OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS
Transient radiation effects tests on silicon controlled rectifiers, associated Minuteman circuits, and tantalum and aluminum electrolytic capacitors were performed at the Godiva III prompt critical assembly, Los Alamos, New Mexico, on Oct. 27 and 28, 1960. Fourteen out of 31 SCR's exhibited fir...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Lubatti,H J Wicklein,H W |
description | Transient radiation effects tests on silicon controlled rectifiers, associated Minuteman circuits, and tantalum and aluminum electrolytic capacitors were performed at the Godiva III prompt critical assembly, Los Alamos, New Mexico, on Oct. 27 and 28, 1960. Fourteen out of 31 SCR's exhibited firing at gamma radiation rates between 6 x 10 to the 5th power and 3 x 10 to the 6th power r/sec. The gamma-induced SCR leakage current at firing generally exceeded twice the initial holding current of the device. A possible method for predicting gamma rates for firing SCR's is indicated. An empirical relationship for dependence of SCR leakage current on gamma rate was determined, as I sub c = (6 = 3) x 10 to the minus 10 power and phi to the 1.2 plus or minus 0.1 power. Leakage resistance change factors as low as 3.6 x 10 to the minus 8 power and 2.6 x 10 to the minus 7 power for tantalum and aluminum electrolytic capacitors, respectively, were noted at gamma radiation rates up to 4.5 x 10 to the 7th power r/sec. A relationship between capacitor leakage resistance (R in ohms), capacitance (C in farads), and gamma radiation rate was determined at R = G/phi C, where C = 2.1 x 10 to the 5th power for aluminum foil capacitors, 3.29 x 10 to the 5th power for tantalum foil capacitors, and 1.81 x 10 to the 5th power for tantalum solid electrolyte capacitors. (Author) |
format | Report |
fullrecord | <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_AD0427277</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>AD0427277</sourcerecordid><originalsourceid>FETCH-dtic_stinet_AD04272773</originalsourceid><addsrcrecordid>eNrjZLDzdw7xd3IN0lEwtDQz0FFw93fxDHNU8PT0VNDVVfD19AsNcfV19FMIcnTxdAzx9PdTcHVzc3UOCVYIcQ0OCeZhYE1LzClO5YXS3Awybq4hzh66KSWZyfHFJZl5qSXxji4GJkbmRubmxgSkAT2YJjo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS</title><source>DTIC Technical Reports</source><creator>Lubatti,H J ; Wicklein,H W</creator><creatorcontrib>Lubatti,H J ; Wicklein,H W ; BOEING CO SEATTLE WASH</creatorcontrib><description>Transient radiation effects tests on silicon controlled rectifiers, associated Minuteman circuits, and tantalum and aluminum electrolytic capacitors were performed at the Godiva III prompt critical assembly, Los Alamos, New Mexico, on Oct. 27 and 28, 1960. Fourteen out of 31 SCR's exhibited firing at gamma radiation rates between 6 x 10 to the 5th power and 3 x 10 to the 6th power r/sec. The gamma-induced SCR leakage current at firing generally exceeded twice the initial holding current of the device. A possible method for predicting gamma rates for firing SCR's is indicated. An empirical relationship for dependence of SCR leakage current on gamma rate was determined, as I sub c = (6 = 3) x 10 to the minus 10 power and phi to the 1.2 plus or minus 0.1 power. Leakage resistance change factors as low as 3.6 x 10 to the minus 8 power and 2.6 x 10 to the minus 7 power for tantalum and aluminum electrolytic capacitors, respectively, were noted at gamma radiation rates up to 4.5 x 10 to the 7th power r/sec. A relationship between capacitor leakage resistance (R in ohms), capacitance (C in farads), and gamma radiation rate was determined at R = G/phi C, where C = 2.1 x 10 to the 5th power for aluminum foil capacitors, 3.29 x 10 to the 5th power for tantalum foil capacitors, and 1.81 x 10 to the 5th power for tantalum solid electrolyte capacitors. (Author)</description><language>eng</language><subject>ALUMINUM ; DAMAGE ; DOSE RATE ; DOSIMETERS ; FOILS(MATERIALS) ; GAMMA RAYS ; GUIDED MISSILE COMPONENTS ; MEASUREMENT ; MINUTEMAN ; RECTIFIERS ; SURFACE TO SURFACE MISSILES ; TABLES(DATA) ; TANTALUM ; TEST METHODS ; TRANSIENT RADIATION EFFECTS(ELECTRONICS)</subject><creationdate>1960</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,776,881,27546,27547</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/AD0427277$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Lubatti,H J</creatorcontrib><creatorcontrib>Wicklein,H W</creatorcontrib><creatorcontrib>BOEING CO SEATTLE WASH</creatorcontrib><title>OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS</title><description>Transient radiation effects tests on silicon controlled rectifiers, associated Minuteman circuits, and tantalum and aluminum electrolytic capacitors were performed at the Godiva III prompt critical assembly, Los Alamos, New Mexico, on Oct. 27 and 28, 1960. Fourteen out of 31 SCR's exhibited firing at gamma radiation rates between 6 x 10 to the 5th power and 3 x 10 to the 6th power r/sec. The gamma-induced SCR leakage current at firing generally exceeded twice the initial holding current of the device. A possible method for predicting gamma rates