Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage

Theoretical developments to analyze the impact response of rotated-cut piezoelectric gages are presented. Requirements for an ideal shear gage are outlined, and a theoretical framework to incorporate more realistic response is developed. Impact experiments to determine the current output from 163 de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gupta,Y M, Murri,W J, Aidun,J B
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Gupta,Y M
Murri,W J
Aidun,J B
description Theoretical developments to analyze the impact response of rotated-cut piezoelectric gages are presented. Requirements for an ideal shear gage are outlined, and a theoretical framework to incorporate more realistic response is developed. Impact experiments to determine the current output from 163 deg - and 165.5 deg-rotated Y-cut shorted LiNb03 gages have been performed. The experimental results show that the 163 Y-cut orientation is more sensitive to shear than compression and has no cross-axis shear sensitivity. As expected, the compression response is higher for the 165.5 Y-cut orientation. Experimental results suggest the importance of accounting for the effects of anisotropy, impact tilt, and minor variations in the orientations of the crystals. In detailed comparisons of theory and experiment, these effects were included. These comparisons showed that for shear loading the agreement between theory and experiment is good (within 3 percent); for compression loading the agreement is only to within 10 to 15 percent. An accurate determination of the piezoelectric constant e sub 22 and the elastic constant c sub 12 superscript D, with precise measurements of the orientation of crystals to be used in the experiments, is needed before drawing further conclusions about the causes for the disagreement between theory and experiment. Specific recommendations for future theoretical and experimental efforts are suggested.
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA172414</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA172414</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA1724143</originalsourceid><addsrcrecordid>eNqFjb0KwjAURrM4iPoGDvcFHKoF52Lrzya0m0O5JF9tICYluYr49GZwd_rgnAPfXN26ESFCrGZH7A017wnRPuAlg1aexiKRBKrxggsTMV0tPgEOWqLV1I7gmMOIlOjiBXFgDTrxHUs1G9glrH67UOtj0x3OG5Pv-iTWQ_qqror9tizK3R_9BfbLOBs</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage</title><source>DTIC Technical Reports</source><creator>Gupta,Y M ; Murri,W J ; Aidun,J B</creator><creatorcontrib>Gupta,Y M ; Murri,W J ; Aidun,J B ; SRI INTERNATIONAL MENLO PARK CA</creatorcontrib><description>Theoretical developments to analyze the impact response of rotated-cut piezoelectric gages are presented. Requirements for an ideal shear gage are outlined, and a theoretical framework to incorporate more realistic response is developed. Impact experiments to determine the current output from 163 deg - and 165.5 deg-rotated Y-cut shorted LiNb03 gages have been performed. The experimental results show that the 163 Y-cut orientation is more sensitive to shear than compression and has no cross-axis shear sensitivity. As expected, the compression response is higher for the 165.5 Y-cut orientation. Experimental results suggest the importance of accounting for the effects of anisotropy, impact tilt, and minor variations in the orientations of the crystals. In detailed comparisons of theory and experiment, these effects were included. These comparisons showed that for shear loading the agreement between theory and experiment is good (within 3 percent); for compression loading the agreement is only to within 10 to 15 percent. An accurate determination of the piezoelectric constant e sub 22 and the elastic constant c sub 12 superscript D, with precise measurements of the orientation of crystals to be used in the experiments, is needed before drawing further conclusions about the causes for the disagreement between theory and experiment. Specific recommendations for future theoretical and experimental efforts are suggested.</description><language>eng</language><subject>ANISOTROPY ; AXES ; COMPRESSION ; CONSTANTS ; CRYSTALS ; ELASTIC PROPERTIES ; Electrical and Electronic Equipment ; GAGES ; IMPACT ; IMPACT TESTS ; LITHIUM NIOBATES ; LPN-SRI-PYU-1766 ; LPN-SRI-PYU-4680 ; MEASUREMENT ; ORIENTATION(DIRECTION) ; PE62715H ; PIEZOELECTRIC GAGES ; PIEZOELECTRIC MATERIALS ; PIEZOELECTRIC TRANSDUCERS ; PRECISION ; RESPONSE ; SENSITIVITY ; SHEAR PROPERTIES ; SHEAR STRESSES ; WU14 ; WU34 ; WUDH004745</subject><creationdate>1984</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,27567,27568</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA172414$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Gupta,Y M</creatorcontrib><creatorcontrib>Murri,W J</creatorcontrib><creatorcontrib>Aidun,J B</creatorcontrib><creatorcontrib>SRI INTERNATIONAL MENLO PARK CA</creatorcontrib><title>Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage</title><description>Theoretical developments to analyze the impact response of rotated-cut piezoelectric gages are presented. Requirements for an ideal shear gage are outlined, and a theoretical framework to incorporate more realistic response is developed. Impact experiments to determine the current output from 163 deg - and 165.5 deg-rotated Y-cut shorted LiNb03 gages have been performed. The experimental results show that the 163 Y-cut orientation is more sensitive to shear than compression and has no cross-axis shear sensitivity. As expected, the compression response is higher for the 165.5 Y-cut orientation. Experimental results suggest the importance of accounting for the effects of anisotropy, impact tilt, and minor variations in the orientations of the crystals. In detailed comparisons of theory and experiment, these effects were included. These comparisons showed that for shear loading the agreement between theory and experiment is good (within 3 percent); for compression loading the agreement is only to within 10 to 15 percent. An accurate determination of the piezoelectric constant e sub 22 and the elastic constant c sub 12 superscript D, with precise measurements of the orientation of crystals to be used in the experiments, is needed before drawing further conclusions about the causes for the disagreement between theory and experiment. Specific recommendations for future theoretical and experimental efforts are suggested.