Explantation of an ALTO abdominal stent graft

Explantation of traditional infrarenal aortic endografts has been previously described, and explanation of aortic endografts with standard suprarenal fixation at our center has been well defined. However, to the best of our knowledge, no cases have been reported on explantation of endografts with po...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of vascular surgery cases and innovative techniques 2024-04, Vol.10 (2), p.101416, Article 101416
Hauptverfasser: Schoephoerster, Carl T., Rajaei, Mohammad H., Rossi, Peter J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Explantation of traditional infrarenal aortic endografts has been previously described, and explanation of aortic endografts with standard suprarenal fixation at our center has been well defined. However, to the best of our knowledge, no cases have been reported on explantation of endografts with polymer rings present to facilitate the proximal seal. By obtaining full thoracoabdominal exposure with supraceliac clamping and opening the entire aorta along the graft, we were able to successfully explant the ALTO stent graft with polymer rings.
ISSN:2468-4287
2468-4287
DOI:10.1016/j.jvscit.2023.101416