Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications
This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of t...
Gespeichert in:
Veröffentlicht in: | Journal of radioanalytical and nuclear chemistry 2014-12, Vol.302 (3), p.1405 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | 1405 |
container_title | Journal of radioanalytical and nuclear chemistry |
container_volume | 302 |
creator | Takale, R.A Sahu, S.K Swarnkar, M Shetty, P.G Pandit, G.G |
description | This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc |
doi_str_mv | 10.1007/s10967-014-3599-7 |
format | Article |
fullrecord | <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracacademiconefile_A391461630</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A391461630</galeid><sourcerecordid>A391461630</sourcerecordid><originalsourceid>FETCH-gale_infotracacademiconefile_A3914616303</originalsourceid><addsrcrecordid>eNqVjM1KAzEURrNQsP48gLv7AhlvzHSmcSet4kLowu5KkczMTbmSn2ESBX16B_QFyll8cOA7QtwqrBRie5cVmqaVqGqpl8bI9kws8F43ctlqdSEuc_5ARLNa6YWg7Vg48I8tnGKG5KCQ8ykChY6GgQZY27f9tsqfXVUfHmDzDZ3Ns969bsClCSh-8ZRioFish5AilzRxPIIdR8_9X_danDvrM93875Wonp926xd5tJ7eObpUJtvPDBS4T5Ecz_5RG1U3qtGoTz78AoSBU1A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><source>SpringerLink Journals</source><creator>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</creator><creatorcontrib>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</creatorcontrib><description>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</description><identifier>ISSN: 0236-5731</identifier><identifier>DOI: 10.1007/s10967-014-3599-7</identifier><language>eng</language><publisher>Springer</publisher><subject>Environmental monitoring ; Gamma rays ; Measurement ; Nuclear energy ; Radiation ; Radiation, Background</subject><ispartof>Journal of radioanalytical and nuclear chemistry, 2014-12, Vol.302 (3), p.1405</ispartof><rights>COPYRIGHT 2014 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Takale, R.A</creatorcontrib><creatorcontrib>Sahu, S.K</creatorcontrib><creatorcontrib>Swarnkar, M</creatorcontrib><creatorcontrib>Shetty, P.G</creatorcontrib><creatorcontrib>Pandit, G.G</creatorcontrib><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><title>Journal of radioanalytical and nuclear chemistry</title><description>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</description><subject>Environmental monitoring</subject><subject>Gamma rays</subject><subject>Measurement</subject><subject>Nuclear energy</subject><subject>Radiation</subject><subject>Radiation, Background</subject><issn>0236-5731</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqVjM1KAzEURrNQsP48gLv7AhlvzHSmcSet4kLowu5KkczMTbmSn2ESBX16B_QFyll8cOA7QtwqrBRie5cVmqaVqGqpl8bI9kws8F43ctlqdSEuc_5ARLNa6YWg7Vg48I8tnGKG5KCQ8ykChY6GgQZY27f9tsqfXVUfHmDzDZ3Ns969bsClCSh-8ZRioFish5AilzRxPIIdR8_9X_danDvrM93875Wonp926xd5tJ7eObpUJtvPDBS4T5Ecz_5RG1U3qtGoTz78AoSBU1A</recordid><startdate>20141201</startdate><enddate>20141201</enddate><creator>Takale, R.A</creator><creator>Sahu, S.K</creator><creator>Swarnkar, M</creator><creator>Shetty, P.G</creator><creator>Pandit, G.G</creator><general>Springer</general><scope/></search><sort><creationdate>20141201</creationdate><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><author>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-gale_infotracacademiconefile_A3914616303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Environmental monitoring</topic><topic>Gamma rays</topic><topic>Measurement</topic><topic>Nuclear energy</topic><topic>Radiation</topic><topic>Radiation, Background</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takale, R.A</creatorcontrib><creatorcontrib>Sahu, S.K</creatorcontrib><creatorcontrib>Swarnkar, M</creatorcontrib><creatorcontrib>Shetty, P.G</creatorcontrib><creatorcontrib>Pandit, G.G</creatorcontrib><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takale, R.A</au><au>Sahu, S.K</au><au>Swarnkar, M</au><au>Shetty, P.G</au><au>Pandit, G.G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</atitle><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle><date>2014-12-01</date><risdate>2014</risdate><volume>302</volume><issue>3</issue><spage>1405</spage><pages>1405-</pages><issn>0236-5731</issn><abstract>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</abstract><pub>Springer</pub><doi>10.1007/s10967-014-3599-7</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0236-5731 |
ispartof | Journal of radioanalytical and nuclear chemistry, 2014-12, Vol.302 (3), p.1405 |
issn | 0236-5731 |
language | eng |
recordid | cdi_gale_infotracacademiconefile_A391461630 |
source | SpringerLink Journals |
subjects | Environmental monitoring Gamma rays Measurement Nuclear energy Radiation Radiation, Background |
title | Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T04%3A22%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimizations%20of%20teflon%20embedded%20CaS%5BO.sub.4%5D:%20Dy%20based%20TLD%20for%20environmental%20monitoring%20applications&rft.jtitle=Journal%20of%20radioanalytical%20and%20nuclear%20chemistry&rft.au=Takale,%20R.A&rft.date=2014-12-01&rft.volume=302&rft.issue=3&rft.spage=1405&rft.pages=1405-&rft.issn=0236-5731&rft_id=info:doi/10.1007/s10967-014-3599-7&rft_dat=%3Cgale%3EA391461630%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A391461630&rfr_iscdi=true |