Assessment of renal hemodynamic toxicity of fluid challenge with 0.9% NaCl compared to balanced crystalloid (PlasmaLyte®) in a rat model with severe sepsis
Background According to international guidelines, volume expansion with crystalloids is the first-line treatment for hemodynamic management in patients with severe sepsis or septic shock. Compared to balanced crystalloids, 0.9% sodium chloride (0.9% NaCl) induces hyperchloremia and metabolic acidosi...
Gespeichert in:
Veröffentlicht in: | Annals of intensive care 2017-06, Vol.7 (1), p.66-8, Article 66 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
According to international guidelines, volume expansion with crystalloids is the first-line treatment for hemodynamic management in patients with severe sepsis or septic shock. Compared to balanced crystalloids, 0.9% sodium chloride (0.9% NaCl) induces hyperchloremia and metabolic acidosis and may alter renal hemodynamics and function. We compared the effects of 0.9% NaCl to a less chloride-concentrated fluid, PlasmaLyte
®
(PL) in targeted fluid resuscitation in a randomized, double-blind controlled study in an experimental model of severe sepsis in rats.
Results
A sepsis with hypotension was induced by cecal ligature and puncture (CLP) in 40 male Wistar rats (20 for each crystalloid). Rats received fluid resuscitation over a period of 200 min for a targeted mean arterial pressure of 90 mm Hg. Animals received similar volumes of 0.9% NaCl or PL. Unlike PL-resuscitated rats, 0.9% NaCl-resuscitated rats experienced hyperchloremia and metabolic acidosis, whereas systemic hemodynamics, renal hemodynamics and renal function were not significantly different between both groups.
Conclusion
In our model of rats with severe sepsis resuscitated with large amounts of crystalloids, 0.9% NaCl-induced hyperchloremic acidosis, but balanced crystalloid did not improve systemic and renal hemodynamics or renal function. |
---|---|
ISSN: | 2110-5820 2110-5820 |
DOI: | 10.1186/s13613-017-0286-1 |