Measuring Effectiveness of Metamorphic Relations for Image Processing Using Mutation Testing
Testing an intricate plexus of advanced software system architecture is quite challenging due to the absence of test oracle. Metamorphic testing is a popular technique to alleviate the test oracle problem. The effectiveness of metamorphic testing is dependent on metamorphic relations (MRs). MRs repr...
Gespeichert in:
Veröffentlicht in: | Journal of imaging 2024-04, Vol.10 (4), p.87 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Testing an intricate plexus of advanced software system architecture is quite challenging due to the absence of test oracle. Metamorphic testing is a popular technique to alleviate the test oracle problem. The effectiveness of metamorphic testing is dependent on metamorphic relations (MRs). MRs represent the essential properties of the system under test and are evaluated by their fault detection rates. The existing techniques for the evaluation of MRs are not comprehensive, as very few mutation operators are used to generate very few mutants. In this research, we have proposed six new MRs for dilation and erosion operations. The fault detection rate of six newly proposed MRs is determined using mutation testing. We have used eight applicable mutation operators and determined their effectiveness. By using these applicable operators, we have ensured that all the possible numbers of mutants are generated, which shows that all the faults in the system under test are fully identified. Results of the evaluation of four MRs for edge detection show an improvement in all the respective MRs, especially in MR
and MR
, with a fault detection rate of 76.54% and 69.13%, respectively, which is 32% and 24% higher than the existing technique. The fault detection rate of MR
and MR
is also improved by 1%. Similarly, results of dilation and erosion show that out of 8 MRs, the fault detection rates of four MRs are higher than the existing technique. In the proposed technique, MR
is improved by 39%, MR
is improved by 0.5%, MR
is improved by 17%, and MR
is improved by 29%. We have also compared the results of our proposed MRs with the existing MRs of dilation and erosion operations. Results show that the proposed MRs complement the existing MRs effectively as the new MRs can find those faults that are not identified by the existing MRs. |
---|---|
ISSN: | 2313-433X 2313-433X |
DOI: | 10.3390/jimaging10040087 |