Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM
The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and en...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Horn, Dennis D Smith, Richard T |
description | The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented.
See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85. |
format | Report |
fullrecord | <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA017288</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA017288</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA0172883</originalsourceid><addsrcrecordid>eNrjZAgISi0uzSkpVshPUwhJLS7JzEtXKMlIVXB0dXFWMNX1DVcITk3PTc0rSU1RcAxyVvBITSxJLVJILFEIKEotLi4FEgqlBQol-QqG5oYKjiG-PAysaYk5xam8UJqbQcbNNcTZQzelJDM5HmRBakm8o4ujgaG5kYWFMQFpAN-wMM8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><source>DTIC Technical Reports</source><creator>Horn, Dennis D ; Smith, Richard T</creator><creatorcontrib>Horn, Dennis D ; Smith, Richard T ; ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><description>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented.
See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</description><language>eng</language><subject>Air Condition, Heating, Lighting & Ventilating ; ARC HEATERS ; COMPARISON ; DIRECT CURRENT ; ENTHALPY ; HIGH PRESSURE ; MEASUREMENT ; NOZZLE GAS FLOW ; TEST EQUIPMENT ; Test Facilities, Equipment and Methods ; TEST METHODS ; WIND TUNNEL TESTS</subject><creationdate>1975</creationdate><rights>Approved for public release; distribution is unlimited.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,27567,27568</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA017288$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Horn, Dennis D</creatorcontrib><creatorcontrib>Smith, Richard T</creatorcontrib><creatorcontrib>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><description>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented.
See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</description><subject>Air Condition, Heating, Lighting & Ventilating</subject><subject>ARC HEATERS</subject><subject>COMPARISON</subject><subject>DIRECT CURRENT</subject><subject>ENTHALPY</subject><subject>HIGH PRESSURE</subject><subject>MEASUREMENT</subject><subject>NOZZLE GAS FLOW</subject><subject>TEST EQUIPMENT</subject><subject>Test Facilities, Equipment and Methods</subject><subject>TEST METHODS</subject><subject>WIND TUNNEL TESTS</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1975</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZAgISi0uzSkpVshPUwhJLS7JzEtXKMlIVXB0dXFWMNX1DVcITk3PTc0rSU1RcAxyVvBITSxJLVJILFEIKEotLi4FEgqlBQol-QqG5oYKjiG-PAysaYk5xam8UJqbQcbNNcTZQzelJDM5HmRBakm8o4ujgaG5kYWFMQFpAN-wMM8</recordid><startdate>197511</startdate><enddate>197511</enddate><creator>Horn, Dennis D</creator><creator>Smith, Richard T</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>197511</creationdate><title>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</title><author>Horn, Dennis D ; Smith, Richard T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA0172883</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1975</creationdate><topic>Air Condition, Heating, Lighting & Ventilating</topic><topic>ARC HEATERS</topic><topic>COMPARISON</topic><topic>DIRECT CURRENT</topic><topic>ENTHALPY</topic><topic>HIGH PRESSURE</topic><topic>MEASUREMENT</topic><topic>NOZZLE GAS FLOW</topic><topic>TEST EQUIPMENT</topic><topic>Test Facilities, Equipment and Methods</topic><topic>TEST METHODS</topic><topic>WIND TUNNEL TESTS</topic><toplevel>online_resources</toplevel><creatorcontrib>Horn, Dennis D</creatorcontrib><creatorcontrib>Smith, Richard T</creatorcontrib><creatorcontrib>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Horn, Dennis D</au><au>Smith, Richard T</au><aucorp>ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AFB TN</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM</btitle><date>1975-11</date><risdate>1975</risdate><abstract>The results of testing a nominal 5-MW segmented (constrictor-channel type) arc heater are presented. The heater was operated at chamber pressures up to 171 atm and power inputs to nearly 4 MW using air as the test gas. The nozzle exit flow was surveyed with a null-point calorimeter, pressure, and enthalpy probes. Performance comparisons are made between the segmented and other types of arc heaters and with an analytical correlation program. Detailed test and data summaries are presented.
See also AD-A002 313. Prepared in cooperation with ARO, Inc., Tullahoma, TN. Rept. no. ARO-PWT-TR-75-85.</abstract><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | |
ispartof | |
issn | |
language | eng |
recordid | cdi_dtic_stinet_ADA017288 |
source | DTIC Technical Reports |
subjects | Air Condition, Heating, Lighting & Ventilating ARC HEATERS COMPARISON DIRECT CURRENT ENTHALPY HIGH PRESSURE MEASUREMENT NOZZLE GAS FLOW TEST EQUIPMENT Test Facilities, Equipment and Methods TEST METHODS WIND TUNNEL TESTS |
title | Results of Testing the AEDC 5-MW Segmented ARC Heater at Pressures up to 171 ATM |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T18%3A56%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Results%20of%20Testing%20the%20AEDC%205-MW%20Segmented%20ARC%20Heater%20at%20Pressures%20up%20to%20171%20ATM&rft.au=Horn,%20Dennis%20D&rft.aucorp=ARNOLD%20ENGINEERING%20DEVELOPMENT%20CENTER%20ARNOLD%20AFB%20TN&rft.date=1975-11&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA017288%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |