Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería

Introduction and objective. The detection of atrial fibrillation recurrences after ablation is crucial, although most of them remain undetected. The aim of this study is to evaluate the diagnostic capability for detecting atrial fibrillation recurrences of an ECG portable device, followed by a nurse...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología 2022 (86), p.39-44
Hauptverfasser: Fernández Lozano, Ignacio, Antequera Guirado, Ana, García-Izquierdo Jaén, Eusebio, Aguilera Agudo, Cristina, Vela Martín, Paula, Castro, V, de Andrés Humanes, Jesús, Segura Domínguez, Melodie, Toquero Ramos, Jorge, Jiménez Sánchez, Diego
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 44
container_issue 86
container_start_page 39
container_title Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología
container_volume
creator Fernández Lozano, Ignacio
Antequera Guirado, Ana
García-Izquierdo Jaén, Eusebio
Aguilera Agudo, Cristina
Vela Martín, Paula
Castro, V
de Andrés Humanes, Jesús
Segura Domínguez, Melodie
Toquero Ramos, Jorge
Jiménez Sánchez, Diego
description Introduction and objective. The detection of atrial fibrillation recurrences after ablation is crucial, although most of them remain undetected. The aim of this study is to evaluate the diagnostic capability for detecting atrial fibrillation recurrences of an ECG portable device, followed by a nurse, and the patient‘s adherence to the device. Methods. We conducted a prospective observational study with patients included in the CAVAC-AF study, who received an ECG portable device. Patients were instructed to perform a daily and a symptom–guided electrocardiogram (extra electrocardiogram). Review and classification of electrocardiograms was performed by a trained nurse. Results. A total of 45 patients were enrolled and had a mean follow-up of 181.5 days (±91.48). We received 7162 records: 96.31% were routine daily electrocardiograms and only 0.43% were not interpretable. The median adherence was 92.95% (IQR 26.44), being significantly superior in women (96.74% vs 82.22; p=0.038), with a superiority trend in paroxysmal vs. persistent atrial fibrillation (94.87% vs 79.53%; p=0.069) and in patients >62 years of age (94.89% vs 78.43%; p=0.068). A total of 330 atrial fibrillation records were detected (4.6%) in 14 patients (31.1%). Atrial fibrillation was recorded significantly more frequently in extra electrocardiograms compared to daily electrocardiograms (9.46% vs 4.44% p=0.0005), with a 2.24 fold risk increase of having atrial fibrillation in extra electrocardiograms. Conclusions. Obtaining records with an electrocardiogram portable device is feasible and improves the identification of atrial fibrillation recurrences by a nurse team, with an extraordinary adherence of patients. The use of these type of devices allows the patient to obtain an electrocardiogram recording during symptoms, which improves diagnostic performance. Introducción y objetivo. Tras la ablación de fibrilación auricular es fundamental detectar las recurrencias, que suelen pasar inadvertidas. El objetivo del estudio es conocer la capacidad de detección de recurrencias de fibrilación auricular mediante un dispositivo portátil de electrocardiogramas y la adherencia de los pacientes, con un seguimiento realizado por enfermería. Material y métodos. Se ha realizado un estudio prospectivo observacional sobre los pacientes del estudio CAVAC-AF a quienes se les proporcionó un dispositivo de registro electrocardiográfico portátil. A los pacientes se les instruyó para realizar un electrocardiograma di
format Article
