Optimization of the heavy metal
Eight elastomeric composites (NRU, GR1-GR4, NRBG08-NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modif...
Gespeichert in:
Veröffentlicht in: | Journal of radioanalytical and nuclear chemistry 2014-04, Vol.300 (1), p.385 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | 385 |
container_title | Journal of radioanalytical and nuclear chemistry |
container_volume | 300 |
creator | Szajerski, Piotr Zaborski, Marian Bem, Henryk Baryn, Wlodzimierz Kusiak, Edyta |
description | Eight elastomeric composites (NRU, GR1-GR4, NRBG08-NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modified composites. Experimental procedure used for evaluation of the composite shields and their attenuation properties was based on the utilization of HPGe spectrometry and analysis of X-ray fluorescence radiation intensity of the heavy metal additives in the following energy ranges for: Sb (20-35 keV), Gd (35-55 keV), W (55-70 keV) and Bi (70-90 keV). The main contributor to the induced X-ray fluorescence radiation within the shield is Bi additive and the intensity of the X-ray radiation generated within the energy range of 70-90 keV strongly depends on its concentration. It was found that decreasing concentration of the Bi fraction from 0.35 (GR samples) to 0.15 (NRBG samples) results in significant lowering Bi X-ray fluorescence radiation within the 70-90 keV energy range. Secondary effect of decreasing Bi concentration was efficient diminishing excitation processes for lower Z heavy metal additives (W, Gd and Sb, GR vs. NRBG samples). As the final quality parameter of the shielding properties for the examined elastomers, dose reduction factor (DRF) coefficients were calculated for each shield. It was found, that the best shielding properties are observed for composites with lower Bi concentration (0.15 vs. 0.35 Bi mass fraction) with only slight further improvement of their parameters (DRF) with increasing of Gd concentration (Gd mass fraction 0.08, 0.16 and 0.24). The most efficient dose reduction composite was found to be NRBG24 elastomer with DRF value 0.47 (53% dose reduction) for ca. 2 mm and 0.44 g/[cm.sup.2] layer thickness. Keywords X-ray florescence radiation * Dose reduction * Shielding composites * Heavy metal additives * CT * Elastomer shields |
doi_str_mv | 10.1007/s10967-014-2985-5 |
format | Article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A371470562</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A371470562</galeid><sourcerecordid>A371470562</sourcerecordid><originalsourceid>FETCH-LOGICAL-g672-179db0a1ad5192db6b4cc4dfd7c08f1d69517ddf223b04adba5ef4f20b4361183</originalsourceid><addsrcrecordid>eNptjLtKQ0EURadQMEY_wMoL1hPPmfeUIfiCQJr0YZ7JyH2IMwj69V7QwkJ2sWCz9ibkBmGFAPq-IlilKaCgzBpJ5RlZAOOKSs3xglzW-goA1hi-ILe7t1aG8uVamcZuyl07pe6U3MdnN6Tm-itynl1f0_Uvl2T_-LDfPNPt7ulls97So9KMorbRg0MXJVoWvfIiBBFz1AFMxqisRB1jZox7EC56J1MWmYEXXCEaviR3P7dH16dDGfPU3l0YSg2HNdcoNEjFZmv1jzUnpqGEaUy5zP2fwTfwy0z0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimization of the heavy metal</title><source>SpringerNature Journals</source><creator>Szajerski, Piotr ; Zaborski, Marian ; Bem, Henryk ; Baryn, Wlodzimierz ; Kusiak, Edyta</creator><creatorcontrib>Szajerski, Piotr ; Zaborski, Marian ; Bem, Henryk ; Baryn, Wlodzimierz ; Kusiak, Edyta</creatorcontrib><description>Eight elastomeric composites (NRU, GR1-GR4, NRBG08-NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modified composites. Experimental procedure used for evaluation of the composite shields and their attenuation properties was based on the utilization of HPGe spectrometry and analysis of X-ray fluorescence radiation intensity of the heavy metal additives in the following energy ranges for: Sb (20-35 keV), Gd (35-55 keV), W (55-70 keV) and Bi (70-90 keV). The main contributor to the induced X-ray fluorescence radiation within the shield is Bi additive and the intensity of the X-ray radiation generated within the energy range of 70-90 keV strongly depends on its concentration. It was found that decreasing concentration of the Bi fraction from 0.35 (GR samples) to 0.15 (NRBG samples) results in significant lowering Bi X-ray fluorescence radiation