Solderability Studies Using the Meniscograph

Meniscograph solderability tests were conducted in-house on an extremely large number of specimens (7000) obtained as contract residue. Parameters evaluated were primary and secondary specimen coatings, thickness of coatings, environments that specimens had been exposed to, temperature of the solder...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Cammarere,Mark R
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Cammarere,Mark R
description Meniscograph solderability tests were conducted in-house on an extremely large number of specimens (7000) obtained as contract residue. Parameters evaluated were primary and secondary specimen coatings, thickness of coatings, environments that specimens had been exposed to, temperature of the solder bath, and type of flux. Results quantify the solderability of various coatings, and compare the results of the meniscograph test method with the visual test method. (Author)
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA116115</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA116115</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA1161153</originalsourceid><addsrcrecordid>eNrjZNAJzs9JSS1KTMrMySypVAguKU3JTC1WCC3OzEtXKMlIVfBNzcssTs5PL0osyOBhYE1LzClO5YXS3Awybq4hzh66KSWZyfHFJZl5qSXxji6OhoZmhoamxgSkAQkxJww</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Solderability Studies Using the Meniscograph</title><source>DTIC Technical Reports</source><creator>Cammarere,Mark R</creator><creatorcontrib>Cammarere,Mark R ; ROME AIR DEVELOPMENT CENTER GRIFFISS AFB NY</creatorcontrib><description>Meniscograph solderability tests were conducted in-house on an extremely large number of specimens (7000) obtained as contract residue. Parameters evaluated were primary and secondary specimen coatings, thickness of coatings, environments that specimens had been exposed to, temperature of the solder bath, and type of flux. Results quantify the solderability of various coatings, and compare the results of the meniscograph test method with the visual test method. (Author)</description><language>eng</language><subject>Baths ; Coatings ; Dip coating ; Electrodeposition ; Fabrication Metallurgy ; Flux(Rate) ; Gold ; Meniscograph solderability ; Meniscograph tests ; PE62702F ; Sampling ; Soldering ; Test and evaluation ; Test Facilities, Equipment and Methods ; Test methods ; Test specimens ; Thickness ; Tin ; Visual inspection ; WURADC23380120</subject><creationdate>1982</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,776,881,27544,27545</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA116115$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Cammarere,Mark R</creatorcontrib><creatorcontrib>ROME AIR DEVELOPMENT CENTER GRIFFISS AFB NY</creatorcontrib><title>Solderability Studies Using the Meniscograph</title><description>Meniscograph solderability tests were conducted in-house on an extremely large number of specimens (7000) obtained as contract residue. Parameters evaluated were primary and secondary specimen coatings, thickness of coatings, environments that specimens had been exposed to, temperature of the solder bath, and type of flux. Results quantify the solderability of various coatings, and compare the results of the meniscograph test method with the visual test method. (Author)</description><subject>Baths</subject><subject>Coatings</subject><subject>Dip coating</subject><subject>Electrodeposition</subject><subject>Fabrication Metallurgy</subject><subject>Flux(Rate)</subject><subject>Gold</subject><subject>Meniscograph solderability</subject><subject>Meniscograph tests</subject><subject>PE62702F</subject><subject>Sampling</subject><subject>Soldering</subject><subject>Test and evaluation</subject><subject>Test Facilities, Equipment and Methods</subject><subject>Test methods</subject><subject>Test specimens</subject><subject>Thickness</subject><subject>Tin</subject><subject>Visual inspection</subject><subject>WURADC23380120</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1982</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZNAJzs9JSS1KTMrMySypVAguKU3JTC1WCC3OzEtXKMlIVfBNzcssTs5PL0osyOBhYE1LzClO5YXS3Awybq4hzh66KSWZyfHFJZl5qSXxji6OhoZmhoamxgSkAQkxJww</recordid><startdate>198203</startdate><enddate>198203</enddate><creator>Cammarere,Mark R</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>198203</creationdate><title>Solderability Studies Using the Meniscograph</title><author>Cammarere,Mark R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA1161153</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1982</creationdate><topic>Baths</topic><topic>Coatings</topic><topic>Dip coating</topic><topic>Electrodeposition</topic><topic>Fabrication Metallurgy</topic><topic>Flux(Rate)</topic><topic>Gold</topic><topic>Meniscograph solderability</topic><topic>Meniscograph tests</topic><topic>PE62702F</topic><topic>Sampling</topic><topic>Soldering</topic><topic>Test and evaluation</topic><topic>Test Facilities, Equipment and Methods</topic><topic>Test methods</topic><topic>Test specimens</topic><topic>Thickness</topic><topic>Tin</topic><topic>Visual inspection</topic><topic>WURADC23380120</topic><toplevel>online_resources</toplevel><creatorcontrib>Cammarere,Mark R</creatorcontrib><creatorcontrib>ROME AIR DEVELOPMENT CENTER GRIFFISS AFB NY</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Cammarere,Mark R</au><aucorp>ROME AIR DEVELOPMENT CENTER GRIFFISS AFB NY</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Solderability Studies Using the Meniscograph</btitle><date>1982-03</date><risdate>1982</risdate><abstract>Meniscograph solderability tests were conducted in-house on an extremely large number of specimens (7000) obtained as contract residue. Parameters evaluated were primary and secondary specimen coatings, thickness of coatings, environments that specimens had been exposed to, temperature of the solder bath, and type of flux. Results quantify the solderability of various coatings, and compare the results of the meniscograph test method with the visual test method. (Author)</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA116115
source DTIC Technical Reports
subjects Baths
Coatings
Dip coating
Electrodeposition
Fabrication Metallurgy
Flux(Rate)
Gold
Meniscograph solderability
Meniscograph tests
PE62702F
Sampling
Soldering
Test and evaluation
Test Facilities, Equipment and Methods
Test methods
Test specimens
Thickness
Tin
Visual inspection
WURADC23380120
title Solderability Studies Using the Meniscograph
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T02%3A29%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Solderability%20Studies%20Using%20the%20Meniscograph&rft.au=Cammarere,Mark%20R&rft.aucorp=ROME%20AIR%20DEVELOPMENT%20CENTER%20GRIFFISS%20AFB%20NY&rft.date=1982-03&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA116115%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true