Influence of pH on Source Term of Activated Corrosion Product in Reactor

Activated corrosion product is an important radioactive source term in the primary circuit of pressurized water reactor, which has an important influence on reactor shielding design, personnel protection and accident safety. As a key parameter of pressurized water reactor (PWR) coolant, its pH value...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Yuanzineng kexue jishu 2022-12, Vol.56 (12), p.2498-2507
Hauptverfasser: LI Pinglie, ZHANG Jingyu, YANG Hongxin, TAN Lin, ZHAO Xiaoze, XIAO Yixin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Activated corrosion product is an important radioactive source term in the primary circuit of pressurized water reactor, which has an important influence on reactor shielding design, personnel protection and accident safety. As a key parameter of pressurized water reactor (PWR) coolant, its pH value plays an important role in the process of material corrosion, dissolution and precipitation of corrosion products. The solubility of corrosion products and the corrosion rate of materials in the coolant can be controlled by adjusting the pH value by coordinating the concentration of boronlithium in the coolant, so as to achieve the purpose of controlling the source term of activated corrosion products. At present, the influence of pH value on the corrosion rate of materials and the solubility of corrosion products is more analyzed in the world. The influence of pH value on the radioactive source terms was described in varying degrees through experiments and feedback data of nuclear power plant operation. However, the cost of obtaining power plant operation data is high, so it is of great application significance to analyze the influence of pH value on radioactive source term from the perspective of simulation calculation. In this paper, the solubility of corrosion products and the corrosion rate of materials under different pH values were calculated, and the radioactive activity in each area of the primary circuit of PWR under different pH values was calculated by substituting it into the selfdeveloped source term analysis CATE code of activated corrosion products. After systematic research and analysis, it is concluded that when the pH value is 56 to 74, the solubility of corrosion products decreases continuously with the increase of pH value, and the decreasing range gradually becomes slow. The corrosion rate of 304 stainless steel decreases with the increase of pH value and reaches a balance after decreasing to a small value. The corrosion rate of Inconel decreases with the increase of pH value, and the decrease amplitude gradually becomes slow. With pH value increasing, the radioactive activity decreases, when the pH value increases to 7.2 or so, the radioactive activity decreases slower, when the pH value is 74, the radioactive activity in the core, steam generator and coolant decreases slightly compared with that when the pH value is 72, but the radioactive activity in coolant pump, transition section and cold pipe section increases slightly. pH val
ISSN:1000-6931