Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing...
Gespeichert in:
Veröffentlicht in: | Applied sciences 2023-09, Vol.13 (18) |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 18 |
container_start_page | |
container_title | Applied sciences |
container_volume | 13 |
creator | Mello, Bruno Freitas De Carvalho Formiga, Marcio Bianchini, Marco Aurélio Borges, Ivan Coura, Gustavo Tumedei, Margherita Fuller, Renato Petrini, Morena Romasco, Tea Vaz, Paula Piattelli, Adriano Di Pietro, Natalia |
description | Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing chambers, which create empty spaces between the implant and peri-implant bone, helps reduce the risk of compressive bone necrosis. High Insertion Torque (IT) values could potentially lead to the deterioration of the implant-abutment connection. However, the optimal implant macro-structure and IT values remain unknown. In this study, implants with healing chambers (Test) and without (Control) were inserted into polyurethane blocks with densities of 10, 20, 30, and 40 pounds per cubic foot (PCF). In blocks with densities of 30 and 40 PCF, Control implants had significantly higher IT values than Test implants. Additionally, Control implants exhibited significantly higher Removal Torque (RT) values than Test implants, but only in the 30 PCF density block (p < 0.0001). However, no differences were found between the implants in the 10, 20, and 40 PCF density blocks. Similarly, no significant differences were observed in the Implant Stability Quotient (ISQ) values between the Test and Control implants. The results of the present study confirm that adding healing chambers to the macro-structure of dental implants can significantly reduce IT values without affecting ISQ values. This suggests the potential for avoiding compression and damage to peri-implant bone while maintaining consistent levels of PS. |
doi_str_mv | 10.3390/app131810215 |
format | Article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A766925241</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A766925241</galeid><sourcerecordid>A766925241</sourcerecordid><originalsourceid>FETCH-LOGICAL-g671-894cbff0d3fcad389454e049e05e52444e9fe685a8c788319564ec4f34c592ee3</originalsourceid><addsrcrecordid>eNptjEFLAzEQhYMoWGpv_oCA563JJtndeFuqtgsFBYvXkmYnbWQ3qZss0n9vUA89OHN4b4bvPYRuKZkzJsm9Oh4poxUlORUXaJKTssgYp-Xlmb9GsxA-SBpJWUInyDcuwBCtd3jjh88RcB0ChNCDi9g6_JhUdbjpj51yMeAvGw9YufbH-DHiFajOuj1eHFS_gyE84Bq_-u40DhAPygFuHH63cfD4LY7t6QZdGdUFmP3pFG2enzaLVbZ-WTaLep3ti5JmleR6ZwxpmdGqZekUHAiXQASInHMO0kBRCVXpsqoYlaLgoLlhXAuZA7Apuvut3asOttYZHwelexv0ti6LQuaphSZq_g-VtoXeau_A2PQ_C3wDqgNrng</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>MDPI - Multidisciplinary Digital Publishing Institute</source><creator>Mello, Bruno Freitas ; De Carvalho Formiga, Marcio ; Bianchini, Marco Aurélio ; Borges, Ivan ; Coura, Gustavo ; Tumedei, Margherita ; Fuller, Renato ; Petrini, Morena ; Romasco, Tea ; Vaz, Paula ; Piattelli, Adriano ; Di Pietro, Natalia</creator><creatorcontrib>Mello, Bruno Freitas ; De Carvalho Formiga, Marcio ; Bianchini, Marco Aurélio ; Borges, Ivan ; Coura, Gustavo ; Tumedei, Margherita ; Fuller, Renato ; Petrini, Morena ; Romasco, Tea ; Vaz, Paula ; Piattelli, Adriano ; Di Pietro, Natalia</creatorcontrib><description>Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing chambers, which create empty spaces between the implant and peri-implant bone, helps reduce the risk of compressive bone necrosis. High Insertion Torque (IT) values could potentially lead to the deterioration of the implant-abutment connection. However, the optimal implant macro-structure and IT values remain unknown. In this study, implants with healing chambers (Test) and without (Control) were inserted into polyurethane blocks with densities of 10, 20, 30, and 40 pounds per cubic foot (PCF). In blocks with densities of 30 and 40 PCF, Control implants had significantly higher IT values than Test implants. Additionally, Control implants exhibited significantly higher Removal Torque (RT) values than Test implants, but only in the 30 PCF density block (p < 0.0001). However, no differences were found between the implants in the 10, 20, and 40 PCF density blocks. Similarly, no significant differences were observed in the Implant Stability Quotient (ISQ) values between the Test and Control implants. The results of the present study confirm that adding healing chambers to the macro-structure of dental implants can significantly reduce IT values without affecting ISQ values. This suggests the potential for avoiding compression and damage to peri-implant bone while maintaining consistent levels of PS.