for firing SCR's is indicated. An empirical relationship for dependence of SCR leakage current on gamma rate was determined, as I sub c = (6 = 3) x 10 to the minus 10 power and phi to the 1.2 plus or minus 0.1 power. Leakage resistance change factors as low as 3.6 x 10 to the minus 8 power and 2.6 x 10 to the minus 7 power for tantalum and aluminum electrolytic capacitors, respectively, were noted at gamma radiation rates up to 4.5 x 10 to the 7th power r/sec. A relationship between capacitor leakage resistance (R in ohms), capacitance (C in farads), and gamma radiation rate was determined at R = G/phi C, where C = 2.1 x 10 to the 5th power for aluminum foil capacitors, 3.29 x 10 to the 5th power for tantalum foil capacitors, and 1.81 x 10 to the 5th power for tantalum solid electrolyte capacitors. (Author)</description><subject>ALUMINUM</subject><subject>DAMAGE</subject><subject>DOSE RATE</subject><subject>DOSIMETERS</subject><subject>FOILS(MATERIALS)</subject><subject>GAMMA RAYS</subject><subject>GUIDED MISSILE COMPONENTS</subject><subject>MEASUREMENT</subject><subject>MINUTEMAN</subject><subject>RECTIFIERS</subject><subject>SURFACE TO SURFACE MISSILES</subject><subject>TABLES(DATA)</subject><subject>TANTALUM</subject><subject>TEST METHODS</subject><subject>TRANSIENT RADIATION EFFECTS(ELECTRONICS)</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1960</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZLDzdw7xd3IN0lEwtDQz0FFw93fxDHNU8PT0VNDVVfD19AsNcfV19FMIcnTxdAzx9PdTcHVzc3UOCVYIcQ0OCeZhYE1LzClO5YXS3Awybq4hzh66KSWZyfHFJZl5qSXxji4GJkbmRubmxgSkAT2YJjo</recordid><startdate>19601212</startdate><enddate>19601212</enddate><creator>Lubatti,H J</creator><creator>Wicklein,H W</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>19601212</creationdate><title>OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS</title><author>Lubatti,H J ; Wicklein,H W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_AD04272773</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1960</creationdate><topic>ALUMINUM</topic><topic>DAMAGE</topic><topic>DOSE RATE</topic><topic>DOSIMETERS</topic><topic>FOILS(MATERIALS)</topic><topic>GAMMA RAYS</topic><topic>GUIDED MISSILE COMPONENTS</topic><topic>MEASUREMENT</topic><topic>MINUTEMAN</topic><topic>RECTIFIERS</topic><topic>SURFACE TO SURFACE MISSILES</topic><topic>TABLES(DATA)</topic><topic>TANTALUM</topic><topic>TEST METHODS</topic><topic>TRANSIENT RADIATION EFFECTS(ELECTRONICS)</topic><toplevel>online_resources</toplevel><creatorcontrib>Lubatti,H J</creatorcontrib><creatorcontrib>Wicklein,H W</creatorcontrib><creatorcontrib>BOEING CO SEATTLE WASH</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Lubatti,H J</au><au>Wicklein,H W</au><aucorp>BOEING CO SEATTLE WASH</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS</btitle><date>1960-12-12</date><risdate>1960</risdate><abstract>Transient radiation effects tests on silicon controlled rectifiers, associated Minuteman circuits, and tantalum and aluminum electrolytic capacitors were performed at the Godiva III prompt critical assembly, Los Alamos, New Mexico, on Oct. 27 and 28, 1960. Fourteen out of 31 SCR's exhibited firing at gamma radiation rates between 6 x 10 to the 5th power and 3 x 10 to the 6th power r/sec. The gamma-induced SCR leakage current at firing generally exceeded twice the initial holding current of the device. A possible method for predicting gamma rates for firing SCR's is indicated. An empirical relationship for dependence of SCR leakage current on gamma rate was determined, as I sub c = (6 = 3) x 10 to the minus 10 power and phi to the 1.2 plus or minus 0.1 power. Leakage resistance change factors as low as 3.6 x 10 to the minus 8 power and 2.6 x 10 to the minus 7 power for tantalum and aluminum electrolytic capacitors, respectively, were noted at gamma radiation rates up to 4.5 x 10 to the 7th power r/sec. A relationship between capacitor leakage resistance (R in ohms), capacitance (C in farads), and gamma radiation rate was determined at R = G/phi C, where C = 2.1 x 10 to the 5th power for aluminum foil capacitors, 3.29 x 10 to the 5th power for tantalum foil capacitors, and 1.81 x 10 to the 5th power for tantalum solid electrolyte capacitors. (Author)</abstract><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | |
ispartof | |
issn | |
language | eng |
recordid | cdi_dtic_stinet_AD0427277 |
source | DTIC Technical Reports |
subjects | ALUMINUM DAMAGE DOSE RATE DOSIMETERS FOILS(MATERIALS) GAMMA RAYS GUIDED MISSILE COMPONENTS MEASUREMENT MINUTEMAN RECTIFIERS SURFACE TO SURFACE MISSILES TABLES(DATA) TANTALUM TEST METHODS TRANSIENT RADIATION EFFECTS(ELECTRONICS) |
title | OCTOBER, 1960, GODIVA III -- MINUTEMAN RADIATION EFFECTS TESTS |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T22%3A16%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=OCTOBER,%201960,%20GODIVA%20III%20--%20MINUTEMAN%20RADIATION%20EFFECTS%20TESTS&rft.au=Lubatti,H%20J&rft.aucorp=BOEING%20CO%20SEATTLE%20WASH&rft.date=1960-12-12&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EAD0427277%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |