Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps

The automated transport of cells can enable far-reaching cell culture research. However, to date, such automated transport has been achieved with large pump systems that often come with long fluidic connections and a large power consumption. Improvement is possible with space- and energy-efficient p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bußmann, Agnes, Thalhofer, Thomas, Hoffmann, Sophie, Daum, Leopold, Surendran, Nivedha, Hayden, Oliver, Hubbuch, Jürgen, Richter, Martin
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Bußmann, Agnes
Thalhofer, Thomas
Hoffmann, Sophie
Daum, Leopold
Surendran, Nivedha
Hayden, Oliver
Hubbuch, Jürgen
Richter, Martin
description The automated transport of cells can enable far-reaching cell culture research. However, to date, such automated transport has been achieved with large pump systems that often come with long fluidic connections and a large power consumption. Improvement is possible with space- and energy-efficient piezoelectric micro diaphragm pumps, though a precondition for a successful use is to enable transport with little to no mechanical stress on the cell suspension. This study evaluates the impact of the microfluidic transport of cells with the piezoelectric micro diaphragm pump developed by our group. It includes the investigation of different actuation signals. Therewith, we aim to achieve optimal fluidic performance while maximizing the cell viability. The investigation of fluidic properties proves a similar performance with a hybrid actuation signal that is a rectangular waveform with sinusoidal flanks, compared to the fluidically optimal rectangular actuation. The comparison of the cell transport with three actuation signals, sinusoidal, rectangular, and hybrid actuation shows that the hybrid actuation causes less damage than the rectangular actuation. With a 5% reduction of the cell viability it causes similar strain to the transport with sinusoidal actuation. Piezoelectric micro diaphragm pumps with the fluidically efficient hybrid signal actuation are therefore an interesting option for integrable microfluidic workflows.
doi_str_mv 10.3390/mi12121459
format Article
fullrecord <record><control><sourceid>fraunhofer_E3A</sourceid><recordid>TN_cdi_fraunhofer_primary_oai_fraunhofer_de_N_644495</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_fraunhofer_de_N_644495</sourcerecordid><originalsourceid>FETCH-fraunhofer_primary_oai_fraunhofer_de_N_6444953</originalsourceid><addsrcrecordid>eNqdi7EOgjAURbs4GHXxC_oDKkgxYQaNi4aBvXmBV3hJS5sHxOjXS4yDs7nDSU7OFWIbR_skyaKDo_g4T6XZUhQ3qtkbO1FDtczRWlkx9EPwPMoHjZ0sCV8eLdYjz8UnlwVB6BhaJ8vJhWEtFgbsgJsvV0JdzlV-3RmGqe-8QdaByQE_tQfSP7pBfdcnpVSWJn_e3tmPSLQ</addsrcrecordid><sourcetype>Institutional Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps</title><source>Fraunhofer-ePrints</source><creator>Bußmann, Agnes ; Thalhofer, Thomas ; Hoffmann, Sophie ; Daum, Leopold ; Surendran, Nivedha ; Hayden, Oliver ; Hubbuch, Jürgen ; Richter, Martin</creator><creatorcontrib>Bußmann, Agnes ; Thalhofer, Thomas ; Hoffmann, Sophie ; Daum, Leopold ; Surendran, Nivedha ; Hayden, Oliver ; Hubbuch, Jürgen ; Richter, Martin</creatorcontrib><description>The automated transport of cells can enable far-reaching cell culture research. However, to date, such automated transport has been achieved with large pump systems that often come with long fluidic connections and a large power consumption. Improvement is possible with space- and energy-efficient piezoelectric micro diaphragm pumps, though a precondition for a successful use is to enable transport with little to no mechanical stress on the cell suspension. This study evaluates the impact of the microfluidic transport of cells with the piezoelectric micro diaphragm pump developed by our group. It includes the investigation of different actuation signals. Therewith, we aim to achieve optimal fluidic performance while maximizing the cell viability. The investigation of fluidic properties proves a similar performance with a hybrid actuation signal that is a rectangular waveform with sinusoidal flanks, compared to the fluidically optimal rectangular actuation. The comparison of the cell transport with three actuation signals, sinusoidal, rectangular, and hybrid actuation shows that the hybrid actuation causes less damage than the rectangular actuation. With a 5% reduction of the cell viability it causes similar strain to the transport with sinusoidal actuation. Piezoelectric micro diaphragm pumps with the fluidically efficient hybrid signal actuation are therefore an interesting option for integrable microfluidic workflows.</description><identifier>DOI: 10.3390/mi12121459</identifier><language>eng</language><creationdate>2021</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,780,27860</link.rule.ids><linktorsrc>$$Uhttp://publica.fraunhofer.de/documents/N-644495.html$$EView_record_in_Fraunhofer-Gesellschaft$$FView_record_in_$$GFraunhofer-Gesellschaft$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Bußmann, Agnes</creatorcontrib><creatorcontrib>Thalhofer, Thomas</creatorcontrib><creatorcontrib>Hoffmann, Sophie</creatorcontrib><creatorcontrib>Daum, Leopold</creatorcontrib><creatorcontrib>Surendran, Nivedha</creatorcontrib><creatorcontrib>Hayden, Oliver</creatorcontrib><creatorcontrib>Hubbuch, Jürgen</creatorcontrib><creatorcontrib>Richter, Martin</creatorcontrib><title>Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps</title><description>The automated