Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report

Background The stability of total hip replacements has been directly related to the diameter of the femoral head in several studies; however, durability has necessitated the use of femoral heads with a relatively small diameter. Recent developments in metal-on-metal technology have allowed for the u...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of bone and joint surgery. American volume 2008, Vol.90, p.52-56
1. Verfasser: Stuchin, Steven A., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 56
container_issue
container_start_page 52
container_title Journal of bone and joint surgery. American volume
container_volume 90
creator Stuchin, Steven A., MD
description Background The stability of total hip replacements has been directly related to the diameter of the femoral head in several studies; however, durability has necessitated the use of femoral heads with a relatively small diameter. Recent developments in metal-on-metal technology have allowed for the use of femoral head bearings that are anatomic in diameter. In this case series, we report on the early results of patients who were at greater risk for dislocation because of anatomic deficiencies or increased range-of-motion activities and underwent hip arthroplasty with implants that had articulating surfaces approaching anatomic dimensions. Methods Thirty-four patients underwent forty total hip arthroplasties with use of a modular metal-on-metal articulation with an anatomic diameter femoral head and a press-fit stem. Thirty patients were active, and four patients were profoundly disabled and had bone or soft-tissue deficiencies that would increase the risk for dislocation. Dislocation precautions were maintained for six weeks, and patients were allowed extreme ranges of motion at three months. Results There were no dislocations. Active patients continued in extreme range-of-motion activities. Disabled patients improved but were limited by their comorbidities. Conclusions Anatomic diameter femoral heads offer distinct theoretical advantages in total hip arthroplasty. These short-term results are encouraging, and further study of this new technology in a larger series with a longer follow-up period is warranted. Level of Evidence Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence.
doi_str_mv 10.1016/S0021-9355(08)73131-X
format Article
fullrecord <record><control><sourceid>elsevier</sourceid><recordid>TN_cdi_elsevier_clinicalkeyesjournals_1_s2_0_S002193550873131X</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S002193550873131X</els_id><sourcerecordid>1_s2_0_S002193550873131X</sourcerecordid><originalsourceid>FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S002193550873131X3</originalsourceid><addsrcrecordid>eNqljs1qAkEQhOdgQI0-gtDHeNjY4_qXHIQlUbxFEg_ehmHtkDazM0vPGNi3j0rwBXIqvqIoPqUGGh816tnoA3Gss6d8On3AxXCe61xn-5bq3Oq26sZ4RMTJBOcd9VZ4m0LFJbyyrSiRwJqqINbBhuwhAnvYhXRBrqGQ9CWhdjam5hkK2Ao5rthbaeCd6iCpp-4-rYvU_8t7tVyvdi-bjM7wwySmdOy5tO6bGorHcBJ_3hlt4tiguepfNHFxdd_n_z74BfCnVYU</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report</title><source>Alma/SFX Local Collection</source><creator>Stuchin, Steven A., MD</creator><creatorcontrib>Stuchin, Steven A., MD</creatorcontrib><description>Background The stability of total hip replacements has been directly related to the diameter of the femoral head in several studies; however, durability has necessitated the use of femoral heads with a relatively small diameter. Recent developments in metal-on-metal technology have allowed for the use of femoral head bearings that are anatomic in diameter. In this case series, we report on the early results of patients who were at greater risk for dislocation because of anatomic deficiencies or increased range-of-motion activities and underwent hip arthroplasty with implants that had articulating surfaces approaching anatomic dimensions. Methods Thirty-four patients underwent forty total hip arthroplasties with use of a modular metal-on-metal articulation with an anatomic diameter femoral head and a press-fit stem. Thirty patients were active, and four patients were profoundly disabled and had bone or soft-tissue deficiencies that would increase the risk for dislocation. Dislocation precautions were maintained for six weeks, and patients were allowed extreme ranges of motion at three months. Results There were no dislocations. Active patients continued in extreme range-of-motion activities. Disabled patients improved but were limited by their comorbidities. Conclusions Anatomic diameter femoral heads offer distinct theoretical advantages in total hip arthroplasty. These short-term results are encouraging, and further study of this new technology in a larger series with a longer follow-up period is warranted. Level of Evidence Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence.