Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas

•3 full-scale reverse cyclic tests on 3 hollow clay brick masonry infills.•Seismic performance of thin layer of mortar coating connected to both the RC frame and the infilled panel.•Significant improvement of both lateral stiffness and masonry resistance.•Need of reducing shear sliding along the mas...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Construction & building materials 2018-01, Vol.160, p.574-587
Hauptverfasser: Facconi, Luca, Minelli, Fausto, Giuriani, Ezio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 587
container_issue
container_start_page 574
container_title Construction & building materials
container_volume 160
creator Facconi, Luca
Minelli, Fausto
Giuriani, Ezio
description •3 full-scale reverse cyclic tests on 3 hollow clay brick masonry infills.•Seismic performance of thin layer of mortar coating connected to both the RC frame and the infilled panel.•Significant improvement of both lateral stiffness and masonry resistance.•Need of reducing shear sliding along the masonry panel-RC frame interface. A significant number of Infilled Reinforce Concrete (RC) frame structures constructed worldwide are not designed to withstand seismic actions. An important contribution to the lateral resistance of the bare frame is usually provided by weak masonry infills, whose interaction with the frame has been frequently neglected by designers. In case low-rise buildings placed in low seismicity areas are considered, the moderate inelastic demand resulting from the seismic excitation allows implementing retrofitting techniques aiming at improving the structure resistance rather than its ability to dissipate energy by inelastic mechanisms. This paper studies a retrofitting approach aiming at exploiting the frame-to-infill interaction by using a thin layer of mortar coating connected to the outer surfaces of the perimeter walls of the RC buildings. The coating is applied on the existent plaster and is reinforced with an Alkali-Resistant glass fiber mesh properly anchored to the infill. A series of reverse cyclic tests on three hollow clay brick masonry infills, including a not strengthened wall as well as a strengthened and a repaired specimen, was carried out. A special RC frame provided with steel hinges at the columns edges was built to simulate flexural mechanisms generally occurring in weakly reinforced frames. Results proved the ability of the adopted technique to significantly improve both lateral stiffness and resistance of infills. However, the observed behavior suggested future improvements that may lead to a further increment of the infill capacity.
doi_str_mv 10.1016/j.conbuildmat.2017.11.033
format Article
fullrecord <record><control><sourceid>gale_cross</sourceid><recordid>TN_cdi_gale_infotracmisc_A528328246</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A528328246</galeid><els_id>S0950061817322456</els_id><sourcerecordid>A528328246</sourcerecordid><originalsourceid>FETCH-LOGICAL-c463t-4e479250596d59c69224f774882e18b79143e848195167baa9877728daf71f6c3</originalsourceid><addsrcrecordid>eNqNkVuL2zAQhUVpoWna_6DS19qVZFuXxyX0BguFpX0WsjxKJtjWIikt-fdVSB92IQ9lQAPiO0ejOYS856zljMtPx9bHdTzhPC2utIJx1XLesq57QTZcK9OwQciXZMPMwBomuX5N3uR8ZIxJIcWGnB8gP8Y1A42B4hpwnmGiDzsaklsg0wQlxYCl1Ns_WA7UUQ8LrAULxlOmAUdITSUPFa36mHwlfXQF1301pEucILkCNAPmBT2WM3UJXH5LXgU3Z3j3r2_Jry-ff-6-Nfc_vn7f3d03vpddaXrolREDG4ycBuOlEaIPSvVaC-B6VIb3HeheczNwqUbnjFZKCT25oHiQvtuSD1ffvZvBXkYsyfkFs7d3g9Cd0KI-tCXNDWoPax1-jivUxcBzvr3B15qgfvKm4OMTwXjKuEKuR8b9oeS9O-X8HDdX3KeYc4JgHxMuLp0tZ_aSvD3aJ8nbS_KWc1uTr9rdVQt1rb8Rks0eYa3BYAJf7BTxP1z-Aos5vL8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Facconi, Luca ; Minelli, Fausto ; Giuriani, Ezio</creator><creatorcontrib>Facconi, Luca ; Minelli, Fausto ; Giuriani, Ezio</creatorcontrib><description>•3 full-scale reverse cyclic tests on 3 hollow clay brick masonry infills.•Seismic performance of thin layer of mortar coating connected to both the RC frame and the infilled panel.•Significant improvement of both lateral stiffness and masonry resistance.•Need of reducing shear sliding along the masonry panel-RC frame interface. A significant number of Infilled Reinforce Concrete (RC) frame structures constructed worldwide are not designed to withstand seismic actions. An important contribution to the lateral resistance of the bare frame is usually provided by weak masonry infills, whose interaction with the frame has been frequently neglected by designers. In case low-rise buildings placed in low seismicity areas are considered, the moderate inelastic demand resulting from the seismic excitation allows implementing retrofitting techniques aiming at improving the structure resistance rather than its ability to dissipate energy by inelastic mechanisms. This paper studies a retrofitting approach aiming at exploiting