transport of cells can enable far-reaching cell culture research. However, to date, such automated transport has been achieved with large pump systems that often come with long fluidic connections and a large power consumption. Improvement is possible with space- and energy-efficient piezoelectric micro diaphragm pumps, though a precondition for a successful use is to enable transport with little to no mechanical stress on the cell suspension. This study evaluates the impact of the microfluidic transport of cells with the piezoelectric micro diaphragm pump developed by our group. It includes the investigation of different actuation signals. Therewith, we aim to achieve optimal fluidic performance while maximizing the cell viability. The investigation of fluidic properties proves a similar performance with a hybrid actuation signal that is a rectangular waveform with sinusoidal flanks, compared to the fluidically optimal rectangular actuation. The comparison of the cell transport with three actuation signals, sinusoidal, rectangular, and hybrid actuation shows that the hybrid actuation causes less damage than the rectangular actuation. With a 5% reduction of the cell viability it causes similar strain to the transport with sinusoidal actuation. Piezoelectric micro diaphragm pumps with the fluidically efficient hybrid signal actuation are therefore an interesting option for integrable microfluidic workflows.</description><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>AFSUM</sourceid><sourceid>E3A</sourceid><recordid>eNqdi7EOgjAURbs4GHXxC_oDKkgxYQaNi4aBvXmBV3hJS5sHxOjXS4yDs7nDSU7OFWIbR_skyaKDo_g4T6XZUhQ3qtkbO1FDtczRWlkx9EPwPMoHjZ0sCV8eLdYjz8UnlwVB6BhaJ8vJhWEtFgbsgJsvV0JdzlV-3RmGqe-8QdaByQE_tQfSP7pBfdcnpVSWJn_e3tmPSLQ</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Bußmann, Agnes</creator><creator>Thalhofer, Thomas</creator><creator>Hoffmann, Sophie</creator><creator>Daum, Leopold</creator><creator>Surendran, Nivedha</creator><creator>Hayden, Oliver</creator><creator>Hubbuch, Jürgen</creator><creator>Richter, Martin</creator><scope>AFSUM</scope><scope>E3A</scope></search><sort><creationdate>2021</creationdate><title>Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps</title><author>Bußmann, Agnes ; Thalhofer, Thomas ; Hoffmann, Sophie ; Daum, Leopold ; Surendran, Nivedha ; Hayden, Oliver ; Hubbuch, Jürgen ; Richter, Martin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-fraunhofer_primary_oai_fraunhofer_de_N_6444953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Bußmann, Agnes</creatorcontrib><creatorcontrib>Thalhofer, Thomas</creatorcontrib><creatorcontrib>Hoffmann, Sophie</creatorcontrib><creatorcontrib>Daum, Leopold</creatorcontrib><creatorcontrib>Surendran, Nivedha</creatorcontrib><creatorcontrib>Hayden, Oliver</creatorcontrib><creatorcontrib>Hubbuch, Jürgen</creatorcontrib><creatorcontrib>Richter, Martin</creatorcontrib><collection>Fraunhofer-ePrints - FT</collection><collection>Fraunhofer-ePrints</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Bußmann, Agnes</au><au>Thalhofer, Thomas</au><au>Hoffmann, Sophie</au><au>Daum, Leopold</au><au>Surendran, Nivedha</au><au>Hayden, Oliver</au><au>Hubbuch, Jürgen</au><au>Richter, Martin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps</atitle><date>2021</date><risdate>2021</risdate><abstract>The automated transport of cells can enable far-reaching cell culture research. However, to date, such automated transport has been achieved with large pump systems that often come with long fluidic connections and a large power consumption. Improvement is possible with space- and energy-efficient piezoelectric micro diaphragm pumps, though a precondition for a successful use is to enable transport with little to no mechanical stress on the cell suspension. This study evaluates the impact of the microfluidic transport of cells with the piezoelectric micro diaphragm pump developed by our group. It includes the investigation of different actuation signals. Therewith, we aim to achieve optimal fluidic performance while maximizing the cell viability. The investigation of fluidic properties proves a similar performance with a hybrid actuation signal that is a rectangular waveform with sinusoidal flanks, compared to the fluidically optimal rectangular actuation. The comparison of the cell transport with three actuation signals, sinusoidal, rectangular, and hybrid actuation shows that the hybrid actuation causes less damage than the rectangular actuation. With a 5% reduction of the cell viability it causes similar strain to the transport with sinusoidal actuation. Piezoelectric micro diaphragm pumps with the fluidically efficient hybrid signal actuation are therefore an interesting option for integrable microfluidic workflows.</abstract><doi>10.3390/mi12121459</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.3390/mi12121459
ispartof
issn
language eng
recordid cdi_fraunhofer_primary_oai_fraunhofer_de_N_644495
source Fraunhofer-ePrints
title Microfluidic Cell Transport with Piezoelectric Micro Diaphragm Pumps
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T06%3A25%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-fraunhofer_E3A&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microfluidic%20Cell%20Transport%20with%20Piezoelectric%20Micro%20Diaphragm%20Pumps&rft.au=Bu%C3%9Fmann,%20Agnes&rft.date=2021&rft_id=info:doi/10.3390/mi12121459&rft_dat=%3Cfraunhofer_E3A%3Eoai_fraunhofer_de_N_644495%3C/fraunhofer_E3A%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true