Ballaigues, Switzerland) or TN Medium 36/0.03 (Dentsply Sirona). Pre- and post-instrumentation micro-CT scans were analyzed to measure the following parameters: percentage of untouched canal surface area, changes in canal surface area, changes in canal volume, structural model index (SMI), changes in canal angulation, changes in dentin thickness, transportation, and centering ability. Statistical analysis was performed with a significance level set at p-value &lt; 0.05. Both VB and TN files showed a significant increase in the basic canal geometry parameters including canal surface area and canal volume. Both file systems showed no significant changes in SMI or dentin thickness after canal instrumentation (p &gt; 0.05). Some degree of canal transportation and a similar centering ability ratio with no significant difference were observed in both file systems (p &gt; 0.05). TN files showed less pre-cervical dentin removal when compared to VB files. A significant difference was found in the TN group regarding the dentin removal between coronal and apical thirds (p = 0.03). Both VB and TN files produced comparable root canal preparation with no considerable shaping mishaps and errors. Both files showed minimum canal transportation and minimum straightening of the canal curvature. TN files removed less pre-cervical dentin than apical dentin.</abstract><pub>MDPI AG</pub><doi>10.3390/cryst14110980</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2073-4352
ispartof Crystals (Basel), 2024-11, Vol.14 (11)
issn 2073-4352
2073-4352
language eng
recordid cdi_gale_infotracmisc_A818107473
source MDPI - Multidisciplinary Digital Publishing Institute; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects CT imaging
Ethylenediaminetetraacetic acid
Root canal therapy
title Micro-Computed Tomographic Evaluation of the Shaping Ability of Vortex Blue and TruNatomy[sup.TM] Ni-Ti Rotary Systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T20%3A24%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Micro-Computed%20Tomographic%20Evaluation%20of%20the%20Shaping%20Ability%20of%20Vortex%20Blue%20and%20TruNatomy%5Bsup.TM%5D%20Ni-Ti%20Rotary%20Systems&rft.jtitle=Crystals%20(Basel)&rft.au=Alghamdi,%20Batool&rft.date=2024-11-01&rft.volume=14&rft.issue=11&rft.issn=2073-4352&rft.eissn=2073-4352&rft_id=info:doi/10.3390/cryst14110980&rft_dat=%3Cgale%3EA818107473%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A818107473&rfr_iscdi=true