Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry
A possibility of using inductively-coupled plasma high-resolution mass spectrometry for the isotope analysis of monogermanes enriched with isotopes 72, 73, 74, and 76 has been studied. The effects of isobaric and polyatomic interferences in the spectrum of germanium isotopes have been discussed. It...
Gespeichert in:
Veröffentlicht in: | Journal of analytical chemistry (New York, N.Y.) N.Y.), 2016-07, Vol.71 (7), p.667 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 7 |
container_start_page | 667 |
container_title | Journal of analytical chemistry (New York, N.Y.) |
container_volume | 71 |
creator | Potapov, A.M Kurganova, A.E Bulanov, A.D Troshin, O. Yu Zyryanov, S.M |
description | A possibility of using inductively-coupled plasma high-resolution mass spectrometry for the isotope analysis of monogermanes enriched with isotopes 72, 73, 74, and 76 has been studied. The effects of isobaric and polyatomic interferences in the spectrum of germanium isotopes have been discussed. It has been shown that the signal intensities of [sup.i]Ge[H.sup.+] ions formed in the inductively coupled plasma are 0.00001-0.0001 of the intensity of the [sup.i][Ge.sup.+] signal. This can result in the overestimation of the found concentration of an isotope with a higher mass number next to the main isotope in recording spectra in the low and medium resolution mode. Approaches ensuring the determination of the isotope composition of highly-enriched monogermanes with the range of isotope concentrations extending five orders of magnitude have been proposed. |
doi_str_mv | 10.1134/S1061934816050087 |
format | Article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A496567841</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A496567841</galeid><sourcerecordid>A496567841</sourcerecordid><originalsourceid>FETCH-LOGICAL-g1391-7f087db169cbddb2fb1c802d73456fcb1ec240dec515eacf6add602bfd35b0043</originalsourceid><addsrcrecordid>eNptkM1K5EAUhYM4MP49wOwKXAkmViWVSrIUcbobBMEeVyJN_dyKJUlVyE1k-snm9abEXtjQ3MU9nPOdu7hJ8ovRjLGC36wZFawpeM0ELSmtq6PkJMo6LVjTHEcd4_Qz_5mcIr5TSpuIniT_VhimMACRXnZbdEiCJS84D1mVvy7gZZnhrDL-er0zi0Mm3zelN7tAfA9IH3xoYeylByRqS5w3s57cB3TbVId56MCQoZPYS_Lm2rd0BAzdPLngSS8RCQ6gpzH0MI3b8-SHlR3CxW6fJc-_7__cLdOHx8Xq7vYhbVnRsLSy8RVGMdFoZYzKrWK6prmpCl4KqxUDnXNqQJesBKmtkMYImitrilJRyouz5PLrbis72DhvwzRK3TvUm1veiFJUNWeRSg9QLXgYZRc8WBftPT47wMcx0Dt9sHC1V4jMBH-nVs6Im9X66Tv7H2kWojs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry</title><source>SpringerLink Journals - AutoHoldings</source><creator>Potapov, A.M ; Kurganova, A.E ; Bulanov, A.D ; Troshin, O. Yu ; Zyryanov, S.M</creator><creatorcontrib>Potapov, A.M ; Kurganova, A.E ; Bulanov, A.D ; Troshin, O. Yu ; Zyryanov, S.M</creatorcontrib><description>A possibility of using inductively-coupled plasma high-resolution mass spectrometry for the isotope analysis of monogermanes enriched with isotopes 72, 73, 74, and 76 has been studied. The effects of isobaric and polyatomic interferences in the spectrum of germanium isotopes have been discussed. It has been shown that the signal intensities of [sup.i]Ge[H.sup.+] ions formed in the inductively coupled plasma are 0.00001-0.0001 of the intensity of the [sup.i][Ge.sup.+] signal. This can result in the overestimation of the found concentration of an isotope with a higher mass number next to the main isotope in recording spectra in the low and medium resolution mode. Approaches ensuring the determination of the isotope composition of highly-enriched monogermanes with the range of isotope concentrations extending five orders of magnitude have been proposed.</description><identifier>ISSN: 1061-9348</identifier><identifier>EISSN: 1608-3199</identifier><identifier>DOI: 10.1134/S1061934816050087</identifier><language>eng</language><publisher>Springer</publisher><subject>Chemical properties ; Germanium ; Isotope analysis ; Mass spectrometry ; Methods</subject><ispartof>Journal of analytical chemistry (New York, N.Y.), 2016-07, Vol.71 (7), p.667</ispartof><rights>COPYRIGHT 2016 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27931,27932</link.rule.ids></links><search><creatorcontrib>Potapov, A.M</creatorcontrib><creatorcontrib>Kurganova, A.E</creatorcontrib><creatorcontrib>Bulanov, A.D</creatorcontrib><creatorcontrib>Troshin, O. Yu</creatorcontrib><creatorcontrib>Zyryanov, S.M</creatorcontrib><title>Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry</title><title>Journal of analytical chemistry (New York, N.Y.)</title><description>A possibility of using inductively-coupled plasma high-resolution mass spectrometry for the isotope analysis of monogermanes enriched with isotopes 72, 73, 74, and 76 has been studied. The effects of isobaric and polyatomic interferences in the spectrum of germanium isotopes have been discussed. It has been shown that the signal intensities of [sup.i]Ge[H.sup.