Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM

The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and en...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Horn, Dennis D, Smith, Richard T
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Horn, Dennis D
Smith, Richard T
description The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented. See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA017288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA017288</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA0172883</originalsourceid><addsrcrecordid>eNrjZAgISi0uzSkpVshPUwhJLS7JzEtXKMlIVXB0dXFWMNX1DVcITk3PTc0rSU1RcAxyVvBITSxJLVJILFEIKEotLi4FEgqlBQol-QqG5oYKjiG-PAysaYk5xam8UJqbQcbNNcTZQzelJDM5HmRBakm8o4ujgaG5kYWFMQFpAN-wMM8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><source>DTIC Technical Reports</source><creator>Horn, Dennis D ; Smith, Richard T</creator><creatorcontrib>Horn, Dennis D ; Smith, Richard T ; ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><description>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented. See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</description><language>eng</language><subject>Air Condition, Heating, Lighting &amp; Ventilating ; ARC HEATERS ; COMPARISON ; DIRECT CURRENT ; ENTHALPY ; HIGH PRESSURE ; MEASUREMENT ; NOZZLE GAS FLOW ; TEST EQUIPMENT ; Test Facilities, Equipment and Methods ; TEST METHODS ; WIND TUNNEL TESTS</subject><creationdate>1975</creationdate><rights>Approved for public release; distribution is unlimited.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,27567,27568</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA017288$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Horn, Dennis D</creatorcontrib><creatorcontrib>Smith, Richard T</creatorcontrib><creatorcontrib>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><description>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented. See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</description><subject>Air Condition, Heating, Lighting &amp; Ventilating</subject><subject>ARC HEATERS</subject><subject>COMPARISON</subject><subject>DIRECT CURRENT</subject><subject>ENTHALPY</subject><subject>HIGH PRESSURE</subject><subject>MEASUREMENT</subject><subject>NOZZLE GAS FLOW</subject><subject>TEST EQUIPMENT</subject><subject>Test Facilities, Equipment and Methods</subject><subject>TEST METHODS</subject><subject>WIND TUNNEL TESTS</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1975</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZAgISi0uzSkpVshPUwhJLS7JzEtXKMlIVXB0dXFWMNX1DVcITk3PTc0rSU1RcAxyVvBITSxJLVJILFEIKEotLi4FEgqlBQol-QqG5oYKjiG-PAysaYk5xam8UJqbQcbNNcTZQzelJDM5HmRBakm8o4ujgaG5kYWFMQFpAN-wMM8</recordid><startdate>197511</startdate><enddate>197511</enddate><creator>Horn, Dennis D</creator><creator>Smith, Richard T</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>197511</creationdate><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><author>Horn, Dennis D ; Smith, Richard T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA0172883</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1975</creationdate><topic>Air Condition, Heating, Lighting &amp; Ventilating</topic><topic>ARC HEATERS</topic><topic>COMPARISON</topic><topic>DIRECT CURRENT</topic><topic>ENTHALPY</topic><topic>HIGH PRESSURE</topic><topic>MEASUREMENT</topic><topic>NOZZLE GAS FLOW</topic><topic>TEST EQUIPMENT</topic><topic>Test Facilities, Equipment and Methods</topic><topic>TEST METHODS</topic><topic>WIND TUNNEL TESTS</topic><toplevel>online_resources</toplevel><creatorcontrib>Horn, Dennis D</creatorcontrib><creatorcontrib>Smith, Richard T</creatorcontrib><creatorcontrib>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Horn, Dennis D</au><au>Smith, Richard T</au><aucorp>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</btitle><date>1975-11</date><risdate>1975</risdate><abstract>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented. See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA017288
source DTIC Technical Reports
subjects Air Condition, Heating, Lighting & Ventilating
ARC HEATERS
COMPARISON
DIRECT CURRENT
ENTHALPY
HIGH PRESSURE
MEASUREMENT
NOZZLE GAS FLOW
TEST EQUIPMENT
Test Facilities, Equipment and Methods
TEST METHODS
WIND TUNNEL TESTS
title Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T18%3A56%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Results%20of%20Testing%20the%20AEDC%205-MW%20Segmented%20ARC%20Heater%20at%20Pressures%20up%20to%20171%20ATM&rft.au=Horn,%20Dennis%20D&rft.aucorp=ARNOLD%20ENGINEERING%20DEVELOPMENT%20CENTER%20ARNOLD%20AFB%20TN&rft.date=1975-11&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA017288%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true