Nanoparticle-Modified 3D-Printed Denture Base Resins: Influence of Denture Cleansers on the Color Stability and Surface Roughness In Vitro

This study aimed to evaluate the influence of denture cleansers on the color, stability, and surface roughness of three-dimensional (3D)-printed denture base resins modified with zirconium dioxide nanoparticles (nano-ZrO ). A total of 440 specimens were fabricated using one heat-polymerized resin, a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nanomaterials (Basel, Switzerland) Switzerland), 2024-05, Vol.14 (10), p.891
Hauptverfasser: Gad, Mohammed M, Khattar, Abdulrahman, Alramadan, Doha M, Al Dawood, Zainab H, Al Shehab, Sujood S, Al Zaher, Rabab H, Alzain, Layal Osama, Khan, Soban Q, Abdelfattah, Mohamed Y
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to evaluate the influence of denture cleansers on the color, stability, and surface roughness of three-dimensional (3D)-printed denture base resins modified with zirconium dioxide nanoparticles (nano-ZrO ). A total of 440 specimens were fabricated using one heat-polymerized resin, and two 3D-printed resins (NextDent and ASIGA). According to the nano-ZrO content, the specimens for each resin were divided into five groups (0%, 0.5%wt, 1%wt, 3%wt, and 5%wt). Each concentration was divided into four subgroups (n = 10) based on the immersion solution (distilled water, sodium hypochlorite, Corega, and Fittydent) and immersion duration (360 and 720 days). The color changes (∆E ) and surface roughness (Ra, µm) of each specimen were measured at different time intervals (base line, 360 days, 720 days) using a spectrophotometer and a non-contact profilometer, respectively. The results were statistically analyzed using ANOVA and a post hoc Tukey's test (α = 0.05). Sodium hypochlorite showed the highest significant color change of all the denture base resins ( < 0.001). The average value of ΔE for sodium hypochlorite was significantly higher than the values for the other solutions (Fittydent, Corega, and water) ( < 0.001). Color stability was significantly affected by immersion time for all types of solutions except Corega ( < 0.001). All of the tested immersion solutions (distilled water, sodium hypochlorite, Corega, and Fittydent) showed a significant increase in the surface roughness of all the denture base resins ( < 0.05). Surface roughness was substantially increased by immersion time for all types of solution except Fittydent ( < 0.001). Denture cleansers can result in substantial color change and affect the surface roughness of unmodified and nanoparticle-modified denture base resins. Therefore, the selection of denture cleanser and appropriate types of material is critical for denture longevity.
ISSN:2079-4991
2079-4991
DOI:10.3390/nano14100891