Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy

"We carried out a preliminary experiment for the development of on-line monitoring of raw milk constituents using near-infrared spectroscopy. We took precise measurements of major constituents in raw milk such as fat, protein and lactose in order to investigate effects of wavelength range and l...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nōgyō Kikai Gakkaishi 2002-09, Vol.64 (5)
Hauptverfasser: "Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture), Kawamura, S, Itoh, K.
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 5
container_start_page
container_title Nōgyō Kikai Gakkaishi
container_volume 64
creator "Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture)
Kawamura, S
Itoh, K.
description "We carried out a preliminary experiment for the development of on-line monitoring of raw milk constituents using near-infrared spectroscopy. We took precise measurements of major constituents in raw milk such as fat, protein and lactose in order to investigate effects of wavelength range and light path length on the accuracy of near-infrared measurement. A spectrophotometer (NIRS 6500) was used for near-infrared measurement and MilkoScan S54A was used as a reference constituent analyzer. Light path length (sample cell thickness) was 1, 4 and 10mm and wavelength ranges were set to 400-1,098nm; 600-1,098nm; and 1,100-2,498nm. As a result, the following accuracies were obtained: For fat, SEP=0.17% for the light path-length of 1mm and a wavelength range 1,100-2,498nm, and SEP=0.38% for the path-length of 10mm and a wavelength range 400-1,098nm; for protein, SEP=0.15% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.14% for the path-length of 10mm and a wavelength range 400-1,098nm; and for lactose, SEP=0.10% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.07% for the path-length of 10 mm and a wavelength range 400-1,098nm. It was thus confirmed that accurate measurements could be obtained in the longer wavelength range (1,100-2,498nm) and in the shorter wavelength range (400-1,098nm) when longer path-length was used."
doi_str_mv 10.11357/jsam1937.64.5_83
format Article
fullrecord <record><control><sourceid>fao</sourceid><recordid>TN_cdi_fao_agris_JP2003000851</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>JP2003000851</sourcerecordid><originalsourceid>FETCH-LOGICAL-f139n-2b121d90e20f9a14ebbfe495459008946667775999c67b0b888090a1de4728083</originalsourceid><addsrcrecordid>eNotjktOwzAARL0Aiar0ACyQfIEUf2N7iaryUyVYwLpyHDsxpHZlO6ByDg5MCl2NRk9vNABcYbTEmHJx8571DisqljVb8q2kZ2CGiOQV4YxegEXOvkFESU6wqGfgZ-2cNSXD6OCX_rSDDV3pYdKhs1CHFg6-6wvc69JXJxYDLP0EjRmTNoejeewmhlx8GW0ok6iHQ_Z_q2Po4y52Nvhv28KdHz7gmH3oYLA6VT64pNME8n66kWI2cX-4BOdOD9kuTjkHb3fr19VDtXm-f1zdbiqHqQoVaTDBrUKWIKc0ZrZpnGWKM64QkorVdS2E4EopU4sGNVJKpJDGrWWCSCTpHFz_7zodt7pLPm-fXghCFE0-x_QX71Fm9A</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy</title><source>J-STAGE Free</source><creator>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture) ; Kawamura, S ; Itoh, K.</creator><creatorcontrib>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture) ; Kawamura, S ; Itoh, K.</creatorcontrib><description>"We carried out a preliminary experiment for the development of on-line monitoring of raw milk constituents using near-infrared spectroscopy. We took precise measurements of major constituents in raw milk such as fat, protein and lactose in order to investigate effects of wavelength range and light path length on the accuracy of near-infrared measurement. A spectrophotometer (NIRS 6500) was used for near-infrared measurement and MilkoScan S54A was used as a reference constituent analyzer. Light path length (sample cell thickness) was 1, 4 and 10mm and wavelength ranges were set to 400-1,098nm; 600-1,098nm; and 1,100-2,498nm. As a result, the following accuracies were obtained: For fat, SEP=0.17% for the light path-length of 1mm and a wavelength range 1,100-2,498nm, and SEP=0.38% for the path-length of 10mm and a wavelength range 400-1,098nm; for protein, SEP=0.15% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.14% for the path-length of 10mm and a wavelength range 400-1,098nm; and for lactose, SEP=0.10% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.07% for the path-length of 10 mm and a wavelength range 400-1,098nm. It was thus confirmed that accurate measurements could be obtained in the longer wavelength range (1,100-2,498nm) and in the shorter wavelength range (400-1,098nm) when longer path-length was used."</description><identifier>ISSN: 0285-2543</identifier><identifier>DOI: 10.11357/jsam1937.64.5_83</identifier><language>eng ; jpn</language><subject>CHEMICAL COMPOSITION ; COW MILK ; INFRARED SPECTROPHOTOMETRY ; MEASURING INSTRUMENTS ; OPTICAL PROPERTIES</subject><ispartof>Nōgyō Kikai Gakkaishi, 2002-09, Vol.64 (5)</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture)</creatorcontrib><creatorcontrib>Kawamura, S</creatorcontrib><creatorcontrib>Itoh, K.