Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer

In laser time-of-flight mass spectrometers, satisfactory resolution by weight is achieved for a fixed initial kinetic energy acquired by the ions in the plasma. The integration of mass spectra in a wide energy range intended for obtaining satisfactory results of analysis leads to a 3–5-fold reductio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical chemistry (New York, N.Y.) N.Y.), 2011-12, Vol.66 (14), p.1455-1463
Hauptverfasser: Bychik, K. G., Voloshko, A. S., Sil’nikov, E. E., Sysoev, Alexey A., Sysoev, Alexandr A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1463
container_issue 14
container_start_page 1455
container_title Journal of analytical chemistry (New York, N.Y.)
container_volume 66
creator Bychik, K. G.
Voloshko, A. S.
Sil’nikov, E. E.
Sysoev, Alexey A.
Sysoev, Alexandr A.
description In laser time-of-flight mass spectrometers, satisfactory resolution by weight is achieved for a fixed initial kinetic energy acquired by the ions in the plasma. The integration of mass spectra in a wide energy range intended for obtaining satisfactory results of analysis leads to a 3–5-fold reduction of the resolving capacity. In the case of the LAMAS-10 device, the resolution for W = 50–300 eV energy dispersion of the ions varies from R ∼ 1000 (for W = 300 eV) to R ∼ 150 (for W = 50 eV), such values being insufficient for quantitative elemental analysis. It has been demonstrated that the main reason for the differences in the resolution values for LAMAS-10 are time aberrations by energies in the laser plasma drift space. The modification of the ion optics theory for LAMAS-10 allows the determination of the principles of the influence of the initial ion energies generated in the laser plasma on the resolution. The dependence of the conditions of the time focusing of ions by energies has been determined in a wide range of the initial values. This dependence provides software-controlled readjustment of the time focusing before the registration of the mass spectra for each initial ion energy. When time focusing of the ions was performed in a wide range of the initial energies, the resolution increased to R = 1300 at W = 50 eV, such parameters providing the quantitative analysis of solid bodies and powders.
doi_str_mv 10.1134/S1061934811140048
format Article
fullrecord <record><control><sourceid>gale_cross</sourceid><recordid>TN_cdi_gale_infotracmisc_A357864171</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A357864171</galeid><sourcerecordid>A357864171</sourcerecordid><originalsourceid>FETCH-LOGICAL-c427t-d7fe4968202e097e86d9f8ca5ca9aa464866f3b8858d56bce8ddbda34d0ccd2b3</originalsourceid><addsrcrecordid>eNp9kd9LwzAQgIMoOKd_gG8Fn3zITNo0TR_L8MdgIjh9Lmly6TraZiQZ6H9vxnwZDrmHO-6-7x7uELqlZEZpxh5WlHBaZkxQShkhTJyhCeVE4IyW5Xms4xjv55foyvsNIaQUlE9QtbBjYrehUz6xJglrSJbVa7XClCS99OCS0A2ArcGm79p1SAbpfeK3oIKzAwRw1-jCyN7DzW-eos-nx4_5C16-PS_m1RIrlhYB68IAK7lISQqkLEBwXRqhZK5kKSXjTHBuskaIXOicNwqE1o2WGdNEKZ022RTdHfa2soe6G40NTqqh86qusrwQnNGCRgqfoFoYwcnejmC62D7iZyf4GBqGTp0U7o-EyAT4Cq3ceV8vVu_HLD2wylnvHZh667pBuu-aknr_tvrP26KTHhwf2bEFV2_szo3xsv9IP2Z8le0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer</title><source>SpringerLink Journals</source><creator>Bychik, K. G. ; Voloshko, A. S. ; Sil’nikov, E. E. ; Sysoev, Alexey A. ; Sysoev, Alexandr A.</creator><creatorcontrib>Bychik, K. G. ; Voloshko, A. S. ; Sil’nikov, E. E. ; Sysoev, Alexey A. ; Sysoev, Alexandr A.</creatorcontrib><description>In laser time-of-flight mass spectrometers, satisfactory resolution by weight is achieved for a fixed initial kinetic energy acquired by the ions in the plasma. The integration of mass spectra in a wide energy range intended for obtaining satisfactory results of analysis leads to a 3–5-fold reduction of the resolving capacity. In the case of the LAMAS-10 device, the resolution for W = 50–300 eV energy dispersion of the ions varies from R ∼ 1000 (for W = 300 eV) to R ∼ 150 (for W = 50 eV), such values being insufficient for quantitative elemental analysis. It has been demonstrated that the main reason for the differences in the resolution values for LAMAS-10 are time aberrations by energies in the laser plasma drift