Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado

This study aimed to recover the flow rate of clogged drippers with different doses and permanence times of the product MaxBio. The experiment was conducted in a completely randomized design in split-split-plot scheme, where the plots corresponded to product doses (80, 160, 240 and 320 mg [L.sup.-1])...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista brasileira de engenharia agrícola e ambiental 2016-07, Vol.20 (7), p.595
Hauptverfasser: Costa, Danniely O, Batista, Rafael O, Vale, Hudson S.M, de Sousa, Amanda B, Dombroski, Solange A.G, Alves, Sandra M.C
Format: Artikel
Sprache:spa
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 7
container_start_page 595
container_title Revista brasileira de engenharia agrícola e ambiental
container_volume 20
creator Costa, Danniely O
Batista, Rafael O
Vale, Hudson S.M
de Sousa, Amanda B
Dombroski, Solange A.G
Alves, Sandra M.C
description This study aimed to recover the flow rate of clogged drippers with different doses and permanence times of the product MaxBio. The experiment was conducted in a completely randomized design in split-split-plot scheme, where the plots corresponded to product doses (80, 160, 240 and 320 mg [L.sup.-1]), subplots to the applied treatments (T1--without biological treatment, T2--1st application of the product, and T3--2nd application of the product) and in sub-subplots the types of emitters (Plastro Hydrodrip Super, Netafim Tiran and Netafim PCJ-CNJ), with three replicates. The four irrigation units operated with treated domestic wastewater for 400 h in order to clog the emitters. After applying the product MaxBio, the flow rate of the drippers and the relative flow rate reduction were determined to express the unclogging levels. There was significant effect of T2 and T3 on the recovery of the flow rate of the drippers, while for the reduction of relative flow rate, the doses of the product did not show statistical difference regarding the types of drippers. Key words: emitters wastewater unclogging bacteria Objetivou-se, neste trabalho, recuperar a vazao de gotejadores obstruidos com diferentes dosagens e tempos de permanencia do produto MaxBio. O experimento foi montado no delineamento inteiramente casualizado em esquema de parcelas subsubdivididas tendo, nas parcelas, as doses do produto (80, 160, 240 e 320 mg [L.sup.-1]), nas subparcelas, os tratamentos aplicados (T1--sem tratamento biologico; T2--1a aplicacao do produto e T3--2a aplicacao do produto) e, nas subsubparcelas, os tipos de gotejadores (Plastro Hydrodrip Super, Netafim Tiran e Netafim PCJ-CNJ), em tres repeticoes. As quatro unidades de irrigacao operaram com agua residuaria domestica tratada, durante 400 h proporcionando a obstrucao dos gotejadores. Apos aplicacao do produto MaxBio a vazao dos gotejadores e a reducao da vazao relativa foram determinadas para expressar os niveis de desobstrucao. Na recuperacao da vazao dos gotejadores houve efeito significativo dos tratamentos T2 e T3 enquanto para a reducao da vazao relativa as doses do produto nao apresentaram diferenca estatistica em relacao aos tipos de gotejadores. Palavras-chave: emissores agua residuaria desentupimento bacterias
doi_str_mv 10.1590/1807-1929/agriambi.v20n7p595-599
format Article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A461365261</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A461365261</galeid><sourcerecordid>A461365261</sourcerecordid><originalsourceid>FETCH-LOGICAL-g671-755bcbe37987934fe517a71fcc576fc80a5c9bc8bba1237dff249617104f72a23</originalsourceid><addsrcrecordid>eNptjk1LAzEQhnNQsFb_Q8CLl203u5tkc6zFLyh46b3kY7Km7G5Kklr8R_5M01rEgwzMwDvvPO8gdE_KGaGinJO25AURlZjLLjg5KDf7qMqR76igBRXiAk1IQ2jR1IxdoesYt2VJOWFsgr4enO9957TscQog0wBjwt5iE9xuByFindcdGKw-cXoHvI9wXJ-8WTV-gJicxgcZExyyFubrIJM8cjxWZ7rHBnDnE2yl8QEi9iqmsHfGR7yD3mfsyQK23-dD-OX6nJRpxt-gSyv7CLfnOUXrp8f18qVYvT2_LheromOcFJxSpRXUXLRc1I0FSrjkxGpNObO6LSXVQulWKUmqmhtrq0YwwknZWF7Jqp6iux9sJ3vYuNH6nK8HF_Vm0TBSM1rlPkWzf1y5DAz55xGsy_qfg28U2YYs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Costa, Danniely