Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus

In order to better detect the early stage of disease nonlinear compliance of artery is considered. Algorithm and MATLAB program analysis M and D mode ultrasound images is created. Program applied for the calculation internal radius of artery and blood flow during the cardiac cycle. Nonlinear Windkes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Elektronika ir elektrotechnika 2010-11 (9(105)), p.93
Hauptverfasser: Kopustinskas, A, Kupciunas, I, Marcinkeviciene, J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 9(105)
container_start_page 93
container_title Elektronika ir elektrotechnika
container_volume
creator Kopustinskas, A
Kupciunas, I
Marcinkeviciene, J
description In order to better detect the early stage of disease nonlinear compliance of artery is considered. Algorithm and MATLAB program analysis M and D mode ultrasound images is created. Program applied for the calculation internal radius of artery and blood flow during the cardiac cycle. Nonlinear Windkessel artery model and by sphygmomanometer calibrated typical blood pressure waveform used for calculation parameters a and b, characterizing exponential dependence compliance with pressure. Experiment "in vivo" with local carotid artery show, that a vary in the range (2,52 ... 3,29) ml/mmHg, b--(0,014 ... 0,021) [mmHg.sup.-1], volume compliance--(0,2 ... 1,2) ml/mmHg. These values match with data, presented in the literature. Direct real time ultrasound measurements of local arterial radius, intima-media thickness and blood velocity allow to increase the plausibility of estimation. Ill. 7, bibl. 6, tabl. 1 (in English; abstracts in English and Lithuanian). Siekiant sudaryti ankstyvujy pokyciu diagnozavimo metodika, nagrinejamas netiesinis arterijos standumas. Sukurti ultragarsiniu M ir D rezimo vaizdu apdorojimo algoritmai ir MATLAB programos arteriju vidiniu sieneliu storiui bei kraujo debitui sirdies pulso metu skaiciuoti. Naudojant netiesini Vindkeselio arterijos modeli ir su sfigmomanometru kalibruota tipine kraujo slegio laiko funkcija gautos parametru a ir b reiksmes, apibudinancios eksponentine standumo priklausomybe nuo slegio. Nustatyta, kad karotidines arterijos parametras a keitesi nuo 2,52 iki 3,29 ml/mmHg, b--nuo 0,014 iki 0,021 mmHg-1, turinis standumas--nuo 0,2 iki 1,2 ml/mmHg. Gauti in vivo iverciai atitinka literaturoje pateikiamus duomenis. Tiesioginiai arterijos lokalinio spindulio ir intima-media storio ir kraujo srauto matavimai igalina padidinti arterijos ivertinimo patikimuma. Il. 7, bibl. 6, lent. 1 (anglu kalba; santraukos anglu ir lietuviu k.).
format Article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracmisc_A249797762</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A249797762</galeid><sourcerecordid>A249797762</sourcerecordid><originalsourceid>FETCH-LOGICAL-g672-1d543c5b5fcc69a6ff233c8fcfb07ae0e9270cf09a685fb1f0e9534df9add70a3</originalsourceid><addsrcrecordid>eNptj71OAzEQhK8AifDzDpaoA75zfM6VURR-pEg06aONvXva6M5GZzsFD8EzYwgFBdpipZlvRrsX1axWXTOvm1pfVdcxHqXURqp2Vn1uYuIREgcvAgmYEk4Mg_DBD-wRJmHD-D4weIsiR_a9yEOaIIbsnSjJHuPj6id1DFF4TIyF4iBiAu_yGASfcEpFGqH4kF04gk_nlh6mbzhHcQL-cDneVpcEQ8S7331T7Z42u_XLfPv2_Lpebed9a8ofTi-U1QdN1rYdtESNUnZJlg7SAErsGiMtyWItNR1qKopWC0cdOGckqJvq_lzbw4B79hTKMXbkaPerZtGZzpi2KdTDP1QZhyPb4JG46H8CX4tfdJc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Kopustinskas, A ; Kupciunas, I ; Marcinkeviciene, J</creator><creatorcontrib>Kopustinskas, A ; Kupciunas, I ; Marcinkeviciene, J</creatorcontrib><description>In order to better detect the early stage of disease nonlinear compliance of artery is considered. Algorithm and MATLAB program analysis M and D mode ultrasound images is created. Program applied for the calculation internal radius of artery and blood flow during the cardiac cycle. Nonlinear Windkessel artery model and by sphygmomanometer calibrated typical blood pressure waveform used for calculation parameters a and b, characterizing exponential dependence compliance with pressure. Experiment "in vivo" with local carotid artery show, that a vary in the range (2,52 ... 3,29) ml/mmHg, b--(0,014 ... 0,021) [mmHg.sup.-1], volume compliance--(0,2 ... 