Liquid-liquid extraction combined with high performance liquid chromatography-diode array-ultra-violet for simultaneous determination of antineoplastic drugs in plasma
A liquid-liquid extraction (LLE) combined with high-performance liquid chromatography-diode array detection method for simultaneous analysis of four chemically and structurally different antineoplastic drugs (cyclophosphamide, doxorubicin, 5-fluorouracil and ifosfamide) was developed. The assay was...
Gespeichert in:
Veröffentlicht in: | Brazilian Journal of Pharmaceutical Sciences 2011-06, Vol.47 (2), p.363-371 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A liquid-liquid extraction (LLE) combined with high-performance liquid chromatography-diode array detection method for simultaneous analysis of four chemically and structurally different antineoplastic drugs (cyclophosphamide, doxorubicin, 5-fluorouracil and ifosfamide) was developed. The assay was performed by isocratic elution, with a C18 column (5 µm, 250 x 4.6 mm) and mobile phase constituted by water pH 4.0- acetonitrile-methanol (68:19:13, v/v/v), which allowed satisfactory separation of the compounds of interest. LLE, with ethyl acetate, was used for sample clean-up with recoveries ranging from 60 to 98%. The linear ranges were from 0.5 to 100 µg mL-1, for doxorubicin and 1 to 100 µg mL-1, for the other compounds. The relative standard deviations ranged from 5.5 to 17.7%. This method is a fast and simple alternative that can be used, simultaneously, for the determination of the four drugs in plasma, with a range enabling quantification of the drugs in pharmacokinetics, bioequivalence and therapeutic drug-monitoring studies.
Um método de extração líquido-líquido (ELL) combinado com cromatografia líquida de alta eficiência-detector de arranjo de diodos foi desenvolvido para análise simultânea de quatro fármacos antineoplásicos quimicamente e estruturalmente diferentes (ciclofosfamida, doxorrubicina, fluoruracila e ifosfamida). O estudo foi realizado sob condições isocráticas, com coluna C18 (5µm, 250 x 4.6 mm) e fase móvel constituída por água pH 4.0-acetonitrila-metanol (68:19:13, v/v/v), que permitiu separação satisfatória dos analitos de interesse. A ELL, com acetato de etila, foi utilizada para limpeza da amostra, com recuperação variando de 60 a 98%. As faixas foram lineares de 0,5 a 100 µg mL-1 para doxorrubicina e 1 a 100 µg mL-1 para os outros compostos. O desvio padrão relativo variou de 5,5 a 17,7%. Este método é uma alternativa rápida e simples que pode ser usado, simultaneamente, para a determinação dos quatro fármacos em plasma, com uma faixa que permite quantificá-los em estudos de farmacocinética, bioequivalência e monitorização terapêutica. |
---|---|
ISSN: | 1984-8250 2175-9790 1984-8250 2175-9790 |
DOI: | 10.1590/S1984-82502011000200017 |