Measurement of stopping power, residual range and equivalent dose rate of α- particles in polymers PP and PE

The stopping power of α-particles of initial energy 7.69 MeV (emitted from 214Po source) have been measured in the polyethylene(PE) and polypropylene(PP) using surface barrier detector technique and compared with calculated value by SRIM-2003 program. The deviations of the measured data from SRIM�...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:al-Tarbiyah wa-al-ʻilm lil-ʻulūm al-insānīyah : majallah ʻilmīyah muḥakkamah taṣduru ʻan Kullīyat al-Tarbiyah lil-ʻUlūm al-Insānīyah fī Jāmiʻat al-Mawṣil 2009, Vol.22 (2), p.102-113
Hauptverfasser: Mhimid, Ahmad K., Husayn, Ali Kh, Muhammad, Layth R.
Format: Artikel
Sprache:ara ; eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The stopping power of α-particles of initial energy 7.69 MeV (emitted from 214Po source) have been measured in the polyethylene(PE) and polypropylene(PP) using surface barrier detector technique and compared with calculated value by SRIM-2003 program. The deviations of the measured data from SRIM's results in PE and PP films are approximately about 0-7% and 0-11%. An empirical formulae between the stopping power and energy have been found. The residual energy, the residual range and the equivalent dose rate also calculated.
ISSN:1812-125X
2664-2530