the frame-to-infill interaction by using a thin layer of mortar coating connected to the outer surfaces of the perimeter walls of the RC buildings. The coating is applied on the existent plaster and is reinforced with an Alkali-Resistant glass fiber mesh properly anchored to the infill. A series of reverse cyclic tests on three hollow clay brick masonry infills, including a not strengthened wall as well as a strengthened and a repaired specimen, was carried out. A special RC frame provided with steel hinges at the columns edges was built to simulate flexural mechanisms generally occurring in weakly reinforced frames. Results proved the ability of the adopted technique to significantly improve both lateral stiffness and resistance of infills. However, the observed behavior suggested future improvements that may lead to a further increment of the infill capacity.</description><identifier>ISSN: 0950-0618</identifier><identifier>EISSN: 1879-0526</identifier><identifier>DOI: 10.1016/j.conbuildmat.2017.11.033</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Analysis ; Cyclic tests ; Glass fibre mesh ; Hollow clay bricks ; Masonry infills ; Mechanical properties ; Mortar coating ; Reinforced concrete ; Retrofitting</subject><ispartof>Construction &amp; building materials, 2018-01, Vol.160, p.574-587</ispartof><rights>2017 Elsevier Ltd</rights><rights>COPYRIGHT 2018 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c463t-4e479250596d59c69224f774882e18b79143e848195167baa9877728daf71f6c3</citedby><cites>FETCH-LOGICAL-c463t-4e479250596d59c69224f774882e18b79143e848195167baa9877728daf71f6c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.conbuildmat.2017.11.033$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Facconi, Luca</creatorcontrib><creatorcontrib>Minelli, Fausto</creatorcontrib><creatorcontrib>Giuriani, Ezio</creatorcontrib><title>Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas</title><title>Construction &amp; building materials</title><description>•3 full-scale reverse cyclic tests on 3 hollow clay brick masonry infills.•Seismic performance of thin layer of mortar coating connected to both the RC frame and the infilled panel.•Significant improvement of both lateral stiffness and masonry resistance.•Need of reducing shear sliding along the masonry panel-RC frame interface. A significant number of Infilled Reinforce Concrete (RC) frame structures constructed worldwide are not designed to withstand seismic actions. An important contribution to the lateral resistance of the bare frame is usually provided by weak masonry infills, whose interaction with the frame has been frequently neglected by designers. In case low-rise buildings placed in low seismicity areas are considered, the moderate inelastic demand resulting from the seismic excitation allows implementing retrofitting techniques aiming at improving the structure resistance rather than its ability to dissipate energy by inelastic mechanisms. This paper studies a retrofitting approach aiming at exploiting the frame-to-infill interaction by using a thin layer of mortar coating connected to the outer surfaces of the perimeter walls of the RC buildings. The coating is applied on the existent plaster and is reinforced with an Alkali-Resistant glass fiber mesh properly anchored to the infill. A series of reverse cyclic tests on three hollow clay brick masonry infills, including a not strengthened wall as well as a strengthened and a repaired specimen, was carried out. A special RC frame provided with steel hinges at the columns edges was built to simulate flexural mechanisms generally occurring in weakly reinforced frames. Results proved the ability of the adopted technique to significantly improve both lateral stiffness and resistance of infills. However, the observed behavior suggested future improvements that may lead to a further increment of the infill capacity.</description><subject>Analysis</subject><subject>Cyclic tests</subject><subject>Glass fibre mesh</subject><subject>Hollow clay bricks</subject><subject>Masonry infills</subject><subject>Mechanical properties</subject><subject>Mortar coating</subject><subject>Reinforced concrete</subject><subject>Retrofitting</subject><issn>0950-0618</issn><issn>1879-0526</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>N95</sourceid><recordid>eNqNkVuL2zAQhUVpoWna_6DS19qVZFuXxyX0BguFpX0WsjxKJtjWIikt-fdVSB92IQ9lQAPiO0ejOYS856zljMtPx9bHdTzhPC2utIJx1XLesq57QTZcK9OwQciXZMPMwBomuX5N3uR8ZIxJIcWGnB8gP8Y1A42B4hpwnmGiDzsaklsg0wQlxYCl1Ns_WA7UUQ8LrAULxlOmAUdITSUPFa36mHwlfXQF1301pEucILkCNAPmBT2WM3UJXH5LXgU3Z3j3r2_Jry-ff-6-Nfc_vn7f3d03vpddaXrolREDG4ycBuOlEaIPSvVaC-B6VIb3HeheczNwqUbnjFZKCT25oHiQvtuSD1ffvZvBXkYsyfkFs7d3g9Cd0KI-tCXNDWoPax1-jivUxcBzvr3B15qgfvKm4OMTwXjKuEKuR8b9oeS9O-X8HDdX3KeYc4JgHxMuLp0tZ_aSvD3aJ8nbS_KWc1uTr9rdVQt1rb8Rks0eYa3BYAJf7BTxP1z-Aos5vL8</recordid><startdate>20180130</startdate><enddate>20180130</enddate><creator>Facconi, Luca</creator><creator>Minelli, Fausto</creator><creator>Giuriani, Ezio</creator><general>Elsevier