O ; Batista, Rafael O ; Vale, Hudson S.M ; de Sousa, Amanda B ; Dombroski, Solange A.G ; Alves, Sandra M.C</creator><creatorcontrib>Costa, Danniely O ; Batista, Rafael O ; Vale, Hudson S.M ; de Sousa, Amanda B ; Dombroski, Solange A.G ; Alves, Sandra M.C</creatorcontrib><description>This study aimed to recover the flow rate of clogged drippers with different doses and permanence times of the product MaxBio. The experiment was conducted in a completely randomized design in split-split-plot scheme, where the plots corresponded to product doses (80, 160, 240 and 320 mg [L.sup.-1]), subplots to the applied treatments (T1--without biological treatment, T2--1st application of the product, and T3--2nd application of the product) and in sub-subplots the types of emitters (Plastro Hydrodrip Super, Netafim Tiran and Netafim PCJ-CNJ), with three replicates. The four irrigation units operated with treated domestic wastewater for 400 h in order to clog the emitters. After applying the product MaxBio, the flow rate of the drippers and the relative flow rate reduction were determined to express the unclogging levels. There was significant effect of T2 and T3 on the recovery of the flow rate of the drippers, while for the reduction of relative flow rate, the doses of the product did not show statistical difference regarding the types of drippers. Key words: emitters wastewater unclogging bacteria Objetivou-se, neste trabalho, recuperar a vazao de gotejadores obstruidos com diferentes dosagens e tempos de permanencia do produto MaxBio. O experimento foi montado no delineamento inteiramente casualizado em esquema de parcelas subsubdivididas tendo, nas parcelas, as doses do produto (80, 160, 240 e 320 mg [L.sup.-1]), nas subparcelas, os tratamentos aplicados (T1--sem tratamento biologico; T2--1a aplicacao do produto e T3--2a aplicacao do produto) e, nas subsubparcelas, os tipos de gotejadores (Plastro Hydrodrip Super, Netafim Tiran e Netafim PCJ-CNJ), em tres repeticoes. As quatro unidades de irrigacao operaram com agua residuaria domestica tratada, durante 400 h proporcionando a obstrucao dos gotejadores. Apos aplicacao do produto MaxBio a vazao dos gotejadores e a reducao da vazao relativa foram determinadas para expressar os niveis de desobstrucao. Na recuperacao da vazao dos gotejadores houve efeito significativo dos tratamentos T2 e T3 enquanto para a reducao da vazao relativa as doses do produto nao apresentaram diferenca estatistica em relacao aos tipos de gotejadores. Palavras-chave: emissores agua residuaria desentupimento bacterias</description><identifier>ISSN: 1415-4366</identifier><identifier>DOI: 10.1590/1807-1929/agriambi.v20n7p595-599</identifier><language>spa</language><publisher>ATECEL--Associacao Tecnico Cientifica Ernesto Luiz de Oliveira Junior</publisher><ispartof>Revista brasileira de engenharia agrícola e ambiental, 2016-07, Vol.20 (7), p.595</ispartof><rights>COPYRIGHT 2016 ATECEL--Associacao Tecnico Cientifica Ernesto Luiz de Oliveira Junior</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Costa, Danniely O</creatorcontrib><creatorcontrib>Batista, Rafael O</creatorcontrib><creatorcontrib>Vale, Hudson S.M</creatorcontrib><creatorcontrib>de Sousa, Amanda B</creatorcontrib><creatorcontrib>Dombroski, Solange A.G</creatorcontrib><creatorcontrib>Alves, Sandra M.C</creatorcontrib><title>Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado</title><title>Revista brasileira de engenharia agrícola e ambiental</title><description>This study aimed to recover the flow rate of clogged drippers with different doses and permanence times of the product MaxBio. The experiment was conducted in a completely randomized design in split-split-plot scheme, where the plots corresponded to product doses (80, 160, 240 and 320 mg [L.sup.