Application of RP-HPLC method for the simultaneous determination of cetirizine in the presence of quinolones
Background Present work describes a fast, simple, and sensitive procedure for the simultaneous determination of cetirizine in the presence of quinolones using diclofenac sodium as an internal standard. The present work was designed to analyze these compounds in pharmaceutical and clinical labs being...
Gespeichert in:
Veröffentlicht in: | Future Journal of Pharmaceutical Sciences 2021-06, Vol.7 (1), p.117-6, Article 117 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Present work describes a fast, simple, and sensitive procedure for the simultaneous determination of cetirizine in the presence of quinolones using diclofenac sodium as an internal standard. The present work was designed to analyze these compounds in pharmaceutical and clinical labs being economical for use.
Results
The mobile phase consisted of the simple composition of methanol, acetonitrile, and water in a ratio of 50:20:30 with a pH adjusted to 3.1 at a flow rate of 1 mL min
−1
. The UV detection was performed at 225 nm. The linearity was assessed over the range of 2.5–50 μg mL
−1
for all drugs. The parameters such as accuracy, precision, linearity (>0.999), and sensitivity were satisfactory.
Conclusion
The method was equally applicable for formulation and human serum with recovery values between 95 and 105%. The results of the method were validated statistically according to ICH guidelines. |
---|---|
ISSN: | 2314-7253 2314-7245 2314-7253 |
DOI: | 10.1186/s43094-021-00270-y |