Ltd</general><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>N95</scope><scope>XI7</scope></search><sort><creationdate>20180130</creationdate><title>Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas</title><author>Facconi, Luca ; Minelli, Fausto ; Giuriani, Ezio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c463t-4e479250596d59c69224f774882e18b79143e848195167baa9877728daf71f6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Analysis</topic><topic>Cyclic tests</topic><topic>Glass fibre mesh</topic><topic>Hollow clay bricks</topic><topic>Masonry infills</topic><topic>Mechanical properties</topic><topic>Mortar coating</topic><topic>Reinforced concrete</topic><topic>Retrofitting</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Facconi, Luca</creatorcontrib><creatorcontrib>Minelli, Fausto</creatorcontrib><creatorcontrib>Giuriani, Ezio</creatorcontrib><collection>CrossRef</collection><collection>Gale Business: Insights (formerly Business Insights: Global)</collection><collection>Business Insights: Essentials</collection><jtitle>Construction &amp; building materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Facconi, Luca</au><au>Minelli, Fausto</au><au>Giuriani, Ezio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas</atitle><jtitle>Construction &amp; building materials</jtitle><date>2018-01-30</date><risdate>2018</risdate><volume>160</volume><spage>574</spage><epage>587</epage><pages>574-587</pages><issn>0950-0618</issn><eissn>1879-0526</eissn><abstract>•3 full-scale reverse cyclic tests on 3 hollow clay brick masonry infills.•Seismic performance of thin layer of mortar coating connected to both the RC frame and the infilled panel.•Significant improvement of both lateral stiffness and masonry resistance.•Need of reducing shear sliding along the masonry panel-RC frame interface. A significant number of Infilled Reinforce Concrete (RC) frame structures constructed worldwide are not designed to withstand seismic actions. An important contribution to the lateral resistance of the bare frame is usually provided by weak masonry infills, whose interaction with the frame has been frequently neglected by designers. In case low-rise buildings placed in low seismicity areas are considered, the moderate inelastic demand resulting from the seismic excitation allows implementing retrofitting techniques aiming at improving the structure resistance rather than its ability to dissipate energy by inelastic mechanisms. This paper studies a retrofitting approach aiming at exploiting the frame-to-infill interaction by using a thin layer of mortar coating connected to the outer surfaces of the perimeter walls of the RC buildings. The coating is applied on the existent plaster and is reinforced with an Alkali-Resistant glass fiber mesh properly anchored to the infill. A series of reverse cyclic tests on three hollow clay brick masonry infills, including a not strengthened wall as well as a strengthened and a repaired specimen, was carried out. A special RC frame provided with steel hinges at the columns edges was built to simulate flexural mechanisms generally occurring in weakly reinforced frames. Results proved the ability of the adopted technique to significantly improve both lateral stiffness and resistance of infills. However, the observed behavior suggested future improvements that may lead to a further increment of the infill capacity.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.conbuildmat.2017.11.033</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0950-0618
ispartof Construction & building materials, 2018-01, Vol.160, p.574-587
issn 0950-0618
1879-0526
language eng
recordid cdi_gale_infotracmisc_A528328246
source Elsevier ScienceDirect Journals Complete
subjects Analysis
Cyclic tests
Glass fibre mesh
Hollow clay bricks
Masonry infills
Mechanical properties
Mortar coating
Reinforced concrete
Retrofitting
title Response of infilled RC frames retrofitted with a cementitious fiber-mesh reinforced coating in moderate seismicity areas
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T14%3A37%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Response%20of%20infilled%20RC%20frames%20retrofitted%20with%20a%20cementitious%20fiber-mesh%20reinforced%20coating%20in%20moderate%20seismicity%20areas&rft.jtitle=Construction%20&%20building%20materials&rft.au=Facconi,%20Luca&rft.date=2018-01-30&rft.volume=160&rft.spage=574&rft.epage=587&rft.pages=574-587&rft.issn=0950-0618&rft.eissn=1879-0526&rft_id=info:doi/10.1016/j.conbuildmat.2017.11.033&rft_dat=%3Cgale_cross%3EA528328246%3C/gale_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A528328246&rft_els_id=S0950061817322456&rfr_iscdi=true