Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring

By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons many detection systems, such as the Automated Radioxenon Sampler and Analyzer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Farsoni, Abi T, Hamby, David M
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Farsoni, Abi T
Hamby, David M
description By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and are currently under field tests. These systems employ the beta/gamma coincidence technique to facilitate background rejection. Since all of these systems use two separate detection systems for detecting beta-particles and gamma-rays, the calibration process is usually a tedious task. A phoswich detector, however, can simplify radioxenon detection by measuring both radiations with a single detector. A phoswich detector with Compton suppression capability for measuring xenon radioisotopes has been designed and simulated. The expected performance of the phoswich detector in suppressing Compton interactions and shielding against background radiation was modeled using MCNPX Version 2.5.0. The Compton suppression mechanism is integrated into the phoswich design to effectively reduce the Compton continuum in 2D gamma/beta coincidence spectra and significantly improve the Minimum Detectable Concentration (MDC) of the xenon radioisotopes. The phoswich detector has been designed with three scintillation layers: a thin plastic scintillator layer to detect beta and conversion electrons, a CsI(Tl) crystal layer for detecting X-rays and gamma-rays and a BGO crystal, which surrounds the CsI(Tl) layer, to identify scattered photons and to shield the CsI(Tl) crystal against external gamma-ray background. Published in Proceedings of the 2010 Monitoring Research Review - Ground-Based Nuclear Explosion Monitoring Technologies, 21-23 September 2010, Orlando, FL. Volume II. Sponsored by the Air Force Research Laboratory (AFRL) and the National Nuclear Security Administration (NNSA). U.S. Government or Federal Rights License
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA569562</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA569562</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA5695623</originalsourceid><addsrcrecordid>eNrjZAh3SS3OTM9TSMxLUfDNT0nNycxLV8hPU0hUcM7PLSjJz9MNLi0oKEotLk5NUQjIyC8uz0zOUHBJLUlNLskvUkgD4qDElMz8itS8_DygCXmZQGGgGTwMrGmJOcWpvFCam0HGzTXE2UM3pSQzOb64JDMvtSTe0cXR1MzS1MzImIA0AOftNuw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring</title><source>DTIC Technical Reports</source><creator>Farsoni, Abi T ; Hamby, David M</creator><creatorcontrib>Farsoni, Abi T ; Hamby, David M ; OREGON STATE UNIV CORVALLIS</creatorcontrib><description>By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and are currently under field tests. These systems employ the beta/gamma coincidence technique to facilitate background rejection. Since all of these systems use two separate detection systems for detecting beta-particles and gamma-rays, the calibration process is usually a tedious task. A phoswich detector, however, can simplify radioxenon detection by measuring both radiations with a single detector. A phoswich detector with Compton suppression capability for measuring xenon radioisotopes has been designed and simulated. The expected performance of the phoswich detector in suppressing Compton interactions and shielding against background radiation was modeled using MCNPX Version 2.5.0. The Compton suppression mechanism is integrated into the phoswich design to effectively reduce the Compton continuum in 2D gamma/beta coincidence spectra and significantly improve the Minimum Detectable Concentration (MDC) of the xenon radioisotopes. The phoswich detector has been designed with three scintillation layers: a thin plastic scintillator layer to detect beta and conversion electrons, a CsI(Tl) crystal layer for detecting X-rays and gamma-rays and a BGO crystal, which surrounds the CsI(Tl) layer, to identify scattered photons and to shield the CsI(Tl) crystal against external gamma-ray background. Published in Proceedings of the 2010 Monitoring Research Review - Ground-Based Nuclear Explosion Monitoring Technologies, 21-23 September 2010, Orlando, FL. Volume II. Sponsored by the Air Force Research Laboratory (AFRL) and the National Nuclear Security Administration (NNSA). U.S. Government or Federal Rights License</description><language>eng</language><subject>COINCIDENCE COUNTING ; COMPTON SUPPRESSION ; DETECTORS ; MONITORING ; NUCLEAR EXPLOSION DETECTION ; Nuclear Instrumentation ; PHOSWICH DETECTORS ; RADIOACTIVE ISOTOPES ; RADIOXENON ; XENON</subject><creationdate>2010</creationdate><rights>Approved for public release; distribution is unlimited.