fullrecord <record><control><sourceid>dialnet_FKZ</sourceid><recordid>TN_cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001559733</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_dialnet_unirioja_es_ART0001559733</sourcerecordid><originalsourceid>FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00015597333</originalsourceid><addsrcrecordid>eNqljkFOwzAQRbOARQXcYS5QKVEaKqRuKlTEGnVvTexJOsixo7FdqdyGA7DqEXISboIjKByAzcz8L73_56pYVM26Wa6q1f2i-Nwd0SbUPJ0dGAKLgOZAQk4zwmnW-Y7YsmWDBgxj76ZziKwRaEYi6V9aSCf5ZgNEyQNb-xfecSt80ZiEdbIoMFBOdZEgUJ944NznQXsHKVMcRh848tEDWdJRvEYx7HvBAWH0Eqf3yDZXo-U3NH728mcdyUAyfeBtcd2hDXT3s2-KzdNu__i8zKXWUVSj8IByUh5ZXbzkWNi_oqKgti_7siyrpnlY13X9T_wLETuLuQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería</title><source>Dialnet</source><creator>Fernández Lozano, Ignacio ; Antequera Guirado, Ana ; García-Izquierdo Jaén, Eusebio ; Aguilera Agudo, Cristina ; Vela Martín, Paula ; Castro, V ; de Andrés Humanes, Jesús ; Segura Domínguez, Melodie ; Toquero Ramos, Jorge ; Jiménez Sánchez, Diego</creator><creatorcontrib>Fernández Lozano, Ignacio ; Antequera Guirado, Ana ; García-Izquierdo Jaén, Eusebio ; Aguilera Agudo, Cristina ; Vela Martín, Paula ; Castro, V ; de Andrés Humanes, Jesús ; Segura Domínguez, Melodie ; Toquero Ramos, Jorge ; Jiménez Sánchez, Diego</creatorcontrib><description>Introduction and objective. The detection of atrial fibrillation recurrences after ablation is crucial, although most of them remain undetected. The aim of this study is to evaluate the diagnostic capability for detecting atrial fibrillation recurrences of an ECG portable device, followed by a nurse, and the patient‘s adherence to the device. Methods. We conducted a prospective observational study with patients included in the CAVAC-AF study, who received an ECG portable device. Patients were instructed to perform a daily and a symptom–guided electrocardiogram (extra electrocardiogram). Review and classification of electrocardiograms was performed by a trained nurse. Results. A total of 45 patients were enrolled and had a mean follow-up of 181.5 days (±91.48). We received 7162 records: 96.31% were routine daily electrocardiograms and only 0.43% were not interpretable. The median adherence was 92.95% (IQR 26.44), being significantly superior in women (96.74% vs 82.22; p=0.038), with a superiority trend in paroxysmal vs. persistent atrial fibrillation (94.87% vs 79.53%; p=0.069) and in patients &gt;62 years of age (94.89% vs 78.43%; p=0.068). A total of 330 atrial fibrillation records were detected (4.6%) in 14 patients (31.1%). Atrial fibrillation was recorded significantly more frequently in extra electrocardiograms compared to daily electrocardiograms (9.46% vs 4.44% p=0.0005), with a 2.24 fold risk increase of having atrial fibrillation in extra electrocardiograms. Conclusions. Obtaining records with an electrocardiogram portable device is feasible and improves the identification of atrial fibrillation recurrences by a nurse team, with an extraordinary adherence of patients. The use of these type of devices allows the patient to obtain an electrocardiogram recording during symptoms, which improves diagnostic performance. Introducción y objetivo. Tras la ablación de fibrilación auricular es fundamental detectar las recurrencias, que suelen pasar inadvertidas. El objetivo del estudio es conocer la capacidad de detección de recurrencias de fibrilación auricular mediante un dispositivo portátil de electrocardiogramas y la adherencia de los pacientes, con un seguimiento realizado por enfermería. Material y métodos. Se ha realizado un estudio prospectivo observacional sobre los pacientes del estudio CAVAC-AF a quienes se les proporcionó un dispositivo de registro electrocardiográfico portátil. A los pacientes se les instruyó para realizar un electrocardiograma diario, así como en caso de sintomatología (extra). La revisión y clasificación de electrocardiogramas