The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures

•A micro-solution electrochemical method is used to evaluate the rebar corrosion.•The corrosion rate of HRB400 in the micro-solution is much lower.•The reason for this difference is the anodic polarization in the micro-solution.•The micro-solution electrochemical method agreed well with the real sit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Construction & building materials 2017-10, Vol.151, p.607-614
Hauptverfasser: Tian, Yuwan, Dong, Chaofang, Cheng, Xuequn, Wan, Yingqi, Wang, Gui, Xiao, Kui, Li, Xiaogang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 614
container_issue
container_start_page 607
container_title Construction & building materials
container_volume 151
creator Tian, Yuwan
Dong, Chaofang
Cheng, Xuequn
Wan, Yingqi
Wang, Gui
Xiao, Kui
Li, Xiaogang
description •A micro-solution electrochemical method is used to evaluate the rebar corrosion.•The corrosion rate of HRB400 in the micro-solution is much lower.•The reason for this difference is the anodic polarization in the micro-solution.•The micro-solution electrochemical method agreed well with the real site studies. An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125μL) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies.
doi_str_mv 10.1016/j.conbuildmat.2017.06.003
format Article
fullrecord <record><control><sourceid>gale_cross</sourceid><recordid>TN_cdi_gale_infotracmisc_A505303324</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A505303324</galeid><els_id>S0950061817311340</els_id><sourcerecordid>A505303324</sourcerecordid><originalsourceid>FETCH-LOGICAL-c463t-f625a5588ddc329cc73841090bde4182dcffe759599998b43461253ea83430f43</originalsourceid><addsrcrecordid>eNqNkcFq3DAQhn1oIGmSd3DotXZHlqW1j2Fpk0Agl-QsZGns1WJLRSMH-vaV2R4S2EMlkGD0_YOYryjuGNQMmPxxrE3ww-pmu-hUN8B2NcgagH8prqAXUIFk3WXxlegIALKRzVUxvR6wXJyJoaIwr8kFX-KMJsVgDpgf9FwumA7BlimU-K7nVScsIw46libEGGiLOJ9Lzo8hGrS57k3EjFGKq0lrRLopLkY9E97-u6-Lt18_X_eP1fPLw9P-_rkyreSpGmUjtBBdZ63hTW_Mjnctgx4Giy3rGmvGEXeiF31e3dDyVrJGcNQdbzmMLb8uvp36TnpGtf0oRW0WR0bdCxAcOG82qjpDTegx6jl4HF0uf-LrM3zedhvR2cD3D4FhJeeR8kFuOiSa9Er0Ge9PePZAFHFUv6NbdPyjGKjNrTqqD27V5laBVNltzu5PWcxjfXcYFRmHPntwMXtUNrj_6PIXRN21Vw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures</title><source>Elsevier ScienceDirect Journals</source><creator>Tian, Yuwan ; Dong, Chaofang ; Cheng, Xuequn ; Wan, Yingqi ; Wang, Gui ; Xiao, Kui ; Li, Xiaogang</creator><creatorcontrib>Tian, Yuwan ; Dong, Chaofang ; Cheng, Xuequn ; Wan, Yingqi ; Wang, Gui ; Xiao, Kui ; Li, Xiaogang</creatorcontrib><description>•A micro-solution electrochemical method is used to evaluate the rebar corrosion.•The corrosion rate of HRB400 in the micro-solution is much lower.•The reason for this difference is the anodic polarization in the micro-solution.•The micro-solution electrochemical method agreed well with the real site studies. An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125μL) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies.</description><identifier>ISSN: 0950-0618</identifier><identifier>DOI: 10.1016/j.conbuildmat.2017.06.003</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Concretes ; Corrosion rate ; Electrochemical technique ; Evaluation ; Methods ; Micro-solution ; Real site ; Rebar corrosion ; Steel corrosion</subject><ispartof>Construction &amp; building materials, 2017-10, Vol.151, p.607-614</ispartof><rights>2017 Elsevier Ltd</rights><rights>COPYRIGHT 2017 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c463t-f625a5588ddc329cc73841090bde4182dcffe759599998b43461253ea83430f43</citedby><cites>FETCH-LOGICAL-c463t-f625a5588ddc329cc73841090bde4182dcffe759599998b43461253ea83430f43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0950061817311340$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Tian, Yuwan</creatorcontrib><creatorcontrib>Dong, Chaofang</creatorcontrib><creatorcontrib>Cheng, Xuequn</creatorcontrib><creatorcontrib>Wan, Yingqi</creatorcontrib><creatorcontrib>Wang, Gui</creatorcontrib><creatorcontrib>Xiao, Kui</creatorcontrib><creatorcontrib>Li, Xiaogang</creatorcontrib><title>The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures</title><title>Construction &amp; building materials</title><description>•A micro-solution electrochemical method is used to evaluate the rebar corrosion.•The corrosion rate of HRB400 in the micro-solution is much lower.•The reason for this difference is the anodic polarization in the micro-solution.