</description><identifier>ISSN: 2076-3417</identifier><identifier>EISSN: 2076-3417</identifier><identifier>DOI: 10.3390/app131810215</identifier><language>eng</language><publisher>MDPI AG</publisher><subject>Bones ; Density ; Implant dentures ; Polyurethanes</subject><ispartof>Applied sciences, 2023-09, Vol.13 (18)</ispartof><rights>COPYRIGHT 2023 MDPI AG</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27923,27924</link.rule.ids></links><search><creatorcontrib>Mello, Bruno Freitas</creatorcontrib><creatorcontrib>De Carvalho Formiga, Marcio</creatorcontrib><creatorcontrib>Bianchini, Marco Aurélio</creatorcontrib><creatorcontrib>Borges, Ivan</creatorcontrib><creatorcontrib>Coura, Gustavo</creatorcontrib><creatorcontrib>Tumedei, Margherita</creatorcontrib><creatorcontrib>Fuller, Renato</creatorcontrib><creatorcontrib>Petrini, Morena</creatorcontrib><creatorcontrib>Romasco, Tea</creatorcontrib><creatorcontrib>Vaz, Paula</creatorcontrib><creatorcontrib>Piattelli, Adriano</creatorcontrib><creatorcontrib>Di Pietro, Natalia</creatorcontrib><title>Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study</title><title>Applied sciences</title><description>Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing chambers, which create empty spaces between the implant and peri-implant bone, helps reduce the risk of compressive bone necrosis. High Insertion Torque (IT) values could potentially lead to the deterioration of the implant-abutment connection. However, the optimal implant macro-structure and IT values remain unknown. In this study, implants with healing chambers (Test) and without (Control) were inserted into polyurethane blocks with densities of 10, 20, 30, and 40 pounds per cubic foot (PCF). In blocks with densities of 30 and 40 PCF, Control implants had significantly higher IT values than Test implants. Additionally, Control implants exhibited significantly higher Removal Torque (RT) values than Test implants, but only in the 30 PCF density block (p < 0.0001). However, no differences were found between the implants in the 10, 20, and 40 PCF density blocks. Similarly, no significant differences were observed in the Implant Stability Quotient (ISQ) values between the Test and Control implants. The results of the present study confirm that adding healing chambers to the macro-structure of dental implants can significantly reduce IT values without affecting ISQ values. This suggests the potential for avoiding compression and damage to peri-implant bone while maintaining consistent levels of PS.</description><subject>Bones</subject><subject>Density</subject><subject>Implant dentures</subject><subject>Polyurethanes</subject><issn>2076-3417</issn><issn>2076-3417</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptjEFLAzEQhYMoWGpv_oCA563JJtndeFuqtgsFBYvXkmYnbWQ3qZss0n9vUA89OHN4b4bvPYRuKZkzJsm9Oh4poxUlORUXaJKTssgYp-Xlmb9GsxA-SBpJWUInyDcuwBCtd3jjh88RcB0ChNCDi9g6_JhUdbjpj51yMeAvGw9YufbH-DHiFajOuj1eHFS_gyE84Bq_-u40DhAPygFuHH63cfD4LY7t6QZdGdUFmP3pFG2enzaLVbZ-WTaLep3ti5JmleR6ZwxpmdGqZekUHAiXQASInHMO0kBRCVXpsqoYlaLgoLlhXAuZA7Apuvut3asOttYZHwelexv0ti6LQuaphSZq_g-VtoXeau_A2PQ_C3wDqgNrng</recordid><startdate>20230901</startdate><enddate>20230901</enddate><creator>Mello, Bruno Freitas</creator><creator>De Carvalho Formiga, Marcio</creator><creator>Bianchini, Marco Aurélio</creator><creator>Borges, Ivan</creator><creator>Coura, Gustavo</creator><creator>Tumedei, Margherita</creator><creator>Fuller, Renato</creator><creator>Petrini, Morena</creator><creator>Romasco, Tea</creator><creator>Vaz, Paula</creator><creator>Piattelli, Adriano</creator><creator>Di Pietro, Natalia</creator><general>MDPI