The interaction between irreversible electroporation therapy (IRE) and embolization material using a validated vegetal model: an experimental study

Irreversible electroporation (IRE) is a nonthermal tumor ablation technique that induces cell apoptosis while preserving extracellular architecture. Surgical clips and embolic agents may lie adjacent to, or within, the target lesion. It is unknown to date if IRE causes degradation to the embolic age...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and interventional radiology (Ankara, Turkey) Turkey), 2019-07, Vol.25 (4), p.304-309
Hauptverfasser: Chan, Philip, McLean, Catriona, Chan, Stephen, Goh, Gerard S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Irreversible electroporation (IRE) is a nonthermal tumor ablation technique that induces cell apoptosis while preserving extracellular architecture. Surgical clips and embolic agents may lie adjacent to, or within, the target lesion. It is unknown to date if IRE causes degradation to the embolic agents or surgical clips that may have adverse effects to patients. We aimed to examine the effects of the IRE on the morphology of various embolic agents and the effects of these agents to the ablation field using a previously validated vegetal model. Metallic surgical clips and various metallic and nonmetallic embolic agents were inserted within the center of the tuber ablation field. Additionally, clips were inserted on the edge and outside the ablation field. One tuber was ablated as a control. Ablation settings were based on previous published experiments. Tubers were imaged with magnetic resonance imaging (MRI) 18-24 hours after ablation and the ablated field dimensions were measured. Nonmetallic embolic agents were examined microscopically by the pathologist. Nonmetallic agents did not affect the ablation pattern. Metallic implants, however, caused arcing of the ablation margins. There was no macroscopic or microscopic degradation to the agents after IRE. The ablation zone arced in the presence of surgical clips at the edge or outside the ablation margins; therefore, nearby critical structures may be susceptible to the effects of IRE. Furthermore, there was no physical degradation of the embolic agents or surgical clips, and this may have importance when considering IRE ablation of previously embolized lesions in vivo.
ISSN:1305-3612
1305-3825
1305-3612
DOI:10.5152/dir.2019.18361