Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada

The aim of this study was to examine the prevalence, location and morphology of maxillary sinus septa, and in particular sagittally orientated forms, which cannot be visualized by classic 2D x-rays. Thereby authors would like to provide information about the potential patient group, to be referred f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of morphology 2015-03, Vol.33 (1), p.144
Hauptverfasser: Malec, Magdalena, Smektala, Tomasz, Tutak, Marcin, Trybek, Grzegorz, Sporniak-Tutak, Katarzyna
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page 144
container_title International journal of morphology
container_volume 33
creator Malec, Magdalena
Smektala, Tomasz
Tutak, Marcin
Trybek, Grzegorz
Sporniak-Tutak, Katarzyna
description The aim of this study was to examine the prevalence, location and morphology of maxillary sinus septa, and in particular sagittally orientated forms, which cannot be visualized by classic 2D x-rays. Thereby authors would like to provide information about the potential patient group, to be referred for the computed tomography scan before sinus lift procedure. The analysis was based on 216 computed tomography archival images. The exclusion criterion was occurrence of any suspected pathology in the maxillary region. The septa prevalence that was investigated in computed tomography was high (49%) with the mean height of 5.44 mm. The incidence of sagittally orientated septa as a challenge in 2D x-rays was 10%, with the second molar region as the most frequent location. Based on the obtained results and radiation safety principles, the authors suggest that orthopantomogram x-ray may be a sufficient ancillary radiological examination before beginning preimplant surgical procedure in the area of the maxillary sinus.
format Article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A535235262</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A535235262</galeid><sourcerecordid>A535235262</sourcerecordid><originalsourceid>FETCH-gale_infotracmisc_A5352352623</originalsourceid><addsrcrecordid>eNqNjt1Kw0AQhfdCwfrzDgNeR2NCGryspcWbgtDelyG7SUc2O2EnEbdv55u5iW2vhYH54XznzJWapeVLmbzm8_JG3Yp8pmlWlGkxUz8b_CZr0QfYkhsEtqbrET68-UJrXGUAnYYN--7AlpuQLLntht5o2HHLjcfuEOANJR4WDm0QkucLTAhhZOsRjYs2dvLn0-QYpnj0TxNNkR7NUDMYByvpB00sUX1Oq6PL3wdR4-mIGu_VdY1WzMOp36nH9Wq3fE-a-MOeXM29x6olqfaLIi-yWPMs_5_qF-pqZ9c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Malec, Magdalena ; Smektala, Tomasz ; Tutak, Marcin ; Trybek, Grzegorz ; Sporniak-Tutak, Katarzyna</creator><creatorcontrib>Malec, Magdalena ; Smektala, Tomasz ; Tutak, Marcin ; Trybek, Grzegorz ; Sporniak-Tutak, Katarzyna</creatorcontrib><description>The aim of this study was to examine the prevalence, location and morphology of maxillary sinus septa, and in particular sagittally orientated forms, which cannot be visualized by classic 2D x-rays. Thereby authors would like to provide information about the potential patient group, to be referred for the computed tomography scan before sinus lift procedure. The analysis was based on 216 computed tomography archival images. The exclusion criterion was occurrence of any suspected pathology in the maxillary region. The septa prevalence that was investigated in computed tomography was high (49%) with the mean height of 5.44 mm. The incidence of sagittally orientated septa as a challenge in 2D x-rays was 10%, with the second molar region as the most frequent location. Based on the obtained results and radiation safety principles, the authors suggest that orthopantomogram x-ray may be a sufficient ancillary radiological examination before beginning preimplant surgical procedure in the area of the maxillary sinus.</description><identifier>ISSN: 0717-9367</identifier><language>spa</language><publisher>Universidad de La Frontera, Facultad de Medicina</publisher><subject>CAT scans ; Dental implants</subject><ispartof>International journal of morphology, 2015-03, Vol.33 (1), p.144</ispartof><rights>COPYRIGHT 2015 Universidad de La Frontera, Facultad de Medicina</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Malec, Magdalena</creatorcontrib><creatorcontrib>Smektala, Tomasz</creatorcontrib><creatorcontrib>Tutak, Marcin</creatorcontrib><creatorcontrib>Trybek, Grzegorz</creatorcontrib><creatorcontrib>Sporniak-Tutak, Katarzyna</creatorcontrib><title>Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada</title><title>International journal of morphology</title><description>The aim of this study was to examine the prevalence, location and morphology of maxillary sinus septa, and in particular sagittally orientated forms, which cannot be visualized by classic 2D x-rays. Thereby authors would like to provide information about the potential patient group, to be referred for the computed tomography scan before sinus lift procedure. The analysis was based on 216 computed tomography archival images. The exclusion criterion was occurrence of any suspected pathology in the maxillary region. The septa prevalence that was investigated in computed tomography was high (49%) with the mean height of 5.44 mm. The incidence of sagittally orientated septa as a challenge in 2D x-rays was 10%, with the second molar region as the most frequent location. Based on the obtained results and radiation safety principles, the authors suggest that orthopantomogram x-ray may be a sufficient ancillary radiological examination before beginning preimplant surgical procedure in the area of the maxillary sinus.