</creatorcontrib><title>Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy</title><title>Nōgyō Kikai Gakkaishi</title><description>"We carried out a preliminary experiment for the development of on-line monitoring of raw milk constituents using near-infrared spectroscopy. We took precise measurements of major constituents in raw milk such as fat, protein and lactose in order to investigate effects of wavelength range and light path length on the accuracy of near-infrared measurement. A spectrophotometer (NIRS 6500) was used for near-infrared measurement and MilkoScan S54A was used as a reference constituent analyzer. Light path length (sample cell thickness) was 1, 4 and 10mm and wavelength ranges were set to 400-1,098nm; 600-1,098nm; and 1,100-2,498nm. As a result, the following accuracies were obtained: For fat, SEP=0.17% for the light path-length of 1mm and a wavelength range 1,100-2,498nm, and SEP=0.38% for the path-length of 10mm and a wavelength range 400-1,098nm; for protein, SEP=0.15% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.14% for the path-length of 10mm and a wavelength range 400-1,098nm; and for lactose, SEP=0.10% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.07% for the path-length of 10 mm and a wavelength range 400-1,098nm. It was thus confirmed that accurate measurements could be obtained in the longer wavelength range (1,100-2,498nm) and in the shorter wavelength range (400-1,098nm) when longer path-length was used."</description><subject>CHEMICAL COMPOSITION</subject><subject>COW MILK</subject><subject>INFRARED SPECTROPHOTOMETRY</subject><subject>MEASURING INSTRUMENTS</subject><subject>OPTICAL PROPERTIES</subject><issn>0285-2543</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNotjktOwzAARL0Aiar0ACyQfIEUf2N7iaryUyVYwLpyHDsxpHZlO6ByDg5MCl2NRk9vNABcYbTEmHJx8571DisqljVb8q2kZ2CGiOQV4YxegEXOvkFESU6wqGfgZ-2cNSXD6OCX_rSDDV3pYdKhs1CHFg6-6wvc69JXJxYDLP0EjRmTNoejeewmhlx8GW0ok6iHQ_Z_q2Po4y52Nvhv28KdHz7gmH3oYLA6VT64pNME8n66kWI2cX-4BOdOD9kuTjkHb3fr19VDtXm-f1zdbiqHqQoVaTDBrUKWIKc0ZrZpnGWKM64QkorVdS2E4EopU4sGNVJKpJDGrWWCSCTpHFz_7zodt7pLPm-fXghCFE0-x_QX71Fm9A</recordid><startdate>20020901</startdate><enddate>20020901</enddate><creator>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture)</creator><creator>Kawamura, S</creator><creator>Itoh, K.</creator><scope>FBQ</scope></search><sort><creationdate>20020901</creationdate><title>Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy</title><author>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture) ; Kawamura, S ; Itoh, K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-f139n-2b121d90e20f9a14ebbfe495459008946667775999c67b0b888090a1de4728083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; jpn</language><creationdate>2002</creationdate><topic>CHEMICAL COMPOSITION</topic><topic>COW MILK</topic><topic>INFRARED SPECTROPHOTOMETRY</topic><topic>MEASURING INSTRUMENTS</topic><topic>OPTICAL PROPERTIES</topic><toplevel>online_resources</toplevel><creatorcontrib>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture)</creatorcontrib><creatorcontrib>Kawamura, S</creatorcontrib><creatorcontrib>Itoh, K.</creatorcontrib><collection>AGRIS</collection><jtitle>Nōgyō Kikai Gakkaishi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>"Natsuga, M. (Yamagata Univ., Tsuruoka (Japan). Faculty of Agriculture)</au><au>Kawamura, S</au><au>Itoh, K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy</atitle><jtitle>Nōgyō Kikai Gakkaishi</jtitle><date>2002-09-01</date><risdate>2002</risdate><volume>64</volume><issue>5</issue><issn>0285-2543</issn><abstract>"We carried out a preliminary experiment for the development of on-line monitoring of raw milk constituents using near-infrared spectroscopy. We took precise measurements of major constituents in raw milk such as fat, protein and lactose in order to investigate effects of wavelength range and light path length on the accuracy of near-infrared measurement. A spectrophotometer (NIRS 6500) was used for near-infrared measurement and MilkoScan S54A was used as a reference constituent analyzer. Light path length (sample cell thickness) was 1, 4 and 10mm and wavelength ranges were set to 400-1,098nm; 600-1,098nm; and 1,100-2,498nm. As a result, the following accuracies were obtained: For fat, SEP=0.17% for the light path-length of 1mm and a wavelength range 1,100-2,498nm, and SEP=0.38% for the path-length of 10mm and a wavelength range 400-1,098nm; for protein, SEP=0.15% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.14% for the path-length of 10mm and a wavelength range 400-1,098nm; and for lactose, SEP=0.10% for the path-length of 1 mm and a wavelength range 1,100-2,498nm, and SEP=0.07% for the path-length of 10 mm and a wavelength range 400-1,098nm. It was thus confirmed that accurate measurements could be obtained in the longer wavelength range (1,100-2,498nm) and in the shorter wavelength range (400-1,098nm) when longer path-length was used."</abstract><doi>10.11357/jsam1937.64.5_83</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0285-2543
ispartof Nōgyō Kikai Gakkaishi, 2002-09, Vol.64 (5)
issn 0285-2543
language eng ; jpn
recordid cdi_fao_agris_JP2003000851
source J-STAGE Free
subjects CHEMICAL COMPOSITION
COW MILK
INFRARED SPECTROPHOTOMETRY
MEASURING INSTRUMENTS
OPTICAL PROPERTIES
title Effects of wavelength range and light path-length on the accuracy of the constituent analysis of unhomogenized milk using near-infrared spectroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T01%3A38%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-fao&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20wavelength%20range%20and%20light%20path-length%20on%20the%20accuracy%20of%20the%20constituent%20analysis%20of%20unhomogenized%20milk%20using%20near-infrared%20spectroscopy&rft.jtitle=N%C5%8Dgy%C5%8D%20Kikai%20Gakkaishi&rft.au=%22Natsuga,%20M.%20(Yamagata%20Univ.,%20Tsuruoka%20(Japan).%20Faculty%20of%20Agriculture)&rft.date=2002-09-01&rft.volume=64&rft.issue=5&rft.issn=0285-2543&rft_id=info:doi/10.11357/jsam1937.64.5_83&rft_dat=%3Cfao%3EJP2003000851%3C/fao%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true