Medición de la calidad del aire mediante una red IoT: un estudio de caso

Context: The evaluation of air quality in Colombia is localized; it does not go beyond determining whether the level of the polluting gas at a specific point of the monitoring network has exceeded a threshold, according to a norm or standard, in order to trigger an alarm. It is not committed to obje...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ingeniería (Bogotá, Colombia : 1993) Colombia : 1993), 2021, Vol.26 (3), p.401-418
Hauptverfasser: Poveda Zafra, José Noé, Moreno Sánchez, Andrés Alejandro, Paz Penagos, Hernán
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 418
container_issue 3
container_start_page 401
container_title Ingeniería (Bogotá, Colombia : 1993)
container_volume 26
creator Poveda Zafra, José Noé
Moreno Sánchez, Andrés Alejandro
Paz Penagos, Hernán
description Context: The evaluation of air quality in Colombia is localized; it does not go beyond determining whether the level of the polluting gas at a specific point of the monitoring network has exceeded a threshold, according to a norm or standard, in order to trigger an alarm. It is not committed to objectives as important as the real-time identification of the dispersion dynamics of polluting gases in an area, or the prediction of the newly affected population. From this perspective, the presence of polluting gases was evaluated on the university campus of Escuela Colombiana de Ingeniería Julio Garavito, located north of the city of Bogotá, and the affected population was estimated for the month of October, 2019, using the Kriging geostatistical technique. Method: This study is part of the design and construction of an auxiliary mobile station that monitors and reports complementary information (CO and SO2 gases) to that provided by the Guaymaral meteorological station, located in the north of Bogotá. This information is transmitted through an IoT network to a server, where a database is created which stores the information on polluting gases reported by the 14 stations of the Bogotá air quality monitoring network, the information sent by the auxiliary station, and the statistical information of the population present on the university campus. Pollutant gas data and population information recorded from October 1st to 31st, 2019, are the input for data analysis using the Kriging interpolation method and predicting the affected population on said campus. Results: There is a particulate matter concentration of 29 µg/m3 of PM10 in the coliseum and 12,6 µg/m3 of PM2,5 in building G, in addition to 9,8 ppb of O3 in building I, 14,9 ppb of NO2 in that same building, 0,79 ppb of CO in building C, and 0,65 ppb of SO2 also in building C, thus allowing to infer, according to the Bogotá air quality index, a favorable air quality for a population of 2.131 people who visited the campus university during the aforementioned period. Conclusions: The correct integration of the data in the web server and their analysis, carried out in the R language, allowed determining the approximate indicators of the polluting factors around Escuela Colombiana de Ingeniería Julio Garavito. Additionally, to determine the affected population, these indicators were correlated with the information on the registered population that entered the campus during the period under study. Based on the res
format Article
fullrecord <record><control><sourceid>dialnet</sourceid><recordid>TN_cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001500838</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_dialnet_unirioja_es_ART0001500838</sourcerecordid><originalsourceid>FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00015008383</originalsourceid><addsrcrecordid>eNqli8GKwjAURYMoWJz-w_uBQtq0TB1mMwyKLtxIF-7Cs3nCk5gMSbuY7_IT_DEj6Be4upx775mIrFJ1XbRqqaYik2VVFp-NPMxFHiMfZd2oKk1VJrY7Mtzz7erAEFiEHi0bNIksIAeCSzqgGwhGhxDIwNZ3XwmA4jAa9g-vx-g_xOyENlL-zIX4Xq-6302RdOto0H-BLxj-tUfWr250HNifUVPUP_tOSlk2UraqVW_qd4XoUQ0</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Medición de la calidad del aire mediante una red IoT: un estudio de caso</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Dialnet</source><creator>Poveda Zafra, José Noé ; Moreno Sánchez, Andrés Alejandro ; Paz Penagos, Hernán</creator><creatorcontrib>Poveda Zafra, José Noé ; Moreno Sánchez, Andrés Alejandro ; Paz Penagos, Hernán</creatorcontrib><description>Context: The evaluation of air quality in Colombia is localized; it does not go beyond determining whether the level of the polluting gas at a specific point of the monitoring network has exceeded a threshold, according to a norm or standard, in order to trigger an alarm. It is not committed to objectives as important as the real-time identification of the dispersion dynamics of polluting gases in an area, or the prediction of the newly affected population. From this perspective, the presence of polluting gases was evaluated on the university campus of Escuela Colombiana de Ingeniería Julio Garavito, located north of the city of Bogotá, and the affected population was estimated for the month of October, 2019, using the Kriging geostatistical technique. Method: This study is part of the design and construction of an auxiliary mobile station that monitors and reports complementary information (CO and SO2 gases) to that provided by the Guaymaral meteorological station, located in the north of Bogotá. This information is transmitted through an