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,781,886,27569,27570</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA569562$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Farsoni, Abi T</creatorcontrib><creatorcontrib>Hamby, David M</creatorcontrib><creatorcontrib>OREGON STATE UNIV CORVALLIS</creatorcontrib><title>Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring</title><description>By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and are currently under field tests. These systems employ the beta/gamma coincidence technique to facilitate background rejection. Since all of these systems use two separate detection systems for detecting beta-particles and gamma-rays, the calibration process is usually a tedious task. A phoswich detector, however, can simplify radioxenon detection by measuring both radiations with a single detector. A phoswich detector with Compton suppression capability for measuring xenon radioisotopes has been designed and simulated. The expected performance of the phoswich detector in suppressing Compton interactions and shielding against background radiation was modeled using MCNPX Version 2.5.0. The Compton suppression mechanism is integrated into the phoswich design to effectively reduce the Compton continuum in 2D gamma/beta coincidence spectra and significantly improve the Minimum Detectable Concentration (MDC) of the xenon radioisotopes. The phoswich detector has been designed with three scintillation layers: a thin plastic scintillator layer to detect beta and conversion electrons, a CsI(Tl) crystal layer for detecting X-rays and gamma-rays and a BGO crystal, which surrounds the CsI(Tl) layer, to identify scattered photons and to shield the CsI(Tl) crystal against external gamma-ray background. Published in Proceedings of the 2010 Monitoring Research Review - Ground-Based Nuclear Explosion Monitoring Technologies, 21-23 September 2010, Orlando, FL. Volume II. Sponsored by the Air Force Research Laboratory (AFRL) and the National Nuclear Security Administration (NNSA). U.S. Government or Federal Rights License</description><subject>COINCIDENCE COUNTING</subject><subject>COMPTON SUPPRESSION</subject><subject>DETECTORS</subject><subject>MONITORING</subject><subject>NUCLEAR EXPLOSION DETECTION</subject><subject>Nuclear Instrumentation</subject><subject>PHOSWICH DETECTORS</subject><subject>RADIOACTIVE ISOTOPES</subject><subject>RADIOXENON</subject><subject>XENON</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>2010</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZAh3SS3OTM9TSMxLUfDNT0nNycxLV8hPU0hUcM7PLSjJz9MNLi0oKEotLk5NUQjIyC8uz0zOUHBJLUlNLskvUkgD4qDElMz8itS8_DygCXmZQGGgGTwMrGmJOcWpvFCam0HGzTXE2UM3pSQzOb64JDMvtSTe0cXR1MzS1MzImIA0AOftNuw</recordid><startdate>201009</startdate><enddate>201009</enddate><creator>Farsoni, Abi T</creator><creator>Hamby, David M</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>201009</creationdate><title>Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring</title><author>Farsoni, Abi T ; Hamby, David M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA5695623</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>2010</creationdate><topic>COINCIDENCE COUNTING</topic><topic>COMPTON SUPPRESSION</topic><topic>DETECTORS</topic><topic>MONITORING</topic><topic>NUCLEAR EXPLOSION DETECTION</topic><topic>Nuclear Instrumentation</topic><topic>PHOSWICH DETECTORS</topic><topic>RADIOACTIVE ISOTOPES</topic><topic>RADIOXENON</topic><topic>XENON</topic><toplevel>online_resources</toplevel><creatorcontrib>Farsoni, Abi T</creatorcontrib><creatorcontrib>Hamby, David M</creatorcontrib><creatorcontrib>OREGON STATE UNIV CORVALLIS</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Farsoni, Abi T</au><au>Hamby, David M</au><aucorp>OREGON STATE UNIV CORVALLIS</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring</btitle><date>2010-09</date><risdate>2010</risdate><abstract>By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and are currently under field tests. These systems employ the beta/gamma coincidence technique to facilitate background rejection. Since all of these systems use two separate detection systems for detecting beta-particles and gamma-rays, the calibration process is usually a tedious task. A phoswich detector, however, can simplify radioxenon detection by measuring both radiations with a single detector. A phoswich detector with Compton suppression capability for measuring xenon radioisotopes has been designed and simulated. The expected performance of the phoswich detector in suppressing Compton interactions and shielding against background radiation was modeled using MCNPX Version 2.5.0. The Compton suppression mechanism is integrated into the phoswich design to effectively reduce the Compton continuum in 2D gamma/beta coincidence spectra and significantly improve the Minimum Detectable Concentration (MDC) of the xenon radioisotopes. The phoswich detector has been designed with three scintillation layers: a thin plastic scintillator layer to detect beta and conversion electrons, a CsI(Tl) crystal layer for detecting X-rays and gamma-rays and a BGO crystal, which surrounds the CsI(Tl) layer, to identify scattered photons and to shield the CsI(Tl) crystal against external gamma-ray background. Published in Proceedings of the 2010 Monitoring Research Review - Ground-Based Nuclear Explosion Monitoring Technologies, 21-23 September 2010, Orlando, FL. Volume II. Sponsored by the Air Force Research Laboratory (AFRL) and the National Nuclear Security Administration (NNSA). U.S. Government or Federal Rights License</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA569562
source DTIC Technical Reports
subjects COINCIDENCE COUNTING
COMPTON SUPPRESSION
DETECTORS
MONITORING
NUCLEAR EXPLOSION DETECTION
Nuclear Instrumentation
PHOSWICH DETECTORS
RADIOACTIVE ISOTOPES
RADIOXENON
XENON
title Design and Modeling of a Compton-Suppressed Phoswich Detector for Radioxenon Monitoring
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T17%3A24%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Design%20and%20Modeling%20of%20a%20Compton-Suppressed%20Phoswich%20Detector%20for%20Radioxenon%20Monitoring&rft.au=Farsoni,%20Abi%20T&rft.aucorp=OREGON%20STATE%20UNIV%20CORVALLIS&rft.date=2010-09&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA569562%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true