AG</general><scope/></search><sort><creationdate>20230901</creationdate><title>Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study</title><author>Mello, Bruno Freitas ; De Carvalho Formiga, Marcio ; Bianchini, Marco Aurélio ; Borges, Ivan ; Coura, Gustavo ; Tumedei, Margherita ; Fuller, Renato ; Petrini, Morena ; Romasco, Tea ; Vaz, Paula ; Piattelli, Adriano ; Di Pietro, Natalia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g671-894cbff0d3fcad389454e049e05e52444e9fe685a8c788319564ec4f34c592ee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Bones</topic><topic>Density</topic><topic>Implant dentures</topic><topic>Polyurethanes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mello, Bruno Freitas</creatorcontrib><creatorcontrib>De Carvalho Formiga, Marcio</creatorcontrib><creatorcontrib>Bianchini, Marco Aurélio</creatorcontrib><creatorcontrib>Borges, Ivan</creatorcontrib><creatorcontrib>Coura, Gustavo</creatorcontrib><creatorcontrib>Tumedei, Margherita</creatorcontrib><creatorcontrib>Fuller, Renato</creatorcontrib><creatorcontrib>Petrini, Morena</creatorcontrib><creatorcontrib>Romasco, Tea</creatorcontrib><creatorcontrib>Vaz, Paula</creatorcontrib><creatorcontrib>Piattelli, Adriano</creatorcontrib><creatorcontrib>Di Pietro, Natalia</creatorcontrib><jtitle>Applied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mello, Bruno Freitas</au><au>De Carvalho Formiga, Marcio</au><au>Bianchini, Marco Aurélio</au><au>Borges, Ivan</au><au>Coura, Gustavo</au><au>Tumedei, Margherita</au><au>Fuller, Renato</au><au>Petrini, Morena</au><au>Romasco, Tea</au><au>Vaz, Paula</au><au>Piattelli, Adriano</au><au>Di Pietro, Natalia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study</atitle><jtitle>Applied sciences</jtitle><date>2023-09-01</date><risdate>2023</risdate><volume>13</volume><issue>18</issue><issn>2076-3417</issn><eissn>2076-3417</eissn><abstract>Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing chambers, which create empty spaces between the implant and peri-implant bone, helps reduce the risk of compressive bone necrosis. High Insertion Torque (IT) values could potentially lead to the deterioration of the implant-abutment connection. However, the optimal implant macro-structure and IT values remain unknown. In this study, implants with healing chambers (Test) and without (Control) were inserted into polyurethane blocks with densities of 10, 20, 30, and 40 pounds per cubic foot (PCF). In blocks with densities of 30 and 40 PCF, Control implants had significantly higher IT values than Test implants. Additionally, Control implants exhibited significantly higher Removal Torque (RT) values than Test implants, but only in the 30 PCF density block (p < 0.0001). However, no differences were found between the implants in the 10, 20, and 40 PCF density blocks. Similarly, no significant differences were observed in the Implant Stability Quotient (ISQ) values between the Test and Control implants. The results of the present study confirm that adding healing chambers to the macro-structure of dental implants can significantly reduce IT values without affecting ISQ values. This suggests the potential for avoiding compression and damage to peri-implant bone while maintaining consistent levels of PS.</abstract><pub>MDPI AG</pub><doi>10.3390/app131810215</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2076-3417 |
ispartof | Applied sciences, 2023-09, Vol.13 (18) |
issn | 2076-3417 2076-3417 |
language | eng |
recordid | cdi_gale_infotracmisc_A766925241 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; MDPI - Multidisciplinary Digital Publishing Institute |
subjects | Bones Density Implant dentures Polyurethanes |
title | Insertion Torque Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T22%3A22%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Insertion%20Torque%20Assessment%20in%20Dental%20Implants%20with%20and%20without%20Healing%20Chambers:%20A%20Polyurethane%20In%20Vitro%20Study&rft.jtitle=Applied%20sciences&rft.au=Mello,%20Bruno%20Freitas&rft.date=2023-09-01&rft.volume=13&rft.issue=18&rft.issn=2076-3417&rft.eissn=2076-3417&rft_id=info:doi/10.3390/app131810215&rft_dat=%3Cgale%3EA766925241%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A766925241&rfr_iscdi=true |