IoT network to a server, where a database is created which stores the information on polluting gases reported by the 14 stations of the Bogotá air quality monitoring network, the information sent by the auxiliary station, and the statistical information of the population present on the university campus. Pollutant gas data and population information recorded from October 1st to 31st, 2019, are the input for data analysis using the Kriging interpolation method and predicting the affected population on said campus. Results: There is a particulate matter concentration of 29 µg/m3 of PM10 in the coliseum and 12,6 µg/m3 of PM2,5 in building G, in addition to 9,8 ppb of O3 in building I, 14,9 ppb of NO2 in that same building, 0,79 ppb of CO in building C, and 0,65 ppb of SO2 also in building C, thus allowing to infer, according to the Bogotá air quality index, a favorable air quality for a population of 2.131 people who visited the campus university during the aforementioned period. Conclusions: The correct integration of the data in the web server and their analysis, carried out in the R language, allowed determining the approximate indicators of the polluting factors around Escuela Colombiana de Ingeniería Julio Garavito. Additionally, to determine the affected population, these indicators were correlated with the information on the registered population that entered the campus during the period under study. Based on the results obtained, it was concluded that the air quality on the campus of Escuela Colombiana de Ingeniería Julio Garavito is favorable, and that 2.131 people benefited daily from these conditions. Contexto: La evaluación de la calidad del aire en Colombia es localizada; no va más allá de determinar si el nivel del gas contaminante en un punto específico de la red de monitoreo ha excedido un umbral, de acuerdo con una norma o estándar, con el fin de generar una alarma. No se compromete con objetivos tan importantes como identificar en tiempo real la dinámica de dispersión de los gases contaminantes en una zona, ni la predicción de la nueva población afectada. Desde esta perspectiva, se evaluó la presencia de los gases contaminantes en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito, ubicada al norte de la ciudad de Bogotá, y se estimó la población afectada para el mes de octubre de 2019 utilizando la técnica geoestadística de Kriging. Método: Este estudio forma parte del diseño y construcción de una estación móvil auxiliar que monitorea y reporta información complementaria (gases CO y SO2) a la que brinda la estación meteorológica de Guaymaral, ubicada en el norte de Bogotá. Esta información es transmitida a través de una red IoT hacia un servidor, donde se crea una base de datos que almacena la información de los gases contaminantes reportada por las 14 estaciones de la red de monitoreo de calidad del aire de Bogotá, la información enviada por la estación auxiliar y la información estadística de la población presente en el campus universitario. Los datos de los gases contaminantes y la información de la población registrada desde el 1 al 31 de octubre de 2019 son el insumo para el análisis de datos mediante el método de interpolación de Kriging y la predicción de la población afectada en dicho campus. Resultados: Se encuentra una concentración de material particulado de 29 µg/m3 de PM10 en el coliseo y 12,6 µg/m3 de PM2,5 en el edificio G. Además de 9,8 ppb de O3 en el edificio I, 14,9 ppb de NO2 en ese mismo edificio, 0,79 ppb de CO en el edificio C y 0,65 ppb de SO2 también en el edificio C, permitiendo inferir, según el índice de calidad del aire de Bogotá, una calidad del aire favorable para una población de 2.131 personas que visitaron el campus universitario durante el período mencionado. Conclusiones: La correcta integración de los datos en el servidor web y el análisis de estos, realizado en lenguaje R, permitieron determinar los indicadores aproximados de los factores contaminantes en el área de la Escuela Colombiana de Ingeniería Julio Garavito. Adicionalmente, para determinar la población afectada, estos indicadores se correlacionaron con la información de la población registrada que ingresó al campus durante el periodo de estudio. Con base en los resultados obtenidos, se pudo concluir que la calidad del aire en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito es favorable y 2.131 personas se beneficiaron diariamente de estas condiciones.</description><identifier>ISSN: 0121-750X</identifier><identifier>ISSN: 2344-8393</identifier><identifier>EISSN: 2344-8393</identifier><language>spa</language><subject>air quality ; area ; calidad del aire ; factores contaminantes ; Kriging method ; modelación ; modeling ; método de Kriging ; población ; polluting factors ; population ; área</subject><ispartof>Ingeniería (Bogotá, Colombia : 1993), 2021, Vol.26 (3), p.401-418</ispartof><rights>LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,874,4024</link.rule.ids></links><search><creatorcontrib>Poveda Zafra, José Noé</creatorcontrib><creatorcontrib>Moreno Sánchez, Andrés Alejandro</creatorcontrib><creatorcontrib>Paz Penagos, Hernán</creatorcontrib><title>Medición de la calidad del aire mediante una red IoT: un estudio de caso</title><title>Ingeniería (Bogotá, Colombia : 1993)</title><description>Context: The evaluation of air quality in Colombia is localized; it does not go beyond determining whether the level of the polluting gas at a