-1]), subplots to the applied treatments (T1--without biological treatment, T2--1st application of the product, and T3--2nd application of the product) and in sub-subplots the types of emitters (Plastro Hydrodrip Super, Netafim Tiran and Netafim PCJ-CNJ), with three replicates. The four irrigation units operated with treated domestic wastewater for 400 h in order to clog the emitters. After applying the product MaxBio, the flow rate of the drippers and the relative flow rate reduction were determined to express the unclogging levels. There was significant effect of T2 and T3 on the recovery of the flow rate of the drippers, while for the reduction of relative flow rate, the doses of the product did not show statistical difference regarding the types of drippers. Key words: emitters wastewater unclogging bacteria Objetivou-se, neste trabalho, recuperar a vazao de gotejadores obstruidos com diferentes dosagens e tempos de permanencia do produto MaxBio. O experimento foi montado no delineamento inteiramente casualizado em esquema de parcelas subsubdivididas tendo, nas parcelas, as doses do produto (80, 160, 240 e 320 mg [L.sup.-1]), nas subparcelas, os tratamentos aplicados (T1--sem tratamento biologico; T2--1a aplicacao do produto e T3--2a aplicacao do produto) e, nas subsubparcelas, os tipos de gotejadores (Plastro Hydrodrip Super, Netafim Tiran e Netafim PCJ-CNJ), em tres repeticoes. As quatro unidades de irrigacao operaram com agua residuaria domestica tratada, durante 400 h proporcionando a obstrucao dos gotejadores. Apos aplicacao do produto MaxBio a vazao dos gotejadores e a reducao da vazao relativa foram determinadas para expressar os niveis de desobstrucao. Na recuperacao da vazao dos gotejadores houve efeito significativo dos tratamentos T2 e T3 enquanto para a reducao da vazao relativa as doses do produto nao apresentaram diferenca estatistica em relacao aos tipos de gotejadores. Palavras-chave: emissores agua residuaria desentupimento bacterias</description><issn>1415-4366</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNptjk1LAzEQhnNQsFb_Q8CLl203u5tkc6zFLyh46b3kY7Km7G5Kklr8R_5M01rEgwzMwDvvPO8gdE_KGaGinJO25AURlZjLLjg5KDf7qMqR76igBRXiAk1IQ2jR1IxdoesYt2VJOWFsgr4enO9957TscQog0wBjwt5iE9xuByFindcdGKw-cXoHvI9wXJ-8WTV-gJicxgcZExyyFubrIJM8cjxWZ7rHBnDnE2yl8QEi9iqmsHfGR7yD3mfsyQK23-dD-OX6nJRpxt-gSyv7CLfnOUXrp8f18qVYvT2_LheromOcFJxSpRXUXLRc1I0FSrjkxGpNObO6LSXVQulWKUmqmhtrq0YwwknZWF7Jqp6iux9sJ3vYuNH6nK8HF_Vm0TBSM1rlPkWzf1y5DAz55xGsy_qfg28U2YYs</recordid><startdate>20160701</startdate><enddate>20160701</enddate><creator>Costa, Danniely O</creator><creator>Batista, Rafael O</creator><creator>Vale, Hudson S.M</creator><creator>de Sousa, Amanda B</creator><creator>Dombroski, Solange A.G</creator><creator>Alves, Sandra M.C</creator><general>ATECEL--Associacao Tecnico Cientifica Ernesto Luiz de Oliveira Junior</general><scope>INF</scope></search><sort><creationdate>20160701</creationdate><title>Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado</title><author>Costa, Danniely O ; Batista, Rafael O ; Vale, Hudson S.M ; de Sousa, Amanda B ; Dombroski, Solange A.G ; Alves, Sandra M.C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g671-755bcbe37987934fe517a71fcc576fc80a5c9bc8bba1237dff249617104f72a23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Costa, Danniely O</creatorcontrib><creatorcontrib>Batista, Rafael O</creatorcontrib><creatorcontrib>Vale, Hudson S.M</creatorcontrib><creatorcontrib>de Sousa, Amanda B</creatorcontrib><creatorcontrib>Dombroski, Solange A.G</creatorcontrib><creatorcontrib>Alves, Sandra M.C</creatorcontrib><collection>Gale OneFile: Informe Academico</collection><jtitle>Revista brasileira de engenharia agrícola e ambiental</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Costa, Danniely O</au><au>Batista, Rafael O</au><au>Vale, Hudson S.M</au><au>de