</description><subject>ANISOTROPY</subject><subject>AXES</subject><subject>COMPRESSION</subject><subject>CONSTANTS</subject><subject>CRYSTALS</subject><subject>ELASTIC PROPERTIES</subject><subject>Electrical and Electronic Equipment</subject><subject>GAGES</subject><subject>IMPACT</subject><subject>IMPACT TESTS</subject><subject>LITHIUM NIOBATES</subject><subject>LPN-SRI-PYU-1766</subject><subject>LPN-SRI-PYU-4680</subject><subject>MEASUREMENT</subject><subject>ORIENTATION(DIRECTION)</subject><subject>PE62715H</subject><subject>PIEZOELECTRIC GAGES</subject><subject>PIEZOELECTRIC MATERIALS</subject><subject>PIEZOELECTRIC TRANSDUCERS</subject><subject>PRECISION</subject><subject>RESPONSE</subject><subject>SENSITIVITY</subject><subject>SHEAR PROPERTIES</subject><subject>SHEAR STRESSES</subject><subject>WU14</subject><subject>WU34</subject><subject>WUDH004745</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1984</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNqFjb0KwjAURrM4iPoGDvcFHKoF52Lrzya0m0O5JF9tICYluYr49GZwd_rgnAPfXN26ESFCrGZH7A017wnRPuAlg1aexiKRBKrxggsTMV0tPgEOWqLV1I7gmMOIlOjiBXFgDTrxHUs1G9glrH67UOtj0x3OG5Pv-iTWQ_qqror9tizK3R_9BfbLOBs</recordid><startdate>19840831</startdate><enddate>19840831</enddate><creator>Gupta,Y M</creator><creator>Murri,W J</creator><creator>Aidun,J B</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>19840831</creationdate><title>Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage</title><author>Gupta,Y M ; Murri,W J ; Aidun,J B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA1724143</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1984</creationdate><topic>ANISOTROPY</topic><topic>AXES</topic><topic>COMPRESSION</topic><topic>CONSTANTS</topic><topic>CRYSTALS</topic><topic>ELASTIC PROPERTIES</topic><topic>Electrical and Electronic Equipment</topic><topic>GAGES</topic><topic>IMPACT</topic><topic>IMPACT TESTS</topic><topic>LITHIUM NIOBATES</topic><topic>LPN-SRI-PYU-1766</topic><topic>LPN-SRI-PYU-4680</topic><topic>MEASUREMENT</topic><topic>ORIENTATION(DIRECTION)</topic><topic>PE62715H</topic><topic>PIEZOELECTRIC GAGES</topic><topic>PIEZOELECTRIC MATERIALS</topic><topic>PIEZOELECTRIC TRANSDUCERS</topic><topic>PRECISION</topic><topic>RESPONSE</topic><topic>SENSITIVITY</topic><topic>SHEAR PROPERTIES</topic><topic>SHEAR STRESSES</topic><topic>WU14</topic><topic>WU34</topic><topic>WUDH004745</topic><toplevel>online_resources</toplevel><creatorcontrib>Gupta,Y M</creatorcontrib><creatorcontrib>Murri,W J</creatorcontrib><creatorcontrib>Aidun,J B</creatorcontrib><creatorcontrib>SRI INTERNATIONAL MENLO PARK CA</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Gupta,Y M</au><au>Murri,W J</au><au>Aidun,J B</au><aucorp>SRI INTERNATIONAL MENLO PARK CA</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage</btitle><date>1984-08-31</date><risdate>1984</risdate><abstract>Theoretical developments to analyze the impact response of rotated-cut piezoelectric gages are presented. Requirements for an ideal shear gage are outlined, and a theoretical framework to incorporate more realistic response is developed. Impact experiments to determine the current output from 163 deg - and 165.5 deg-rotated Y-cut shorted LiNb03 gages have been performed. The experimental results show that the 163 Y-cut orientation is more sensitive to shear than compression and has no cross-axis shear sensitivity. As expected, the compression response is higher for the 165.5 Y-cut orientation. Experimental results suggest the importance of accounting for the effects of anisotropy, impact tilt, and minor variations in the orientations of the crystals. In detailed comparisons of theory and experiment, these effects were included. These comparisons showed that for shear loading the agreement between theory and experiment is good (within 3 percent); for compression loading the agreement is only to within 10 to 15 percent. An accurate determination of the piezoelectric constant e sub 22 and the elastic constant c sub 12 superscript D, with precise measurements of the orientation of crystals to be used in the experiments, is needed before drawing further conclusions about the causes for the disagreement between theory and experiment. Specific recommendations for future theoretical and experimental efforts are suggested.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA172414
source DTIC Technical Reports
subjects ANISOTROPY
AXES
COMPRESSION
CONSTANTS
CRYSTALS
ELASTIC PROPERTIES
Electrical and Electronic Equipment
GAGES
IMPACT
IMPACT TESTS
LITHIUM NIOBATES
LPN-SRI-PYU-1766
LPN-SRI-PYU-4680
MEASUREMENT
ORIENTATION(DIRECTION)
PE62715H
PIEZOELECTRIC GAGES
PIEZOELECTRIC MATERIALS
PIEZOELECTRIC TRANSDUCERS
PRECISION
RESPONSE
SENSITIVITY
SHEAR PROPERTIES
SHEAR STRESSES
WU14
WU34
WUDH004745
title Theoretical and Experimental Studies to Develop a Piezoelectric Shear Stress Interface Gage
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T13%3A06%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Theoretical%20and%20Experimental%20Studies%20to%20Develop%20a%20Piezoelectric%20Shear%20Stress%20Interface%20Gage&rft.au=Gupta,Y%20M&rft.aucorp=SRI%20INTERNATIONAL%20MENLO%20PARK%20CA&rft.date=1984-08-31&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA172414%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true