STUDY ON NEUTRON – GAMMA PULSE SHAPE DISCRIMINATION ALGORITHMS FOR SCINTILLATION DETECTOR
The four neutron - gamma pulsed shape discrimination algorithms for the model NE213 scintillation detector by using digital signal processing were developed. In this study, a pulse generator, pulse digitizer and neutron - gamma pulsed shape discrimination algorithms are simulated in Matlab, Simulink...
Gespeichert in:
Veröffentlicht in: | Tạp chí Khoa học Đại học Đà Lạt 2016-09, Vol.6 (3), p.281-292 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The four neutron - gamma pulsed shape discrimination algorithms for the model NE213 scintillation detector by using digital signal processing were developed. In this study, a pulse generator, pulse digitizer and neutron - gamma pulsed shape discrimination algorithms are simulated in Matlab, Simulink software. The results obtained show that the method to rise-time discrimination has a quality factor (Figure-of-Merits: FOM=1.09), pulsed gradient analysis method (FOM = 0.66), charge comparison method (FOM = 2.21), and correlation pattern method (FOM = 1.97). This result is the basis for building systems for measurements of neutron using scintillation detectors. |
---|---|
ISSN: | 0866-787X 0866-787X |
DOI: | 10.37569/DalatUniversity.6.3.72(2016) |