Sousa, Amanda B</au><au>Dombroski, Solange A.G</au><au>Alves, Sandra M.C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado</atitle><jtitle>Revista brasileira de engenharia agrícola e ambiental</jtitle><date>2016-07-01</date><risdate>2016</risdate><volume>20</volume><issue>7</issue><spage>595</spage><pages>595-</pages><issn>1415-4366</issn><abstract>This study aimed to recover the flow rate of clogged drippers with different doses and permanence times of the product MaxBio. The experiment was conducted in a completely randomized design in split-split-plot scheme, where the plots corresponded to product doses (80, 160, 240 and 320 mg [L.sup.-1]), subplots to the applied treatments (T1--without biological treatment, T2--1st application of the product, and T3--2nd application of the product) and in sub-subplots the types of emitters (Plastro Hydrodrip Super, Netafim Tiran and Netafim PCJ-CNJ), with three replicates. The four irrigation units operated with treated domestic wastewater for 400 h in order to clog the emitters. After applying the product MaxBio, the flow rate of the drippers and the relative flow rate reduction were determined to express the unclogging levels. There was significant effect of T2 and T3 on the recovery of the flow rate of the drippers, while for the reduction of relative flow rate, the doses of the product did not show statistical difference regarding the types of drippers. Key words: emitters wastewater unclogging bacteria Objetivou-se, neste trabalho, recuperar a vazao de gotejadores obstruidos com diferentes dosagens e tempos de permanencia do produto MaxBio. O experimento foi montado no delineamento inteiramente casualizado em esquema de parcelas subsubdivididas tendo, nas parcelas, as doses do produto (80, 160, 240 e 320 mg [L.sup.-1]), nas subparcelas, os tratamentos aplicados (T1--sem tratamento biologico; T2--1a aplicacao do produto e T3--2a aplicacao do produto) e, nas subsubparcelas, os tipos de gotejadores (Plastro Hydrodrip Super, Netafim Tiran e Netafim PCJ-CNJ), em tres repeticoes. As quatro unidades de irrigacao operaram com agua residuaria domestica tratada, durante 400 h proporcionando a obstrucao dos gotejadores. Apos aplicacao do produto MaxBio a vazao dos gotejadores e a reducao da vazao relativa foram determinadas para expressar os niveis de desobstrucao. Na recuperacao da vazao dos gotejadores houve efeito significativo dos tratamentos T2 e T3 enquanto para a reducao da vazao relativa as doses do produto nao apresentaram diferenca estatistica em relacao aos tipos de gotejadores. Palavras-chave: emissores agua residuaria desentupimento bacterias</abstract><pub>ATECEL--Associacao Tecnico Cientifica Ernesto Luiz de Oliveira Junior</pub><doi>10.1590/1807-1929/agriambi.v20n7p595-599</doi></addata></record>
fulltext fulltext
identifier ISSN: 1415-4366
ispartof Revista brasileira de engenharia agrícola e ambiental, 2016-07, Vol.20 (7), p.595
issn 1415-4366
language spa
recordid cdi_gale_infotracmisc_A461365261
source EZB-FREE-00999 freely available EZB journals
title Biological treatment of drippers clogged by the use of treated domestic wastewater/Tratamento biologico de gotejadores obstruidos pelo uso de efluente domestico tratado
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T15%3A43%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biological%20treatment%20of%20drippers%20clogged%20by%20the%20use%20of%20treated%20domestic%20wastewater/Tratamento%20biologico%20de%20gotejadores%20obstruidos%20pelo%20uso%20de%20efluente%20domestico%20tratado&rft.jtitle=Revista%20brasileira%20de%20engenharia%20agr%C3%ADcola%20e%20ambiental&rft.au=Costa,%20Danniely%20O&rft.date=2016-07-01&rft.volume=20&rft.issue=7&rft.spage=595&rft.pages=595-&rft.issn=1415-4366&rft_id=info:doi/10.1590/1807-1929/agriambi.v20n7p595-599&rft_dat=%3Cgale%3EA461365261%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A461365261&rfr_iscdi=true