1,2) ml/mmHg. These values match with data, presented in the literature. Direct real time ultrasound measurements of local arterial radius, intima-media thickness and blood velocity allow to increase the plausibility of estimation. Ill. 7, bibl. 6, tabl. 1 (in English; abstracts in English and Lithuanian). Siekiant sudaryti ankstyvujy pokyciu diagnozavimo metodika, nagrinejamas netiesinis arterijos standumas. Sukurti ultragarsiniu M ir D rezimo vaizdu apdorojimo algoritmai ir MATLAB programos arteriju vidiniu sieneliu storiui bei kraujo debitui sirdies pulso metu skaiciuoti. Naudojant netiesini Vindkeselio arterijos modeli ir su sfigmomanometru kalibruota tipine kraujo slegio laiko funkcija gautos parametru a ir b reiksmes, apibudinancios eksponentine standumo priklausomybe nuo slegio. Nustatyta, kad karotidines arterijos parametras a keitesi nuo 2,52 iki 3,29 ml/mmHg, b--nuo 0,014 iki 0,021 mmHg-1, turinis standumas--nuo 0,2 iki 1,2 ml/mmHg. Gauti in vivo iverciai atitinka literaturoje pateikiamus duomenis. Tiesioginiai arterijos lokalinio spindulio ir intima-media storio ir kraujo srauto matavimai igalina padidinti arterijos ivertinimo patikimuma. Il. 7, bibl. 6, lent. 1 (anglu kalba; santraukos anglu ir lietuviu k.).</description><identifier>ISSN: 1392-1215</identifier><language>eng</language><publisher>Kaunas University of Technology, Faculty of Telecommunications and Electronics</publisher><subject>Arteries ; Blood pressure ; Methods ; Physiological aspects ; Ultrasound imaging</subject><ispartof>Elektronika ir elektrotechnika, 2010-11 (9(105)), p.93</ispartof><rights>COPYRIGHT 2010 Kaunas University of Technology, Faculty of Telecommunications and Electronics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Kopustinskas, A</creatorcontrib><creatorcontrib>Kupciunas, I</creatorcontrib><creatorcontrib>Marcinkeviciene, J</creatorcontrib><title>Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus</title><title>Elektronika ir elektrotechnika</title><description>In order to better detect the early stage of disease nonlinear compliance of artery is considered. Algorithm and MATLAB program analysis M and D mode ultrasound images is created. Program applied for the calculation internal radius of artery and blood flow during the cardiac cycle. Nonlinear Windkessel artery model and by sphygmomanometer calibrated typical blood pressure waveform used for calculation parameters a and b, characterizing exponential dependence compliance with pressure. Experiment "in vivo" with local carotid artery show, that a vary in the range (2,52 ... 3,29) ml/mmHg, b--(0,014 ... 0,021) [mmHg.sup.-1], volume compliance--(0,2 ... 1,2) ml/mmHg. These values match with data, presented in the literature. Direct real time ultrasound measurements of local arterial radius, intima-media thickness and blood velocity allow to increase the plausibility of estimation. Ill. 7, bibl. 6, tabl. 1 (in English; abstracts in English and Lithuanian). Siekiant sudaryti ankstyvujy pokyciu diagnozavimo metodika, nagrinejamas netiesinis arterijos standumas. Sukurti ultragarsiniu M ir D rezimo vaizdu apdorojimo algoritmai ir MATLAB programos arteriju vidiniu sieneliu storiui bei kraujo debitui sirdies pulso metu skaiciuoti. Naudojant netiesini Vindkeselio arterijos modeli ir su sfigmomanometru kalibruota tipine kraujo slegio laiko funkcija gautos parametru a ir b reiksmes, apibudinancios eksponentine standumo priklausomybe nuo slegio. Nustatyta, kad karotidines arterijos parametras a keitesi nuo 2,52 iki 3,29 ml/mmHg, b--nuo 0,014 iki 0,021 mmHg-1, turinis standumas--nuo 0,2 iki 1,2 ml/mmHg. Gauti in vivo iverciai atitinka literaturoje pateikiamus duomenis. Tiesioginiai arterijos lokalinio spindulio ir intima-media storio ir kraujo srauto matavimai igalina padidinti arterijos ivertinimo patikimuma. Il. 7, bibl. 6, lent. 1 (anglu kalba; santraukos anglu ir lietuviu k.).