THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION

The experiment which is described in this paper involves expanded polypropylene insulation on 19-gauge wire. The wall thickness was 9 mils. The gas for the expansion of the polypropylene was supplied by the decomposition of a chemical blowing agent which was dry mixed with the plastic granules befor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bauer,E O, Fox,P E
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Bauer,E O
Fox,P E
description The experiment which is described in this paper involves expanded polypropylene insulation on 19-gauge wire. The wall thickness was 9 mils. The gas for the expansion of the polypropylene was supplied by the decomposition of a chemical blowing agent which was dry mixed with the plastic granules before being introduced into the extruder hopper. With suitable control of extrusion conditions and adequate nucleation, what appeared to be a uniform fine-cell structure was produced in the laboratory by this method. Difficulties were experienced, however, with the integrity of the insulation as evidenced by the large number of faults picked up by the spark tester on the extrusion line. Examination of the insulation revealed that there was a longitudinal seam of relatively solid material containing large air cells. In some instances the large cells were interconnected so that there was an air dielectric path from the conductor to the surface of the insulation. These points registered as faults on the spark tester and as high capacitance excursions on the capacitance monitor chart. It is the purpose of this paper to describe (1) an experiment which revealed the cause of this condition, and (2) the development of a crosshead flowpath which provided the solution to the problem. Annual Wire and Cable Symposium (10th), Asbury Park, N. J., 29 Nov 61.
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_AD0656170</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>AD0656170</sourcerecordid><originalsourceid>FETCH-dtic_stinet_AD06561703</originalsourceid><addsrcrecordid>eNrjZIgP8XBV8PRz8wl19XN2VfB3U3CNCAkKdXENUnB39fd1DQmKBEorgFQFBPm7hDqHePr7gZR5-Pv6u7v6ufqHBis4u_r4hPo4BikE-DgGh3g6A3UEA_kgpTwMrGmJOcWpvFCam0HGzTXE2UM3pSQzOb64JDMvtSTe0cXAzNTM0NzAmIA0AG7KMIc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION</title><source>DTIC Technical Reports</source><creator>Bauer,E O ; Fox,P E</creator><creatorcontrib>Bauer,E O ; Fox,P E ; BELL TELEPHONE LABS INC MURRAY HILL N J</creatorcontrib><description>The experiment which is described in this paper involves expanded polypropylene insulation on 19-gauge wire. The wall thickness was 9 mils. The gas for the expansion of the polypropylene was supplied by the decomposition of a chemical blowing agent which was dry mixed with the plastic granules before being introduced into the extruder hopper. With suitable control of extrusion conditions and adequate nucleation, what appeared to be a uniform fine-cell structure was produced in the laboratory by this method. Difficulties were experienced, however, with the integrity of the insulation as evidenced by the large number of faults picked up by the spark tester on the extrusion line. Examination of the insulation revealed that there was a longitudinal seam of relatively solid material containing large air cells. In some instances the large cells were interconnected so that there was an air dielectric path from the conductor to the surface of the insulation. These points registered as faults on the spark tester and as high capacitance excursions on the capacitance monitor chart. It is the purpose of this paper to describe (1) an experiment which revealed the cause of this condition, and (2) the development of a crosshead flowpath which provided the solution to the problem. Annual Wire and Cable Symposium (10th), Asbury Park, N. J., 29 Nov 61.</description><language>eng</language><subject>DIES ; Electrical and Electronic Equipment ; ELECTRICAL INSULATION ; EXPANDED PLASTICS ; EXTRUSION ; GEOMETRY ; Miscellaneous Materials ; PLASTIC COATINGS ; Plastics</subject><creationdate>1961</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,778,883,27550,27551</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/AD0656170$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Bauer,E O</creatorcontrib><creatorcontrib>Fox,P E</creatorcontrib><creatorcontrib>BELL TELEPHONE LABS INC MURRAY HILL N J</creatorcontrib><title>THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION</title><description>The experiment which is described in this paper involves expanded polypropylene insulation on 19-gauge wire. The wall thickness was 9 mils. The gas for the expansion of the polypropylene was supplied by the decomposition of a chemical blowing agent which was dry mixed with the plastic granules before being introduced into the extruder hopper. With suitable