A single-center prospective study evaluating the usefulness of artificial intelligence for the diagnosis of esophageal squamous cell carcinoma in a real-time setting

Several pre-clinical studies have reported the usefulness of artificial intelligence (AI) systems in the diagnosis of esophageal squamous cell carcinoma (ESCC). We conducted this study to evaluate the usefulness of an AI system for real-time diagnosis of ESCC in a clinical setting. This study follow...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC gastroenterology 2023-05, Vol.23 (1), p.184-184, Article 184
Hauptverfasser: Tani, Yasuhiro, Ishihara, Ryu, Inoue, Takahiro, Okubo, Yuki, Kawakami, Yushi, Matsueda, Katsunori, Miyake, Muneaki, Yoshii, Shunsuke, Shichijo, Satoki, Kanesaka, Takashi, Yamamoto, Sachiko, Takeuchi, Yoji, Higashino, Koji, Uedo, Noriya, Michida, Tomoki, Kato, Yusuke, Tada, Tomohiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Several pre-clinical studies have reported the usefulness of artificial intelligence (AI) systems in the diagnosis of esophageal squamous cell carcinoma (ESCC). We conducted this study to evaluate the usefulness of an AI system for real-time diagnosis of ESCC in a clinical setting. This study followed a single-center prospective single-arm non-inferiority design. Patients at high risk for ESCC were recruited and real-time diagnosis by the AI system was compared with that of endoscopists for lesions suspected to be ESCC. The primary outcomes were the diagnostic accuracy of the AI system and endoscopists. The secondary outcomes were sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and adverse events. A total of 237 lesions were evaluated. The accuracy, sensitivity, and specificity of the AI system were 80.6%, 68.2%, and 83.4%, respectively. The accuracy, sensitivity, and specificity of endoscopists were 85.7%, 61.4%, and 91.2%, respectively. The difference between the accuracy of the AI system and that of the endoscopists was - 5.1%, and the lower limit of the 90% confidence interval was less than the non-inferiority margin. The non-inferiority of the AI system in comparison with endoscopists in the real-time diagnosis of ESCC in a clinical setting was not proven. Japan Registry of Clinical Trials (jRCTs052200015, 18/05/2020).
ISSN:1471-230X
1471-230X
DOI:10.1186/s12876-023-02788-2