Pulmonary venous baffle obstruction following senning procedure - Role of transesophageal echocardiography
We present a case of D-transposition of great arteries with atrial septal defect and patent ductus arteriosus electively posted for Senning's operation at 10 months of age. The patient developed signs of lung congestion immediately after termination of cardiopulmonary bypass. A stenosis in the...
Gespeichert in:
Veröffentlicht in: | Annals of cardiac anaesthesia 2020-04, Vol.23 (2), p.232-234 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present a case of D-transposition of great arteries with atrial septal defect and patent ductus arteriosus electively posted for Senning's operation at 10 months of age. The patient developed signs of lung congestion immediately after termination of cardiopulmonary bypass. A stenosis in the pulmonary venous baffle was detected in transesophageal echocardiography showing a peak gradient of 10 mmHg and a mean gradient of 5 mmHg. Hence, revision of baffle was planned. The stenotic area was excised and augmented with homologous pericardium. Post-correction, lung compliance improved and the peak and mean gradient decreased to 3 and 1 mm Hg, respectively. The patient was extubated in the intensive care unit after 36 h and shifted to ward after 5 days with stable hemodynamics. |
---|---|
ISSN: | 0971-9784 0974-5181 |
DOI: | 10.4103/aca.ACA_195_18 |