•The micro-solution electrochemical method agreed well with the real site studies. An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125μL) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies.</description><subject>Concretes</subject><subject>Corrosion rate</subject><subject>Electrochemical technique</subject><subject>Evaluation</subject><subject>Methods</subject><subject>Micro-solution</subject><subject>Real site</subject><subject>Rebar corrosion</subject><subject>Steel corrosion</subject><issn>0950-0618</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>N95</sourceid><recordid>eNqNkcFq3DAQhn1oIGmSd3DotXZHlqW1j2Fpk0Agl-QsZGns1WJLRSMH-vaV2R4S2EMlkGD0_YOYryjuGNQMmPxxrE3ww-pmu-hUN8B2NcgagH8prqAXUIFk3WXxlegIALKRzVUxvR6wXJyJoaIwr8kFX-KMJsVgDpgf9FwumA7BlimU-K7nVScsIw46libEGGiLOJ9Lzo8hGrS57k3EjFGKq0lrRLopLkY9E97-u6-Lt18_X_eP1fPLw9P-_rkyreSpGmUjtBBdZ63hTW_Mjnctgx4Giy3rGmvGEXeiF31e3dDyVrJGcNQdbzmMLb8uvp36TnpGtf0oRW0WR0bdCxAcOG82qjpDTegx6jl4HF0uf-LrM3zedhvR2cD3D4FhJeeR8kFuOiSa9Er0Ge9PePZAFHFUv6NbdPyjGKjNrTqqD27V5laBVNltzu5PWcxjfXcYFRmHPntwMXtUNrj_6PIXRN21Vw</recordid><startdate>20171001</startdate><enddate>20171001</enddate><creator>Tian, Yuwan</creator><creator>Dong, Chaofang</creator><creator>Cheng, Xuequn</creator><creator>Wan, Yingqi</creator><creator>Wang, Gui</creator><creator>Xiao, Kui</creator><creator>Li, Xiaogang</creator><general>Elsevier Ltd</general><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>N95</scope><scope>XI7</scope></search><sort><creationdate>20171001</creationdate><title>The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures</title><author>Tian, Yuwan ; Dong, Chaofang ; Cheng, Xuequn ; Wan, Yingqi ; Wang, Gui ; Xiao, Kui ; Li, Xiaogang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c463t-f625a5588ddc329cc73841090bde4182dcffe759599998b43461253ea83430f43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Concretes</topic><topic>Corrosion rate</topic><topic>Electrochemical technique</topic><topic>Evaluation</topic><topic>Methods</topic><topic>Micro-solution</topic><topic>Real site</topic><topic>Rebar corrosion</topic><topic>Steel corrosion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tian, Yuwan</creatorcontrib><creatorcontrib>Dong, Chaofang</creatorcontrib><creatorcontrib>Cheng, Xuequn</creatorcontrib><creatorcontrib>Wan, Yingqi</creatorcontrib><creatorcontrib>Wang, Gui</creatorcontrib><creatorcontrib>Xiao, Kui</creatorcontrib><creatorcontrib>Li, Xiaogang</creatorcontrib><collection>CrossRef</collection><collection>Gale Business: Insights</collection><collection>Business Insights: Essentials</collection><jtitle>Construction &amp; building materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tian, Yuwan</au><au>Dong, Chaofang</au><au>Cheng, Xuequn</au><au>Wan, Yingqi</au><au>Wang, Gui</au><au>Xiao, Kui</au><au>Li, Xiaogang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures</atitle><jtitle>Construction &amp; building materials</jtitle><date>2017-10-01</date><risdate>2017</risdate><volume>151</volume><spage>607</spage><epage>614</epage><pages>607-614</pages><issn>0950-0618</issn><abstract>•A micro-solution electrochemical method is used to evaluate the rebar corrosion.•The corrosion rate of HRB400 in the micro-solution is much lower.•The reason for this difference is the anodic polarization in the micro-solution.•The micro-solution electrochemical method agreed well with the real site studies. An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125μL) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.conbuildmat.2017.06.003</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0950-0618
ispartof Construction & building materials, 2017-10, Vol.151, p.607-614
issn 0950-0618
language eng
recordid cdi_gale_infotracmisc_A505303324
source Elsevier ScienceDirect Journals
subjects Concretes
Corrosion rate
Electrochemical technique
Evaluation
Methods
Micro-solution
Real site
Rebar corrosion
Steel corrosion
title The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T14%3A48%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20micro-solution%20electrochemical%20method%20to%20evaluate%20rebar%20corrosion%20in%20reinforced%20concrete%20structures&rft.jtitle=Construction%20&%20building%20materials&rft.au=Tian,%20Yuwan&rft.date=2017-10-01&rft.volume=151&rft.spage=607&rft.epage=614&rft.pages=607-614&rft.issn=0950-0618&rft_id=info:doi/10.1016/j.conbuildmat.2017.06.003&rft_dat=%3Cgale_cross%3EA505303324%3C/gale_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A505303324&rft_els_id=S0950061817311340&rfr_iscdi=true