within the 70-90 keV energy range. Secondary effect of decreasing Bi concentration was efficient diminishing excitation processes for lower Z heavy metal additives (W, Gd and Sb, GR vs. NRBG samples). As the final quality parameter of the shielding properties for the examined elastomers, dose reduction factor (DRF) coefficients were calculated for each shield. It was found, that the best shielding properties are observed for composites with lower Bi concentration (0.15 vs. 0.35 Bi mass fraction) with only slight further improvement of their parameters (DRF) with increasing of Gd concentration (Gd mass fraction 0.08, 0.16 and 0.24). The most efficient dose reduction composite was found to be NRBG24 elastomer with DRF value 0.47 (53% dose reduction) for ca. 2 mm and 0.44 g/[cm.sup.2] layer thickness. Keywords X-ray florescence radiation * Dose reduction * Shielding composites * Heavy metal additives * CT * Elastomer shields</description><identifier>ISSN: 0236-5731</identifier><identifier>DOI: 10.1007/s10967-014-2985-5</identifier><language>eng</language><publisher>Springer</publisher><subject>Analysis ; CT imaging ; Fluorescence ; Rubber ; X-ray spectroscopy</subject><ispartof>Journal of radioanalytical and nuclear chemistry, 2014-04, Vol.300 (1), p.385</ispartof><rights>COPYRIGHT 2014 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Szajerski, Piotr</creatorcontrib><creatorcontrib>Zaborski, Marian</creatorcontrib><creatorcontrib>Bem, Henryk</creatorcontrib><creatorcontrib>Baryn, Wlodzimierz</creatorcontrib><creatorcontrib>Kusiak, Edyta</creatorcontrib><title>Optimization of the heavy metal</title><title>Journal of radioanalytical and nuclear chemistry</title><description>Eight elastomeric composites (NRU, GR1-GR4, NRBG08-NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modified composites. Experimental procedure used for evaluation of the composite shields and their attenuation properties was based on the utilization of HPGe spectrometry and analysis of X-ray fluorescence radiation intensity of the heavy metal additives in the following energy ranges for: Sb (20-35 keV), Gd (35-55 keV), W (55-70 keV) and Bi (70-90 keV). The main contributor to the induced X-ray fluorescence radiation within the shield is Bi additive and the intensity of the X-ray radiation generated within the energy range of 70-90 keV strongly depends on its concentration. It was found that decreasing concentration of the Bi fraction from 0.35 (GR samples) to 0.15 (NRBG samples) results in significant lowering Bi X-ray fluorescence radiation within the 70-90 keV energy range. Secondary effect of decreasing Bi concentration was efficient diminishing excitation processes for lower Z heavy metal additives (W, Gd and Sb, GR vs. NRBG samples). As the final quality parameter of the shielding properties for the examined elastomers, dose reduction factor (DRF) coefficients were calculated for each shield. It was found, that the best shielding properties are observed for composites with lower Bi concentration (0.15 vs. 0.35 Bi mass fraction) with only slight further improvement of their parameters (DRF) with increasing of Gd concentration (Gd mass fraction 0.08, 0.16 and 0.24). The most efficient dose reduction composite was found to be NRBG24 elastomer with DRF value 0.47 (53% dose reduction) for ca. 2 mm and 0.44 g/[cm.sup.2] layer thickness. Keywords X-ray florescence radiation * Dose reduction * Shielding composites * Heavy metal additives * CT * Elastomer shields</description><subject>Analysis</subject><subject>CT imaging</subject><subject>Fluorescence</subject><subject>Rubber</subject><subject>X-ray spectroscopy</subject><issn>0236-5731</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptjLtKQ0EURadQMEY_wMoL1hPPmfeUIfiCQJr0YZ7JyH2IMwj69V7QwkJ2sWCz9ibkBmGFAPq-IlilKaCgzBpJ5RlZAOOKSs3xglzW-goA1hi-ILe7t1aG8uVamcZuyl07pe6U3MdnN6Tm-itynl1f0_Uvl2T_-LDfPNPt7ulls97So9KMorbRg0MXJVoWvfIiBBFz1AFMxqisRB1jZox7EC56J1MWmYEXXCEaviR3P7dH16dDGfPU3l0YSg2HNdcoNEjFZmv1jzUnpqGEaUy5zP2fwTfwy0z0</recordid><startdate>20140401</startdate><enddate>20140401</enddate><creator>Szajerski, Piotr</creator><creator>Zaborski, Marian</creator><creator>Bem, Henryk</creator><creator>Baryn, Wlodzimierz</creator><creator>Kusiak, Edyta</creator><general>Springer</general><scope/></search><sort><creationdate>20140401</creationdate><title>Optimization