space. The modification of the ion optics theory for LAMAS-10 allows the determination of the principles of the influence of the initial ion energies generated in the laser plasma on the resolution. The dependence of the conditions of the time focusing of ions by energies has been determined in a wide range of the initial values. This dependence provides software-controlled readjustment of the time focusing before the registration of the mass spectra for each initial ion energy. When time focusing of the ions was performed in a wide range of the initial energies, the resolution increased to R = 1300 at W = 50 eV, such parameters providing the quantitative analysis of solid bodies and powders.</description><identifier>ISSN: 1061-9348</identifier><identifier>EISSN: 1608-3199</identifier><identifier>DOI: 10.1134/S1061934811140048</identifier><language>eng</language><publisher>Dordrecht: SP MAIK Nauka/Interperiodica</publisher><subject>Analysis ; Analytical Chemistry ; Chemistry ; Chemistry and Materials Science ; Toy industry</subject><ispartof>Journal of analytical chemistry (New York, N.Y.), 2011-12, Vol.66 (14), p.1455-1463</ispartof><rights>Pleiades Publishing, Ltd. 2011</rights><rights>COPYRIGHT 2011 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c427t-d7fe4968202e097e86d9f8ca5ca9aa464866f3b8858d56bce8ddbda34d0ccd2b3</citedby><cites>FETCH-LOGICAL-c427t-d7fe4968202e097e86d9f8ca5ca9aa464866f3b8858d56bce8ddbda34d0ccd2b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1134/S1061934811140048$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1134/S1061934811140048$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids></links><search><creatorcontrib>Bychik, K. G.</creatorcontrib><creatorcontrib>Voloshko, A. S.</creatorcontrib><creatorcontrib>Sil’nikov, E. E.</creatorcontrib><creatorcontrib>Sysoev, Alexey A.</creatorcontrib><creatorcontrib>Sysoev, Alexandr A.</creatorcontrib><title>Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer</title><title>Journal of analytical chemistry (New York, N.Y.)</title><addtitle>J Anal Chem</addtitle><description>In laser time-of-flight mass spectrometers, satisfactory resolution by weight is achieved for a fixed initial kinetic energy acquired by the ions in the plasma. The integration of mass spectra in a wide energy range intended for obtaining satisfactory results of analysis leads to a 3–5-fold reduction of the resolving capacity. In the case of the LAMAS-10 device, the resolution for W = 50–300 eV energy dispersion of the ions varies from R ∼ 1000 (for W = 300 eV) to R ∼ 150 (for W = 50 eV), such values being insufficient for quantitative elemental analysis. It has been demonstrated that the main reason for the differences in the resolution values for LAMAS-10 are time aberrations by energies in the laser plasma drift space. The modification of the ion optics theory for LAMAS-10 allows the determination of the principles of the influence of the initial ion energies generated in the laser plasma on the resolution. The dependence of the conditions of the time focusing of ions by energies has been determined in a wide range of the initial values. This dependence provides software-controlled readjustment of the time focusing before the registration of the mass spectra for each initial ion energy. When time focusing of the ions was performed in a wide range of the initial energies, the resolution increased to R = 1300 at W = 50 eV, such parameters providing the quantitative analysis of solid bodies and powders.</description><subject>Analysis</subject><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Toy industry</subject><issn>1061-9348</issn><issn>1608-3199</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kd9LwzAQgIMoOKd_gG8Fn3zITNo0TR_L8MdgIjh9Lmly6TraZiQZ6H9vxnwZDrmHO-6-7x7uELqlZEZpxh5WlHBaZkxQShkhTJyhCeVE4IyW5Xms4xjv55foyvsNIaQUlE9QtbBjYrehUz6xJglrSJbVa7XClCS99OCS0A2ArcGm79p1SAbpfeK3oIKzAwRw1-jCyN7DzW-eos-nx4_5C16-PS_m1RIrlhYB68IAK7lISQqkLEBwXRqhZK5kKSXjTHBuskaIXOicNwqE1o2WGdNEKZ022RTdHfa2soe6G40NTqqh86qusrwQnNGCRgqfoFoYwcnejmC62D7iZyf4GBqGTp0U7o-EyAT4Cq3ceV8vVu_HLD2wylnvHZh667pBuu-aknr_tvrP26KTHhwf2bEFV2_szo3xsv9IP2Z8le0</recordid><startdate>20111215</startdate><enddate>20111215</enddate><creator>Bychik, K. G.