se realizó por una enfermera entrenada. Resultados. Se incluyeron 45 pacientes con una media de seguimiento de 181,5 días (± 91,48). Se recibieron 7162 registros, 96,31% rutinarios y 99,67% interpretables. La mediana de cumplimiento fue del 92,95% (RIQ 26,44), siendo significativamente superior en mujeres (96,74% vs 82,22; p=0,038), y tendencia en pacientes con fibrilación auricular paroxística vs persistente (94,87% vs 79,53%; p=0,069) y en mayores de 62 años (94,89% vs 78,43%; p=0,068). Se identificaron 330 registros en fibrilación auricular (4,6%) en 14 pacientes (31,1%). En los electrocardiogramas extra se encontró más frecuentemente fibrilación auricular que en los rutinarios (9,46% vs 4,44% p=0,0005), con un riesgo de documentar fibrilación auricular en electrocardiograma extra 2,24 veces mayor. Conclusión. La obtención de electrocardiogramas con dispositivo portátil es factible, identificando recurrencias de fibrilación auricular por un equipo de enfermería y excelente adherencia de los pacientes. La posibilidad de realizar un electrocardiograma durante la sintomatología mejora la rentabilidad.</description><identifier>ISSN: 1575-4146</identifier><language>spa</language><subject>ablación por catéter ; arritmias cardiacas ; atrial fibrillation ; cardiac arrhythmia ; catheter ablation ; consulta remota ; electrocardiografía ; electrocardiography ; fibrilación auricular ; remote consultation</subject><ispartof>Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología, 2022 (86), p.39-44</ispartof><rights>LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,874,4022</link.rule.ids><linktorsrc>$$Uhttps://dialnet.unirioja.es/servlet/oaiart?codigo=8674200$$EView_record_in_Universidad_de_la_Rioja$$FView_record_in_$$GUniversidad_de_la_Rioja$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Fernández Lozano, Ignacio</creatorcontrib><creatorcontrib>Antequera Guirado, Ana</creatorcontrib><creatorcontrib>García-Izquierdo Jaén, Eusebio</creatorcontrib><creatorcontrib>Aguilera Agudo, Cristina</creatorcontrib><creatorcontrib>Vela Martín, Paula</creatorcontrib><creatorcontrib>Castro, V</creatorcontrib><creatorcontrib>de Andrés Humanes, Jesús</creatorcontrib><creatorcontrib>Segura Domínguez, Melodie</creatorcontrib><creatorcontrib>Toquero Ramos, Jorge</creatorcontrib><creatorcontrib>Jiménez Sánchez, Diego</creatorcontrib><title>Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería</title><title>Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología</title><description>Introduction and objective. The detection of atrial fibrillation recurrences after ablation is crucial, although most of them remain undetected. The aim of this study is to evaluate the diagnostic capability for detecting atrial fibrillation recurrences of an ECG portable device, followed by a nurse, and the patient‘s adherence to the device. Methods. We conducted a prospective observational study with patients included in the CAVAC-AF study, who received an ECG portable device. Patients were instructed to perform a daily and a symptom–guided electrocardiogram (extra electrocardiogram). Review and classification of electrocardiograms was performed by a trained nurse. Results. A total of 45 patients were enrolled and had a mean follow-up of 181.5 days (±91.48). We received 7162 records: 96.31% were routine daily electrocardiograms and only 0.43% were not interpretable. The median adherence was 92.95% (IQR 26.44), being significantly superior in women (96.74% vs 82.22; p=0.038), with a superiority trend in paroxysmal vs. persistent atrial fibrillation (94.87% vs 79.53%; p=0.069) and in patients &gt;62 years of age (94.89% vs 78.43%; p=0.068). A total of 330 atrial fibrillation records were detected (4.6%) in 14 patients (31.1%). Atrial fibrillation