of the heavy metal</title><author>Szajerski, Piotr ; Zaborski, Marian ; Bem, Henryk ; Baryn, Wlodzimierz ; Kusiak, Edyta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g672-179db0a1ad5192db6b4cc4dfd7c08f1d69517ddf223b04adba5ef4f20b4361183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Analysis</topic><topic>CT imaging</topic><topic>Fluorescence</topic><topic>Rubber</topic><topic>X-ray spectroscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Szajerski, Piotr</creatorcontrib><creatorcontrib>Zaborski, Marian</creatorcontrib><creatorcontrib>Bem, Henryk</creatorcontrib><creatorcontrib>Baryn, Wlodzimierz</creatorcontrib><creatorcontrib>Kusiak, Edyta</creatorcontrib><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Szajerski, Piotr</au><au>Zaborski, Marian</au><au>Bem, Henryk</au><au>Baryn, Wlodzimierz</au><au>Kusiak, Edyta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of the heavy metal</atitle><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle><date>2014-04-01</date><risdate>2014</risdate><volume>300</volume><issue>1</issue><spage>385</spage><pages>385-</pages><issn>0236-5731</issn><abstract>Eight elastomeric composites (NRU, GR1-GR4, NRBG08-NRBG24) containing mixtures of different proportions of heavy metal additives (Bi, W, Gd and Sb) have been synthesized and examined as protective shields. The NRU sample was a pure rubber matrix and served as a reference sample for heavy metal modified composites. Experimental procedure used for evaluation of the composite shields and their attenuation properties was based on the utilization of HPGe spectrometry and analysis of X-ray fluorescence radiation intensity of the heavy metal additives in the following energy ranges for: Sb (20-35 keV), Gd (35-55 keV), W (55-70 keV) and Bi (70-90 keV). The main contributor to the induced X-ray fluorescence radiation within the shield is Bi additive and the intensity of the X-ray radiation generated within the energy range of 70-90 keV strongly depends on its concentration. It was found that decreasing concentration of the Bi fraction from 0.35 (GR samples) to 0.15 (NRBG samples) results in significant lowering Bi X-ray fluorescence radiation within the 70-90 keV energy range. Secondary effect of decreasing Bi concentration was efficient diminishing excitation processes for lower Z heavy metal additives (W, Gd and Sb, GR vs. NRBG samples). As the final quality parameter of the shielding properties for the examined elastomers, dose reduction factor (DRF) coefficients were calculated for each shield. It was found, that the best shielding properties are observed for composites with lower Bi concentration (0.15 vs. 0.35 Bi mass fraction) with only slight further improvement of their parameters (DRF) with increasing of Gd concentration (Gd mass fraction 0.08, 0.16 and 0.24). The most efficient dose reduction composite was found to be NRBG24 elastomer with DRF value 0.47 (53% dose reduction) for ca. 2 mm and 0.44 g/[cm.sup.2] layer thickness. Keywords X-ray florescence radiation * Dose reduction * Shielding composites * Heavy metal additives * CT * Elastomer shields</abstract><pub>Springer</pub><doi>10.1007/s10967-014-2985-5</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0236-5731 |
ispartof | Journal of radioanalytical and nuclear chemistry, 2014-04, Vol.300 (1), p.385 |
issn | 0236-5731 |
language | eng |
recordid | cdi_gale_infotracmisc_A371470562 |
source | SpringerNature Journals |
subjects | Analysis CT imaging Fluorescence Rubber X-ray spectroscopy |
title | Optimization of the heavy metal |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T22%3A38%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20the%20heavy%20metal&rft.jtitle=Journal%20of%20radioanalytical%20and%20nuclear%20chemistry&rft.au=Szajerski,%20Piotr&rft.date=2014-04-01&rft.volume=300&rft.issue=1&rft.spage=385&rft.pages=385-&rft.issn=0236-5731&rft_id=info:doi/10.1007/s10967-014-2985-5&rft_dat=%3Cgale%3EA371470562%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A371470562&rfr_iscdi=true |