</description><subject>Arteries</subject><subject>Blood pressure</subject><subject>Methods</subject><subject>Physiological aspects</subject><subject>Ultrasound imaging</subject><issn>1392-1215</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNptj71OAzEQhK8AifDzDpaoA75zfM6VURR-pEg06aONvXva6M5GZzsFD8EzYwgFBdpipZlvRrsX1axWXTOvm1pfVdcxHqXURqp2Vn1uYuIREgcvAgmYEk4Mg_DBD-wRJmHD-D4weIsiR_a9yEOaIIbsnSjJHuPj6id1DFF4TIyF4iBiAu_yGASfcEpFGqH4kF04gk_nlh6mbzhHcQL-cDneVpcEQ8S7331T7Z42u_XLfPv2_Lpebed9a8ofTi-U1QdN1rYdtESNUnZJlg7SAErsGiMtyWItNR1qKopWC0cdOGckqJvq_lzbw4B79hTKMXbkaPerZtGZzpi2KdTDP1QZhyPb4JG46H8CX4tfdJc</recordid><startdate>20101101</startdate><enddate>20101101</enddate><creator>Kopustinskas, A</creator><creator>Kupciunas, I</creator><creator>Marcinkeviciene, J</creator><general>Kaunas University of Technology, Faculty of Telecommunications and Electronics</general><scope/></search><sort><creationdate>20101101</creationdate><title>Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus</title><author>Kopustinskas, A ; Kupciunas, I ; Marcinkeviciene, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g672-1d543c5b5fcc69a6ff233c8fcfb07ae0e9270cf09a685fb1f0e9534df9add70a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Arteries</topic><topic>Blood pressure</topic><topic>Methods</topic><topic>Physiological aspects</topic><topic>Ultrasound imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kopustinskas, A</creatorcontrib><creatorcontrib>Kupciunas, I</creatorcontrib><creatorcontrib>Marcinkeviciene, J</creatorcontrib><jtitle>Elektronika ir elektrotechnika</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kopustinskas, A</au><au>Kupciunas, I</au><au>Marcinkeviciene, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus</atitle><jtitle>Elektronika ir elektrotechnika</jtitle><date>2010-11-01</date><risdate>2010</risdate><issue>9(105)</issue><spage>93</spage><pages>93-</pages><issn>1392-1215</issn><abstract>In order to better detect the early stage of disease nonlinear compliance of artery is considered. Algorithm and MATLAB program analysis M and D mode ultrasound images is created. Program applied for the calculation internal radius of artery and blood flow during the cardiac cycle. Nonlinear Windkessel artery model and by sphygmomanometer calibrated typical blood pressure waveform used for calculation parameters a and b, characterizing exponential dependence compliance with pressure. Experiment "in vivo" with local carotid artery show, that a vary in the range (2,52 ... 3,29) ml/mmHg, b--(0,014 ... 0,021) [mmHg.sup.-1], volume compliance--(0,2 ... 1,2) ml/mmHg. These values match with data, presented in the literature. Direct real time ultrasound measurements of local arterial radius, intima-media thickness and blood velocity allow to increase the plausibility of estimation. Ill. 7, bibl. 6, tabl. 1 (in English; abstracts in English and Lithuanian). Siekiant sudaryti ankstyvujy pokyciu diagnozavimo metodika, nagrinejamas netiesinis arterijos standumas. Sukurti ultragarsiniu M ir D rezimo vaizdu apdorojimo algoritmai ir MATLAB programos arteriju vidiniu sieneliu storiui bei kraujo debitui sirdies pulso metu skaiciuoti. Naudojant netiesini Vindkeselio arterijos modeli ir su sfigmomanometru kalibruota tipine kraujo slegio laiko funkcija gautos parametru a ir b reiksmes, apibudinancios eksponentine standumo priklausomybe nuo slegio. Nustatyta, kad karotidines arterijos parametras a keitesi nuo 2,52 iki 3,29 ml/mmHg, b--nuo 0,014 iki 0,021 mmHg-1, turinis standumas--nuo 0,2 iki 1,2 ml/mmHg. Gauti in vivo iverciai atitinka literaturoje pateikiamus duomenis. Tiesioginiai arterijos lokalinio spindulio ir intima-media storio ir kraujo srauto matavimai igalina padidinti arterijos ivertinimo patikimuma. Il. 7, bibl. 6, lent. 1 (anglu kalba; santraukos anglu ir lietuviu k.).</abstract><pub>Kaunas University of Technology, Faculty of Telecommunications and Electronics</pub></addata></record>
fulltext fulltext
identifier ISSN: 1392-1215
ispartof Elektronika ir elektrotechnika, 2010-11 (9(105)), p.93
issn 1392-1215
language eng
recordid cdi_gale_infotracmisc_A249797762
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Arteries
Blood pressure
Methods
Physiological aspects
Ultrasound imaging
title Estimation of arterial nonlinear compliance using ultrasound images/Arterijos netiesinio standumo ivertinimas naudojant ultragarsinius vaizdus
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T12%3A40%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimation%20of%20arterial%20nonlinear%20compliance%20using%20ultrasound%20images/Arterijos%20netiesinio%20standumo%20ivertinimas%20naudojant%20ultragarsinius%20vaizdus&rft.jtitle=Elektronika%20ir%20elektrotechnika&rft.au=Kopustinskas,%20A&rft.date=2010-11-01&rft.issue=9(105)&rft.spage=93&rft.pages=93-&rft.issn=1392-1215&rft_id=info:doi/&rft_dat=%3Cgale%3EA249797762%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A249797762&rfr_iscdi=true