SCATTERED RADIATION FROM A COBALT-60 SOURCE IN A BRICK STRUCTURE
The scattered component of cobalt-60 radiation produced in a brick structure was determined. An end-window scintillation detector, connected to a 400-channel, pulseheight analyzer, and associated readout equipment were utilized for this study. It was found that a scatter component of 2.7% to 12.4% o...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The scattered component of cobalt-60 radiation produced in a brick structure was determined. An end-window scintillation detector, connected to a 400-channel, pulseheight analyzer, and associated readout equipment were utilized for this study. It was found that a scatter component of 2.7% to 12.4% of the emitted radiation was produced by the brick walls and concrete floor of the magnesium cell. The scatter component can be extremely significant where dosimeters with enhanced, low-energy responses are used. (Author) |
---|