was recorded significantly more frequently in extra electrocardiograms compared to daily electrocardiograms (9.46% vs 4.44% p=0.0005), with a 2.24 fold risk increase of having atrial fibrillation in extra electrocardiograms. Conclusions. Obtaining records with an electrocardiogram portable device is feasible and improves the identification of atrial fibrillation recurrences by a nurse team, with an extraordinary adherence of patients. The use of these type of devices allows the patient to obtain an electrocardiogram recording during symptoms, which improves diagnostic performance. Introducción y objetivo. Tras la ablación de fibrilación auricular es fundamental detectar las recurrencias, que suelen pasar inadvertidas. El objetivo del estudio es conocer la capacidad de detección de recurrencias de fibrilación auricular mediante un dispositivo portátil de electrocardiogramas y la adherencia de los pacientes, con un seguimiento realizado por enfermería. Material y métodos. Se ha realizado un estudio prospectivo observacional sobre los pacientes del estudio CAVAC-AF a quienes se les proporcionó un dispositivo de registro electrocardiográfico portátil. A los pacientes se les instruyó para realizar un electrocardiograma diario, así como en caso de sintomatología (extra). La revisión y clasificación de electrocardiogramas se realizó por una enfermera entrenada. Resultados. Se incluyeron 45 pacientes con una media de seguimiento de 181,5 días (± 91,48). Se recibieron 7162 registros, 96,31% rutinarios y 99,67% interpretables. La mediana de cumplimiento fue del 92,95% (RIQ 26,44), siendo significativamente superior en mujeres (96,74% vs 82,22; p=0,038), y tendencia en pacientes con fibrilación auricular paroxística vs persistente (94,87% vs 79,53%; p=0,069) y en mayores de 62 años (94,89% vs 78,43%; p=0,068). Se identificaron 330 registros en fibrilación auricular (4,6%) en 14 pacientes (31,1%). En los electrocardiogramas extra se encontró más frecuentemente fibrilación auricular que en los rutinarios (9,46% vs 4,44% p=0,0005), con un riesgo de documentar fibrilación auricular en electrocardiograma extra 2,24 veces mayor. Conclusión. La obtención de electrocardiogramas con dispositivo portátil es factible, identificando recurrencias de fibrilación auricular por un equipo de enfermería y excelente adherencia de los pacientes. La posibilidad de realizar un electrocardiograma durante la sintomatología mejora la rentabilidad.</description><subject>ablación por catéter</subject><subject>arritmias cardiacas</subject><subject>atrial fibrillation</subject><subject>cardiac arrhythmia</subject><subject>catheter ablation</subject><subject>consulta remota</subject><subject>electrocardiografía</subject><subject>electrocardiography</subject><subject>fibrilación auricular</subject><subject>remote consultation</subject><issn>1575-4146</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>FKZ</sourceid><recordid>eNqljkFOwzAQRbOARQXcYS5QKVEaKqRuKlTEGnVvTexJOsixo7FdqdyGA7DqEXISboIjKByAzcz8L73_56pYVM26Wa6q1f2i-Nwd0SbUPJ0dGAKLgOZAQk4zwmnW-Y7YsmWDBgxj76ZziKwRaEYi6V9aSCf5ZgNEyQNb-xfecSt80ZiEdbIoMFBOdZEgUJ944NznQXsHKVMcRh848tEDWdJRvEYx7HvBAWH0Eqf3yDZXo-U3NH728mcdyUAyfeBtcd2hDXT3s2-KzdNu__i8zKXWUVSj8IByUh5ZXbzkWNi_oqKgti_7siyrpnlY13X9T_wLETuLuQ</recordid><startdate>2022</startdate><enddate>2022</enddate><creator>Fernández Lozano, Ignacio</creator><creator>Antequera Guirado, Ana</creator><creator>García-Izquierdo Jaén, Eusebio</creator><creator>Aguilera Agudo, Cristina</creator><creator>Vela Martín, Paula</creator><creator>Castro, V</creator><creator>de Andrés Humanes, Jesús</creator><creator>Segura Domínguez, Melodie</creator><creator>Toquero Ramos, Jorge</creator><creator>Jiménez