+] ions formed in the inductively coupled plasma are 0.00001-0.0001 of the intensity of the [sup.i][Ge.sup.+] signal. This can result in the overestimation of the found concentration of an isotope with a higher mass number next to the main isotope in recording spectra in the low and medium resolution mode. Approaches ensuring the determination of the isotope composition of highly-enriched monogermanes with the range of isotope concentrations extending five orders of magnitude have been proposed.</description><subject>Chemical properties</subject><subject>Germanium</subject><subject>Isotope analysis</subject><subject>Mass spectrometry</subject><subject>Methods</subject><issn>1061-9348</issn><issn>1608-3199</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNptkM1K5EAUhYM4MP49wOwKXAkmViWVSrIUcbobBMEeVyJN_dyKJUlVyE1k-snm9abEXtjQ3MU9nPOdu7hJ8ovRjLGC36wZFawpeM0ELSmtq6PkJMo6LVjTHEcd4_Qz_5mcIr5TSpuIniT_VhimMACRXnZbdEiCJS84D1mVvy7gZZnhrDL-er0zi0Mm3zelN7tAfA9IH3xoYeylByRqS5w3s57cB3TbVId56MCQoZPYS_Lm2rd0BAzdPLngSS8RCQ6gpzH0MI3b8-SHlR3CxW6fJc-_7__cLdOHx8Xq7vYhbVnRsLSy8RVGMdFoZYzKrWK6prmpCl4KqxUDnXNqQJesBKmtkMYImitrilJRyouz5PLrbis72DhvwzRK3TvUm1veiFJUNWeRSg9QLXgYZRc8WBftPT47wMcx0Dt9sHC1V4jMBH-nVs6Im9X66Tv7H2kWojs</recordid><startdate>20160701</startdate><enddate>20160701</enddate><creator>Potapov, A.M</creator><creator>Kurganova, A.E</creator><creator>Bulanov, A.D</creator><creator>Troshin, O. Yu</creator><creator>Zyryanov, S.M</creator><general>Springer</general><scope>ISR</scope></search><sort><creationdate>20160701</creationdate><title>Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry</title><author>Potapov, A.M ; Kurganova, A.E ; Bulanov, A.D ; Troshin, O. Yu ; Zyryanov, S.M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g1391-7f087db169cbddb2fb1c802d73456fcb1ec240dec515eacf6add602bfd35b0043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Chemical properties</topic><topic>Germanium</topic><topic>Isotope analysis</topic><topic>Mass spectrometry</topic><topic>Methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Potapov, A.M</creatorcontrib><creatorcontrib>Kurganova, A.E</creatorcontrib><creatorcontrib>Bulanov, A.D</creatorcontrib><creatorcontrib>Troshin, O. Yu</creatorcontrib><creatorcontrib>Zyryanov, S.M</creatorcontrib><collection>Gale In Context: Science</collection><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Potapov, A.M</au><au>Kurganova, A.E</au><au>Bulanov, A.D</au><au>Troshin, O. Yu</au><au>Zyryanov, S.M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry</atitle><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle><date>2016-07-01</date><risdate>2016</risdate><volume>71</volume><issue>7</issue><spage>667</spage><pages>667-</pages><issn>1061-9348</issn><eissn>1608-3199</eissn><abstract>A possibility of using inductively-coupled plasma high-resolution mass spectrometry for the isotope analysis of monogermanes enriched with isotopes 72, 73, 74, and 76 has been studied. The effects of isobaric and polyatomic interferences in the spectrum of germanium isotopes have been discussed. It has been shown that the signal intensities of [sup.i]Ge[H.sup.+] ions formed in the inductively coupled plasma are 0.00001-0.0001 of the intensity of the [sup.i][Ge.sup.+] signal. This can result in the overestimation of the found concentration of an isotope with a higher mass number next to the main isotope in recording spectra in the low and medium resolution mode. Approaches ensuring the determination of the isotope composition of highly-enriched monogermanes with the range of isotope concentrations extending five orders of magnitude have been proposed.</abstract><pub>Springer</pub><doi>10.1134/S1061934816050087</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1061-9348 |
ispartof | Journal of analytical chemistry (New York, N.Y.), 2016-07, Vol.71 (7), p.667 |
issn | 1061-9348 1608-3199 |
language | eng |
recordid | cdi_gale_infotracmisc_A496567841 |
source | SpringerLink Journals - AutoHoldings |
subjects | Chemical properties Germanium Isotope analysis Mass spectrometry Methods |
title | Isotope analysis of [sup.72]Ge[H.sub.4], [sup.73]Ge[H.sub.4], [sup.74]Ge[H.sub.4], and [sup.76]Ge[H.sub.4] monogermanes by inductively-coupled plasma high-resolution mass spectrometry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T07%3A22%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Isotope%20analysis%20of%20%5Bsup.72%5DGe%5BH.sub.4%5D,%20%5Bsup.73%5DGe%5BH.sub.4%5D,%20%5Bsup.74%5DGe%5BH.sub.4%5D,%20and%20%5Bsup.76%5DGe%5BH.sub.4%5D%20monogermanes%20by%20inductively-coupled%20plasma%20high-resolution%20mass%20spectrometry&rft.jtitle=Journal%20of%20analytical%20chemistry%20(New%20York,%20N.Y.)&rft.au=Potapov,%20A.M&rft.date=2016-07-01&rft.volume=71&rft.issue=7&rft.spage=667&rft.pages=667-&rft.issn=1061-9348&rft.eissn=1608-3199&rft_id=info:doi/10.1134/S1061934816050087&rft_dat=%3Cgale%3EA496567841%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A496567841&rfr_iscdi=true |