Thermal Suppression of Exhaust Pipes

Under the above contract, we were successful in thermally suppressing the hot exhaust gas on a 3 kW engine-generator set. This realistic experiment cooled the engine's exhaust gas from around 400 degrees C down to around 55 degrees C. (Author)

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Allard, Edward F
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Allard, Edward F
description Under the above contract, we were successful in thermally suppressing the hot exhaust gas on a 3 kW engine-generator set. This realistic experiment cooled the engine's exhaust gas from around 400 degrees C down to around 55 degrees C. (Author)
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA119455</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA119455</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA1194553</originalsourceid><addsrcrecordid>eNrjZFAJyUgtyk3MUQguLSgoSi0uzszPU8hPU3CtyEgsLS5RCMgsSC3mYWBNS8wpTuWF0twMMm6uIc4euiklmcnxxSWZeakl8Y4ujoaGliampsYEpAGPISPp</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Thermal Suppression of Exhaust Pipes</title><source>DTIC Technical Reports</source><creator>Allard, Edward F</creator><creatorcontrib>Allard, Edward F ; AREA THERM CORP SPRINGFIELD VA</creatorcontrib><description>Under the above contract, we were successful in thermally suppressing the hot exhaust gas on a 3 kW engine-generator set. This realistic experiment cooled the engine's exhaust gas from around 400 degrees C down to around 55 degrees C. (Author)</description><language>eng</language><subject>AIR EJECTORS ; AIR FLOW ; ASH20 ; COOLING ; Electric Power Production and Distribution ; EXHAUST GASES ; EXHAUST PIPES ; HIGH TEMPERATURE ; MOTOR GENERATORS ; NOZZLES ; PE62733A ; SUPPRESSION</subject><creationdate>1982</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,776,881,27546,27547</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA119455$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Allard, Edward F</creatorcontrib><creatorcontrib>AREA THERM CORP SPRINGFIELD VA</creatorcontrib><title>Thermal Suppression of Exhaust Pipes</title><description>Under the above contract, we were successful in thermally suppressing the hot exhaust gas on a 3 kW engine-generator set. This realistic experiment cooled the engine's exhaust gas from around 400 degrees C down to around 55 degrees C. (Author)</description><subject>AIR EJECTORS</subject><subject>AIR FLOW</subject><subject>ASH20</subject><subject>COOLING</subject><subject>Electric Power Production and Distribution</subject><subject>EXHAUST GASES</subject><subject>EXHAUST PIPES</subject><subject>HIGH TEMPERATURE</subject><subject>MOTOR GENERATORS</subject><subject>NOZZLES</subject><subject>PE62733A</subject><subject>SUPPRESSION</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1982</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZFAJyUgtyk3MUQguLSgoSi0uzszPU8hPU3CtyEgsLS5RCMgsSC3mYWBNS8wpTuWF0twMMm6uIc4euiklmcnxxSWZeakl8Y4ujoaGliampsYEpAGPISPp</recordid><startdate>198209</startdate><enddate>198209</enddate><creator>Allard, Edward F</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>198209</creationdate><title>Thermal Suppression of Exhaust Pipes</title><author>Allard, Edward F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA1194553</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1982</creationdate><topic>AIR EJECTORS</topic><topic>AIR FLOW</topic><topic>ASH20</topic><topic>COOLING</topic><topic>Electric Power Production and Distribution</topic><topic>EXHAUST GASES</topic><topic>EXHAUST PIPES</topic><topic>HIGH TEMPERATURE</topic><topic>MOTOR GENERATORS</topic><topic>NOZZLES</topic><topic>PE62733A</topic><topic>SUPPRESSION</topic><toplevel>online_resources</toplevel><creatorcontrib>Allard, Edward F</creatorcontrib><creatorcontrib>AREA THERM CORP SPRINGFIELD VA</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Allard, Edward F</au><aucorp>AREA THERM CORP SPRINGFIELD VA</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Thermal Suppression of Exhaust Pipes</btitle><date>1982-09</date><risdate>1982</risdate><abstract>Under the above contract, we were successful in thermally suppressing the hot exhaust gas on a 3 kW engine-generator set. This realistic experiment cooled the engine's exhaust gas from around 400 degrees C down to around 55 degrees C. (Author)</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA119455
source DTIC Technical Reports
subjects AIR EJECTORS
AIR FLOW
ASH20
COOLING
Electric Power Production and Distribution
EXHAUST GASES
EXHAUST PIPES
HIGH TEMPERATURE
MOTOR GENERATORS
NOZZLES
PE62733A
SUPPRESSION
title Thermal Suppression of Exhaust Pipes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T03%3A38%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Thermal%20Suppression%20of%20Exhaust%20Pipes&rft.au=Allard,%20Edward%20F&rft.aucorp=AREA%20THERM%20CORP%20SPRINGFIELD%20VA&rft.date=1982-09&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA119455%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true