Evaluation of multiplex ARMS-PCR for detection of Helicobacter pylori mutations conferring resistance to clarithromycin and levofloxacin
bacterium is a major cause of gastritis. With increasing use of antibiotics to treat infections, mutation resistant strains have emerged in most human populations. To effectively treat patients to help resolve infections, the clinician needs information on the antibiotic susceptibility profile of th...
Gespeichert in:
Veröffentlicht in: | Gut pathogens 2020-07, Vol.12 (1), p.35-35, Article 35 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | bacterium is a major cause of gastritis. With increasing use of antibiotics to treat infections, mutation resistant strains have emerged in most human populations. To effectively treat patients to help resolve infections, the clinician needs information on the antibiotic susceptibility profile of the infection. Therefore, a rapid and accurate test is required to provide this information. To address this issue, we designed and validated a real time multiplex ARMS-PCR assay for rapid detection of highly prevalent
clarithromycin and levofloxacin resistance mutations. The aim of the study was to evaluate the analytical and diagnostic sensitivity and specificity of ARMS-PCR, using direct Sanger sequencing of the known resistance mutations as the gold standard.
In preliminary studies using a defined number of plasmids with clarithromycin and levofloxacin resistance mutations, the analytical sensitivity of our ARMS-PCR assay was 50 plasmid copies, equating to around 50 bacterium in a gastric biopsy sample. In terms of specificity, the assay was highly specific for the targeted resistance mutations. The assay was also able to reliably and efficiently detect heteroresistance of clarithromycin and levofloxacin mutations, even at a disproportional ratio of 1:1000. From the analysis of 192 samples with suspected
infections, the diagnostic sensitivity and specificity of the assay was very high for detection of clarithromycin resistance (100% and 100%), levofloxacin resistance (98.04% and 95.04%) and clarithromycin and levofloxacin double resistance (100% and 96.91%). Amongst the 74 patients diagnosed antibiotic resistance bacteria, 23 (31.1%) had clarithromycin resistance, 21 (28.4%) had levofloxacin resistance and 30 (40.5%) had double resistance. From sample receipt to results, our single tube assay could be routinely completed in under 2 h.
Our assay demonstrated high diagnostic sensitivity and specificity for detection of clarithromycin and levofloxacin resistant
. Based on proven accuracy, together with high efficiency, scalability and low cost, our assay has useful clinical utility for rapid diagnosis of clarithromycin and levofloxacin resistant
infections. Our assay results will provide patients with a clear diagnosis, enabling the treating clinician to administer the most effective antibiotic regimen to help the clear the infection. |
---|---|
ISSN: | 1757-4749 1757-4749 |