</description><subject>CAT scans</subject><subject>Dental implants</subject><issn>0717-9367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqNjt1Kw0AQhfdCwfrzDgNeR2NCGryspcWbgtDelyG7SUc2O2EnEbdv55u5iW2vhYH54XznzJWapeVLmbzm8_JG3Yp8pmlWlGkxUz8b_CZr0QfYkhsEtqbrET68-UJrXGUAnYYN--7AlpuQLLntht5o2HHLjcfuEOANJR4WDm0QkucLTAhhZOsRjYs2dvLn0-QYpnj0TxNNkR7NUDMYByvpB00sUX1Oq6PL3wdR4-mIGu_VdY1WzMOp36nH9Wq3fE-a-MOeXM29x6olqfaLIi-yWPMs_5_qF-pqZ9c</recordid><startdate>20150301</startdate><enddate>20150301</enddate><creator>Malec, Magdalena</creator><creator>Smektala, Tomasz</creator><creator>Tutak, Marcin</creator><creator>Trybek, Grzegorz</creator><creator>Sporniak-Tutak, Katarzyna</creator><general>Universidad de La Frontera, Facultad de Medicina</general><scope>INF</scope></search><sort><creationdate>20150301</creationdate><title>Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada</title><author>Malec, Magdalena ; Smektala, Tomasz ; Tutak, Marcin ; Trybek, Grzegorz ; Sporniak-Tutak, Katarzyna</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-gale_infotracmisc_A5352352623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2015</creationdate><topic>CAT scans</topic><topic>Dental implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Malec, Magdalena</creatorcontrib><creatorcontrib>Smektala, Tomasz</creatorcontrib><creatorcontrib>Tutak, Marcin</creatorcontrib><creatorcontrib>Trybek, Grzegorz</creatorcontrib><creatorcontrib>Sporniak-Tutak, Katarzyna</creatorcontrib><collection>Gale OneFile: Informe Academico</collection><jtitle>International journal of morphology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Malec, Magdalena</au><au>Smektala, Tomasz</au><au>Tutak, Marcin</au><au>Trybek, Grzegorz</au><au>Sporniak-Tutak, Katarzyna</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada</atitle><jtitle>International journal of morphology</jtitle><date>2015-03-01</date><risdate>2015</risdate><volume>33</volume><issue>1</issue><spage>144</spage><pages>144-</pages><issn>0717-9367</issn><abstract>The aim of this study was to examine the prevalence, location and morphology of maxillary sinus septa, and in particular sagittally orientated forms, which cannot be visualized by classic 2D x-rays. Thereby authors would like to provide information about the potential patient group, to be referred for the computed tomography scan before sinus lift procedure. The analysis was based on 216 computed tomography archival images. The exclusion criterion was occurrence of any suspected pathology in the maxillary region. The septa prevalence that was investigated in computed tomography was high (49%) with the mean height of 5.44 mm. The incidence of sagittally orientated septa as a challenge in 2D x-rays was 10%, with the second molar region as the most frequent location. Based on the obtained results and radiation safety principles, the authors suggest that orthopantomogram x-ray may be a sufficient ancillary radiological examination before beginning preimplant surgical procedure in the area of the maxillary sinus.</abstract><pub>Universidad de La Frontera, Facultad de Medicina</pub></addata></record>
fulltext fulltext
identifier ISSN: 0717-9367
ispartof International journal of morphology, 2015-03, Vol.33 (1), p.144
issn 0717-9367
language spa
recordid cdi_gale_infotracmisc_A535235262
source EZB-FREE-00999 freely available EZB journals
subjects CAT scans
Dental implants
title Maxillary Sinus Septa Prevalence and Morphology-Computed Tomography Based Analysis/Prevalencia y Morfologia del Septo del Seno Maxilar. Analisis Basado en Estudios de Tomografia Computadorizada
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T20%3A54%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Maxillary%20Sinus%20Septa%20Prevalence%20and%20Morphology-Computed%20Tomography%20Based%20Analysis/Prevalencia%20y%20Morfologia%20del%20Septo%20del%20Seno%20Maxilar.%20Analisis%20Basado%20en%20Estudios%20de%20Tomografia%20Computadorizada&rft.jtitle=International%20journal%20of%20morphology&rft.au=Malec,%20Magdalena&rft.date=2015-03-01&rft.volume=33&rft.issue=1&rft.spage=144&rft.pages=144-&rft.issn=0717-9367&rft_id=info:doi/&rft_dat=%3Cgale%3EA535235262%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A535235262&rfr_iscdi=true