Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications

This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of radioanalytical and nuclear chemistry 2014-12, Vol.302 (3), p.1405
Hauptverfasser: Takale, R.A, Sahu, S.K, Swarnkar, M, Shetty, P.G, Pandit, G.G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 3
container_start_page 1405
container_title Journal of radioanalytical and nuclear chemistry
container_volume 302
creator Takale, R.A
Sahu, S.K
Swarnkar, M
Shetty, P.G
Pandit, G.G
description This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc
doi_str_mv 10.1007/s10967-014-3599-7
format Article
fullrecord <record><control><sourceid>gale</sourceid><recordid>TN_cdi_gale_infotracacademiconefile_A391461630</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A391461630</galeid><sourcerecordid>A391461630</sourcerecordid><originalsourceid>FETCH-gale_infotracacademiconefile_A3914616303</originalsourceid><addsrcrecordid>eNqVjM1KAzEURrNQsP48gLv7AhlvzHSmcSet4kLowu5KkczMTbmSn2ESBX16B_QFyll8cOA7QtwqrBRie5cVmqaVqGqpl8bI9kws8F43ctlqdSEuc_5ARLNa6YWg7Vg48I8tnGKG5KCQ8ykChY6GgQZY27f9tsqfXVUfHmDzDZ3Ns969bsClCSh-8ZRioFish5AilzRxPIIdR8_9X_danDvrM93875Wonp926xd5tJ7eObpUJtvPDBS4T5Ecz_5RG1U3qtGoTz78AoSBU1A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><source>SpringerLink Journals</source><creator>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</creator><creatorcontrib>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</creatorcontrib><description>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</description><identifier>ISSN: 0236-5731</identifier><identifier>DOI: 10.1007/s10967-014-3599-7</identifier><language>eng</language><publisher>Springer</publisher><subject>Environmental monitoring ; Gamma rays ; Measurement ; Nuclear energy ; Radiation ; Radiation, Background</subject><ispartof>Journal of radioanalytical and nuclear chemistry, 2014-12, Vol.302 (3), p.1405</ispartof><rights>COPYRIGHT 2014 Springer</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Takale, R.A</creatorcontrib><creatorcontrib>Sahu, S.K</creatorcontrib><creatorcontrib>Swarnkar, M</creatorcontrib><creatorcontrib>Shetty, P.G</creatorcontrib><creatorcontrib>Pandit, G.G</creatorcontrib><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><title>Journal of radioanalytical and nuclear chemistry</title><description>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</description><subject>Environmental monitoring</subject><subject>Gamma rays</subject><subject>Measurement</subject><subject>Nuclear energy</subject><subject>Radiation</subject><subject>Radiation, Background</subject><issn>0236-5731</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqVjM1KAzEURrNQsP48gLv7AhlvzHSmcSet4kLowu5KkczMTbmSn2ESBX16B_QFyll8cOA7QtwqrBRie5cVmqaVqGqpl8bI9kws8F43ctlqdSEuc_5ARLNa6YWg7Vg48I8tnGKG5KCQ8ykChY6GgQZY27f9tsqfXVUfHmDzDZ3Ns969bsClCSh-8ZRioFish5AilzRxPIIdR8_9X_danDvrM93875Wonp926xd5tJ7eObpUJtvPDBS4T5Ecz_5RG1U3qtGoTz78AoSBU1A</recordid><startdate>20141201</startdate><enddate>20141201</enddate><creator>Takale, R.A</creator><creator>Sahu, S.K</creator><creator>Swarnkar, M</creator><creator>Shetty, P.G</creator><creator>Pandit, G.G</creator><general>Springer</general><scope/></search><sort><creationdate>20141201</creationdate><title>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</title><author>Takale, R.A ; Sahu, S.K ; Swarnkar, M ; Shetty, P.G ; Pandit, G.G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-gale_infotracacademiconefile_A3914616303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Environmental monitoring</topic><topic>Gamma rays</topic><topic>Measurement</topic><topic>Nuclear energy</topic><topic>Radiation</topic><topic>Radiation, Background</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Takale, R.A</creatorcontrib><creatorcontrib>Sahu, S.K</creatorcontrib><creatorcontrib>Swarnkar, M</creatorcontrib><creatorcontrib>Shetty, P.G</creatorcontrib><creatorcontrib>Pandit, G.G</creatorcontrib><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Takale, R.A</au><au>Sahu, S.K</au><au>Swarnkar, M</au><au>Shetty, P.G</au><au>Pandit, G.G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications</atitle><jtitle>Journal of radioanalytical and nuclear chemistry</jtitle><date>2014-12-01</date><risdate>2014</risdate><volume>302</volume><issue>3</issue><spage>1405</spage><pages>1405-</pages><issn>0236-5731</issn><abstract>This study discusses the optimization of CaS[O.sub.4]: Dy phosphor for its use in environmental monitoring program. In India environmental gamma radiation monitoring, using TLDs is being carried out since last four decades on regular basis. Investigations are made to determine optimum thickness of teflon disc and doping concentration. Teflon disc 0.8 mm thick was found optimum with the 0.2 mol% Dy concentration for highest sensitivity for environmental gamma radiation monitoring. Keywords Environmental TLD * Gamma radiation * Dosimetry * Teflon disc</abstract><pub>Springer</pub><doi>10.1007/s10967-014-3599-7</doi></addata></record>
fulltext fulltext
identifier ISSN: 0236-5731
ispartof Journal of radioanalytical and nuclear chemistry, 2014-12, Vol.302 (3), p.1405
issn 0236-5731
language eng
recordid cdi_gale_infotracacademiconefile_A391461630
source SpringerLink Journals
subjects Environmental monitoring
Gamma rays
Measurement
Nuclear energy
Radiation
Radiation, Background
title Optimizations of teflon embedded CaS[O.sub.4]: Dy based TLD for environmental monitoring applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T04%3A22%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimizations%20of%20teflon%20embedded%20CaS%5BO.sub.4%5D:%20Dy%20based%20TLD%20for%20environmental%20monitoring%20applications&rft.jtitle=Journal%20of%20radioanalytical%20and%20nuclear%20chemistry&rft.au=Takale,%20R.A&rft.date=2014-12-01&rft.volume=302&rft.issue=3&rft.spage=1405&rft.pages=1405-&rft.issn=0236-5731&rft_id=info:doi/10.1007/s10967-014-3599-7&rft_dat=%3Cgale%3EA391461630%3C/gale%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A391461630&rfr_iscdi=true