Sánchez, Diego</creator><scope>AGMXS</scope><scope>FKZ</scope></search><sort><creationdate>2022</creationdate><title>Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería</title><author>Fernández Lozano, Ignacio ; Antequera Guirado, Ana ; García-Izquierdo Jaén, Eusebio ; Aguilera Agudo, Cristina ; Vela Martín, Paula ; Castro, V ; de Andrés Humanes, Jesús ; Segura Domínguez, Melodie ; Toquero Ramos, Jorge ; Jiménez Sánchez, Diego</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00015597333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2022</creationdate><topic>ablación por catéter</topic><topic>arritmias cardiacas</topic><topic>atrial fibrillation</topic><topic>cardiac arrhythmia</topic><topic>catheter ablation</topic><topic>consulta remota</topic><topic>electrocardiografía</topic><topic>electrocardiography</topic><topic>fibrilación auricular</topic><topic>remote consultation</topic><toplevel>online_resources</toplevel><creatorcontrib>Fernández Lozano, Ignacio</creatorcontrib><creatorcontrib>Antequera Guirado, Ana</creatorcontrib><creatorcontrib>García-Izquierdo Jaén, Eusebio</creatorcontrib><creatorcontrib>Aguilera Agudo, Cristina</creatorcontrib><creatorcontrib>Vela Martín, Paula</creatorcontrib><creatorcontrib>Castro, V</creatorcontrib><creatorcontrib>de Andrés Humanes, Jesús</creatorcontrib><creatorcontrib>Segura Domínguez, Melodie</creatorcontrib><creatorcontrib>Toquero Ramos, Jorge</creatorcontrib><creatorcontrib>Jiménez Sánchez, Diego</creatorcontrib><collection>Dialnet (Open Access Full Text)</collection><collection>Dialnet</collection><jtitle>Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Fernández Lozano, Ignacio</au><au>Antequera Guirado, Ana</au><au>García-Izquierdo Jaén, Eusebio</au><au>Aguilera Agudo, Cristina</au><au>Vela Martín, Paula</au><au>Castro, V</au><au>de Andrés Humanes, Jesús</au><au>Segura Domínguez, Melodie</au><au>Toquero Ramos, Jorge</au><au>Jiménez Sánchez, Diego</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería</atitle><jtitle>Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología</jtitle><date>2022</date><risdate>2022</risdate><issue>86</issue><spage>39</spage><epage>44</epage><pages>39-44</pages><issn>1575-4146</issn><abstract>Introduction and objective. The detection of atrial fibrillation recurrences after ablation is crucial, although most of them remain undetected. The aim of this study is to evaluate the diagnostic capability for detecting atrial fibrillation recurrences of an ECG portable device, followed by a nurse, and the patient‘s adherence to the device. Methods. We conducted a prospective observational study with patients included in the CAVAC-AF study, who received an ECG portable device. Patients were instructed to perform a daily and a symptom–guided electrocardiogram (extra electrocardiogram). Review and classification of electrocardiograms was performed by a trained nurse. Results. A total of 45 patients were enrolled and had a mean follow-up of 181.5 days (±91.48). We received 7162 records: 96.31% were routine daily electrocardiograms and only 0.43% were not interpretable. The median adherence was 92.95% (IQR 26.44), being significantly superior in women (96.74% vs 82.22; p=0.038), with a superiority trend in paroxysmal vs. persistent atrial fibrillation (94.87% vs 79.53%; p=0.069) and in patients &gt;62 years of age (94.89% vs 78.43%; p=0.068). A total of 330 atrial fibrillation records were detected (4.6%) in 14 patients (31.1%). Atrial fibrillation was recorded significantly more frequently in extra electrocardiograms compared to daily electrocardiograms (9.46% vs 4.44% p=0.0005), with a 2.24 fold risk increase of having atrial fibrillation in extra electrocardiograms. Conclusions. Obtaining records with an electrocardiogram portable device is feasible and improves the identification of atrial fibrillation