control of extrusion conditions and adequate nucleation, what appeared to be a uniform fine-cell structure was produced in the laboratory by this method. Difficulties were experienced, however, with the integrity of the insulation as evidenced by the large number of faults picked up by the spark tester on the extrusion line. Examination of the insulation revealed that there was a longitudinal seam of relatively solid material containing large air cells. In some instances the large cells were interconnected so that there was an air dielectric path from the conductor to the surface of the insulation. These points registered as faults on the spark tester and as high capacitance excursions on the capacitance monitor chart. It is the purpose of this paper to describe (1) an experiment which revealed the cause of this condition, and (2) the development of a crosshead flowpath which provided the solution to the problem. Annual Wire and Cable Symposium (10th), Asbury Park, N. J., 29 Nov 61.</description><subject>DIES</subject><subject>Electrical and Electronic Equipment</subject><subject>ELECTRICAL INSULATION</subject><subject>EXPANDED PLASTICS</subject><subject>EXTRUSION</subject><subject>GEOMETRY</subject><subject>Miscellaneous Materials</subject><subject>PLASTIC COATINGS</subject><subject>Plastics</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1961</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZIgP8XBV8PRz8wl19XN2VfB3U3CNCAkKdXENUnB39fd1DQmKBEorgFQFBPm7hDqHePr7gZR5-Pv6u7v6ufqHBis4u_r4hPo4BikE-DgGh3g6A3UEA_kgpTwMrGmJOcWpvFCam0HGzTXE2UM3pSQzOb64JDMvtSTe0cXAzNTM0NzAmIA0AG7KMIc</recordid><startdate>196111</startdate><enddate>196111</enddate><creator>Bauer,E O</creator><creator>Fox,P E</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>196111</creationdate><title>THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION</title><author>Bauer,E O ; Fox,P E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_AD06561703</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1961</creationdate><topic>DIES</topic><topic>Electrical and Electronic Equipment</topic><topic>ELECTRICAL INSULATION</topic><topic>EXPANDED PLASTICS</topic><topic>EXTRUSION</topic><topic>GEOMETRY</topic><topic>Miscellaneous Materials</topic><topic>PLASTIC COATINGS</topic><topic>Plastics</topic><toplevel>online_resources</toplevel><creatorcontrib>Bauer,E O</creatorcontrib><creatorcontrib>Fox,P E</creatorcontrib><creatorcontrib>BELL TELEPHONE LABS INC MURRAY HILL N J</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Bauer,E O</au><au>Fox,P E</au><aucorp>BELL TELEPHONE LABS INC MURRAY HILL N J</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION</btitle><date>1961-11</date><risdate>1961</risdate><abstract>The experiment which is described in this paper involves expanded polypropylene insulation on 19-gauge wire. The wall thickness was 9 mils. The gas for the expansion of the polypropylene was supplied by the decomposition of a chemical blowing agent which was dry mixed with the plastic granules before being introduced into the extruder hopper. With suitable control of extrusion conditions and adequate nucleation, what appeared to be a uniform fine-cell structure was produced in the laboratory by this method. Difficulties were experienced, however, with the integrity of the insulation as evidenced by the large number of faults picked up by the spark tester on the extrusion line. Examination of the insulation revealed that there was a longitudinal seam of relatively solid material containing large air cells. In some instances the large cells were interconnected so that there was an air dielectric path from the conductor to the surface of the insulation. These points registered as faults on the spark tester and as high capacitance excursions on the capacitance monitor chart. It is the purpose of this paper to describe (1) an experiment which revealed the cause of this condition, and (2) the development of a crosshead flowpath which provided the solution to the problem. Annual Wire and Cable Symposium (10th), Asbury Park, N. J., 29 Nov 61.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_AD0656170
source DTIC Technical Reports
subjects DIES
Electrical and Electronic Equipment
ELECTRICAL INSULATION
EXPANDED PLASTICS
EXTRUSION
GEOMETRY
Miscellaneous Materials
PLASTIC COATINGS
Plastics
title THE INFLUENCE OF EXTRUDER GEOMETRY IN THE PRODUCTION OF HOMOGENEOUS CELLULAR PLASTIC INSULATION
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T16%3A38%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=THE%20INFLUENCE%20OF%20EXTRUDER%20GEOMETRY%20IN%20THE%20PRODUCTION%20OF%20HOMOGENEOUS%20CELLULAR%20PLASTIC%20INSULATION&rft.au=Bauer,E%20O&rft.aucorp=BELL%20TELEPHONE%20LABS%20INC%20MURRAY%20HILL%20N%20J&rft.date=1961-11&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EAD0656170%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true