</creator><creator>Voloshko, A. S.</creator><creator>Sil’nikov, E. E.</creator><creator>Sysoev, Alexey A.</creator><creator>Sysoev, Alexandr A.</creator><general>SP MAIK Nauka/Interperiodica</general><general>Springer</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ISR</scope></search><sort><creationdate>20111215</creationdate><title>Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer</title><author>Bychik, K. G. ; Voloshko, A. S. ; Sil’nikov, E. E. ; Sysoev, Alexey A. ; Sysoev, Alexandr A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c427t-d7fe4968202e097e86d9f8ca5ca9aa464866f3b8858d56bce8ddbda34d0ccd2b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analysis</topic><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Toy industry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bychik, K. G.</creatorcontrib><creatorcontrib>Voloshko, A. S.</creatorcontrib><creatorcontrib>Sil’nikov, E. E.</creatorcontrib><creatorcontrib>Sysoev, Alexey A.</creatorcontrib><creatorcontrib>Sysoev, Alexandr A.</creatorcontrib><collection>CrossRef</collection><collection>Gale In Context: Science</collection><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bychik, K. G.</au><au>Voloshko, A. S.</au><au>Sil’nikov, E. E.</au><au>Sysoev, Alexey A.</au><au>Sysoev, Alexandr A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer</atitle><jtitle>Journal of analytical chemistry (New York, N.Y.)</jtitle><stitle>J Anal Chem</stitle><date>2011-12-15</date><risdate>2011</risdate><volume>66</volume><issue>14</issue><spage>1455</spage><epage>1463</epage><pages>1455-1463</pages><issn>1061-9348</issn><eissn>1608-3199</eissn><abstract>In laser time-of-flight mass spectrometers, satisfactory resolution by weight is achieved for a fixed initial kinetic energy acquired by the ions in the plasma. The integration of mass spectra in a wide energy range intended for obtaining satisfactory results of analysis leads to a 3–5-fold reduction of the resolving capacity. In the case of the LAMAS-10 device, the resolution for W = 50–300 eV energy dispersion of the ions varies from R ∼ 1000 (for W = 300 eV) to R ∼ 150 (for W = 50 eV), such values being insufficient for quantitative elemental analysis. It has been demonstrated that the main reason for the differences in the resolution values for LAMAS-10 are time aberrations by energies in the laser plasma drift space. The modification of the ion optics theory for LAMAS-10 allows the determination of the principles of the influence of the initial ion energies generated in the laser plasma on the resolution. The dependence of the conditions of the time focusing of ions by energies has been determined in a wide range of the initial values. This dependence provides software-controlled readjustment of the time focusing before the registration of the mass spectra for each initial ion energy. When time focusing of the ions was performed in a wide range of the initial energies, the resolution increased to R = 1300 at W = 50 eV, such parameters providing the quantitative analysis of solid bodies and powders.</abstract><cop>Dordrecht</cop><pub>SP MAIK Nauka/Interperiodica</pub><doi>10.1134/S1061934811140048</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1061-9348
ispartof Journal of analytical chemistry (New York, N.Y.), 2011-12, Vol.66 (14), p.1455-1463
issn 1061-9348
1608-3199
language eng
recordid cdi_gale_infotracmisc_A357864171
source SpringerLink Journals
subjects Analysis
Analytical Chemistry
Chemistry
Chemistry and Materials Science
Toy industry
title Ion optics of the LAMAS-10 laser time-of-flight mass spectrometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T21%3A49%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ion%20optics%20of%20the%20LAMAS-10%20laser%20time-of-flight%20mass%20spectrometer&rft.jtitle=Journal%20of%20analytical%20chemistry%20(New%20York,%20N.Y.)&rft.au=Bychik,%20K.%20G.&rft.date=2011-12-15&rft.volume=66&rft.issue=14&rft.spage=1455&rft.epage=1463&rft.pages=1455-1463&rft.issn=1061-9348&rft.eissn=1608-3199&rft_id=info:doi/10.1134/S1061934811140048&rft_dat=%3Cgale_cross%3EA357864171%3C/gale_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A357864171&rfr_iscdi=true