recurrences by a nurse team, with an extraordinary adherence of patients. The use of these type of devices allows the patient to obtain an electrocardiogram recording during symptoms, which improves diagnostic performance. Introducción y objetivo. Tras la ablación de fibrilación auricular es fundamental detectar las recurrencias, que suelen pasar inadvertidas. El objetivo del estudio es conocer la capacidad de detección de recurrencias de fibrilación auricular mediante un dispositivo portátil de electrocardiogramas y la adherencia de los pacientes, con un seguimiento realizado por enfermería. Material y métodos. Se ha realizado un estudio prospectivo observacional sobre los pacientes del estudio CAVAC-AF a quienes se les proporcionó un dispositivo de registro electrocardiográfico portátil. A los pacientes se les instruyó para realizar un electrocardiograma diario, así como en caso de sintomatología (extra). La revisión y clasificación de electrocardiogramas se realizó por una enfermera entrenada. Resultados. Se incluyeron 45 pacientes con una media de seguimiento de 181,5 días (± 91,48). Se recibieron 7162 registros, 96,31% rutinarios y 99,67% interpretables. La mediana de cumplimiento fue del 92,95% (RIQ 26,44), siendo significativamente superior en mujeres (96,74% vs 82,22; p=0,038), y tendencia en pacientes con fibrilación auricular paroxística vs persistente (94,87% vs 79,53%; p=0,069) y en mayores de 62 años (94,89% vs 78,43%; p=0,068). Se identificaron 330 registros en fibrilación auricular (4,6%) en 14 pacientes (31,1%). En los electrocardiogramas extra se encontró más frecuentemente fibrilación auricular que en los rutinarios (9,46% vs 4,44% p=0,0005), con un riesgo de documentar fibrilación auricular en electrocardiograma extra 2,24 veces mayor. Conclusión. La obtención de electrocardiogramas con dispositivo portátil es factible, identificando recurrencias de fibrilación auricular por un equipo de enfermería y excelente adherencia de los pacientes. La posibilidad de realizar un electrocardiograma durante la sintomatología mejora la rentabilidad.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1575-4146
ispartof Enfermería en cardiología: revista científica e informativa de la Asociación Española de Enfermería en Cardiología, 2022 (86), p.39-44
issn 1575-4146
language spa
recordid cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001559733
source Dialnet
subjects ablación por catéter
arritmias cardiacas
atrial fibrillation
cardiac arrhythmia
catheter ablation
consulta remota
electrocardiografía
electrocardiography
fibrilación auricular
remote consultation
title Evaluación de la adherencia y la rentabilidad diagnóstica en detección de recurrencias tras ablación de fibrilación auricular mediante seguimiento con un dispositivo electrocardiograma portátil realizado por enfermería
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T09%3A40%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dialnet_FKZ&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluaci%C3%B3n%20de%20la%20adherencia%20y%20la%20rentabilidad%20diagn%C3%B3stica%20en%20detecci%C3%B3n%20de%20recurrencias%20tras%20ablaci%C3%B3n%20de%20fibrilaci%C3%B3n%20auricular%20mediante%20seguimiento%20con%20un%20dispositivo%20electrocardiograma%20port%C3%A1til%20realizado%20por%20enfermer%C3%ADa&rft.jtitle=Enfermer%C3%ADa%20en%20cardiolog%C3%ADa:%20revista%20cient%C3%ADfica%20e%20informativa%20de%20la%20Asociaci%C3%B3n%20Espa%C3%B1ola%20de%20Enfermer%C3%ADa%20en%20Cardiolog%C3%ADa&rft.au=Fern%C3%A1ndez%20Lozano,%20Ignacio&rft.date=2022&rft.issue=86&rft.spage=39&rft.epage=44&rft.pages=39-44&rft.issn=1575-4146&rft_id=info:doi/&rft_dat=%3Cdialnet_FKZ%3Eoai_dialnet_unirioja_es_ART0001559733%3C/dialnet_FKZ%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true