</description><identifier>ISSN: 0021-9355</identifier><identifier>DOI: 10.1016/S0021-9355(08)73131-X</identifier><language>eng</language><subject>Orthopedics</subject><ispartof>Journal of bone and joint surgery. American volume, 2008, Vol.90, p.52-56</ispartof><rights>The Journal of Bone and Joint Surgery, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Stuchin, Steven A., MD</creatorcontrib><title>Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report</title><title>Journal of bone and joint surgery. American volume</title><description>Background The stability of total hip replacements has been directly related to the diameter of the femoral head in several studies; however, durability has necessitated the use of femoral heads with a relatively small diameter. Recent developments in metal-on-metal technology have allowed for the use of femoral head bearings that are anatomic in diameter. In this case series, we report on the early results of patients who were at greater risk for dislocation because of anatomic deficiencies or increased range-of-motion activities and underwent hip arthroplasty with implants that had articulating surfaces approaching anatomic dimensions. Methods Thirty-four patients underwent forty total hip arthroplasties with use of a modular metal-on-metal articulation with an anatomic diameter femoral head and a press-fit stem. Thirty patients were active, and four patients were profoundly disabled and had bone or soft-tissue deficiencies that would increase the risk for dislocation. Dislocation precautions were maintained for six weeks, and patients were allowed extreme ranges of motion at three months. Results There were no dislocations. Active patients continued in extreme range-of-motion activities. Disabled patients improved but were limited by their comorbidities. Conclusions Anatomic diameter femoral heads offer distinct theoretical advantages in total hip arthroplasty. These short-term results are encouraging, and further study of this new technology in a larger series with a longer follow-up period is warranted. Level of Evidence Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence.</description><subject>Orthopedics</subject><issn>0021-9355</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqljs1qAkEQhOdgQI0-gtDHeNjY4_qXHIQlUbxFEg_ehmHtkDazM0vPGNi3j0rwBXIqvqIoPqUGGh816tnoA3Gss6d8On3AxXCe61xn-5bq3Oq26sZ4RMTJBOcd9VZ4m0LFJbyyrSiRwJqqINbBhuwhAnvYhXRBrqGQ9CWhdjam5hkK2Ao5rthbaeCd6iCpp-4-rYvU_8t7tVyvdi-bjM7wwySmdOy5tO6bGorHcBJ_3hlt4tiguepfNHFxdd_n_z74BfCnVYU</recordid><startdate>2008</startdate><enddate>2008</enddate><creator>Stuchin, Steven A., MD</creator><scope/></search><sort><creationdate>2008</creationdate><title>Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report</title><author>Stuchin, Steven A., MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-elsevier_clinicalkeyesjournals_1_s2_0_S002193550873131X3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stuchin, Steven A., MD</creatorcontrib><jtitle>Journal of bone and joint surgery. American volume</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stuchin, Steven A., MD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report</atitle><jtitle>Journal of bone and joint surgery. American volume</jtitle><date>2008</date><risdate>2008</risdate><volume>90</volume><spage>52</spage><epage>56</epage><pages>52-56</pages><issn>0021-9355</issn><abstract>Background The stability of total hip replacements has been directly related to the diameter of the femoral head in several studies; however, durability has necessitated the use of femoral heads with a relatively small diameter. Recent developments in metal-on-metal technology have allowed for the use of femoral head bearings that are anatomic in diameter. In this case series, we report on the early results of patients who were at greater risk for dislocation because of anatomic deficiencies or increased range-of-motion activities and underwent hip arthroplasty with implants that had articulating surfaces approaching anatomic dimensions. Methods Thirty-four patients underwent forty total hip arthroplasties with use of a modular metal-on-metal articulation with an anatomic diameter femoral head and a press-fit stem. Thirty patients were active, and four patients were profoundly disabled and had bone or soft-tissue deficiencies that would increase the risk for dislocation. Dislocation precautions were maintained for six weeks, and patients were allowed extreme ranges of motion at three months. Results There were no dislocations. Active patients continued in extreme range-of-motion activities. Disabled patients improved but were limited by their comorbidities. Conclusions Anatomic diameter femoral heads offer distinct theoretical advantages in total hip arthroplasty. These short-term results are encouraging, and further study of this new technology in a larger series with a longer follow-up period is warranted. Level of Evidence Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence.</abstract><doi>10.1016/S0021-9355(08)73131-X</doi></addata></record>
fulltext fulltext
identifier ISSN: 0021-9355
ispartof Journal of bone and joint surgery. American volume, 2008, Vol.90, p.52-56
issn 0021-9355
language eng
recordid cdi_elsevier_clinicalkeyesjournals_1_s2_0_S002193550873131X
source Alma/SFX Local Collection
subjects Orthopedics
title Anatomic Diameter Femoral Heads in Total Hip Arthroplasty: A Preliminary Report
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A57%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anatomic%20Diameter%20Femoral%20Heads%20in%20Total%20Hip%20Arthroplasty:%20A%20Preliminary%20Report&rft.jtitle=Journal%20of%20bone%20and%20joint%20surgery.%20American%20volume&rft.au=Stuchin,%20Steven%20A.,%20MD&rft.date=2008&rft.volume=90&rft.spage=52&rft.epage=56&rft.pages=52-56&rft.issn=0021-9355&rft_id=info:doi/10.1016/S0021-9355(08)73131-X&rft_dat=%3Celsevier%3E1_s2_0_S002193550873131X%3C/elsevier%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_els_id=1_s2_0_S002193550873131X&rfr_iscdi=true