specific point of the monitoring network has exceeded a threshold, according to a norm or standard, in order to trigger an alarm. It is not committed to objectives as important as the real-time identification of the dispersion dynamics of polluting gases in an area, or the prediction of the newly affected population. From this perspective, the presence of polluting gases was evaluated on the university campus of Escuela Colombiana de Ingeniería Julio Garavito, located north of the city of Bogotá, and the affected population was estimated for the month of October, 2019, using the Kriging geostatistical technique. Method: This study is part of the design and construction of an auxiliary mobile station that monitors and reports complementary information (CO and SO2 gases) to that provided by the Guaymaral meteorological station, located in the north of Bogotá. This information is transmitted through an IoT network to a server, where a database is created which stores the information on polluting gases reported by the 14 stations of the Bogotá air quality monitoring network, the information sent by the auxiliary station, and the statistical information of the population present on the university campus. Pollutant gas data and population information recorded from October 1st to 31st, 2019, are the input for data analysis using the Kriging interpolation method and predicting the affected population on said campus. Results: There is a particulate matter concentration of 29 µg/m3 of PM10 in the coliseum and 12,6 µg/m3 of PM2,5 in building G, in addition to 9,8 ppb of O3 in building I, 14,9 ppb of NO2 in that same building, 0,79 ppb of CO in building C, and 0,65 ppb of SO2 also in building C, thus allowing to infer, according to the Bogotá air quality index, a favorable air quality for a population of 2.131 people who visited the campus university during the aforementioned period. Conclusions: The correct integration of the data in the web server and their analysis, carried out in the R language, allowed determining the approximate indicators of the polluting factors around Escuela Colombiana de Ingeniería Julio Garavito. Additionally, to determine the affected population, these indicators were correlated with the information on the registered population that entered the campus during the period under study. Based on the results obtained, it was concluded that the air quality on the campus of Escuela Colombiana de Ingeniería Julio Garavito is favorable, and that 2.131 people benefited daily from these conditions. Contexto: La evaluación de la calidad del aire en Colombia es localizada; no va más allá de determinar si el nivel del gas contaminante en un punto específico de la red de monitoreo ha excedido un umbral, de acuerdo con una norma o estándar, con el fin de generar una alarma. No se compromete con objetivos tan importantes como identificar en tiempo real la dinámica de dispersión de los gases contaminantes en una zona, ni la predicción de la nueva población afectada. Desde esta perspectiva, se evaluó la presencia de los gases contaminantes en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito, ubicada al norte de la ciudad de Bogotá, y se estimó la población afectada para el mes de octubre de 2019 utilizando la técnica geoestadística de Kriging. Método: Este estudio forma parte del diseño y construcción de una estación móvil auxiliar que monitorea y reporta información complementaria (gases CO y SO2) a la que brinda la estación meteorológica de Guaymaral, ubicada en el norte de Bogotá. Esta información es transmitida a través de una red IoT hacia un servidor, donde se crea una base de datos que almacena la información de los gases contaminantes reportada por las 14 estaciones de la red de monitoreo de calidad del aire de Bogotá, la información enviada por la estación auxiliar y la información estadística de la población presente en el campus universitario. Los datos de los gases contaminantes y la información de la población registrada desde el 1 al 31 de octubre de 2019 son el insumo para el análisis de datos mediante el método de interpolación de Kriging y la predicción de la población afectada en dicho campus. Resultados: Se encuentra una concentración de material particulado de 29 µg/m3 de PM10 en el coliseo y 12,6 µg/m3 de PM2,5 en el edificio G. Además de 9,8 ppb de O3 en el edificio I, 14,9 ppb de NO2 en ese mismo edificio, 0,79 ppb de CO en el edificio C y 0,65 ppb de SO2 también en el edificio C, permitiendo inferir, según el índice de calidad del aire de Bogotá, una calidad del aire favorable para una población de 2.131 personas que visitaron el campus universitario durante el período mencionado. Conclusiones: La correcta integración de los datos en el servidor web y el análisis de estos, realizado en lenguaje R, permitieron determinar los indicadores aproximados de los factores contaminantes en el área de la Escuela Colombiana de Ingeniería Julio Garavito. Adicionalmente, para determinar la población afectada, estos indicadores se correlacionaron con la información de la población registrada que ingresó al campus durante el periodo de estudio. Con base en los resultados obtenidos, se pudo concluir que la calidad del aire en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito es favorable y 2.131 personas se beneficiaron diariamente de estas condiciones.</description><subject>air quality</subject><subject>area</subject><subject>calidad del aire</subject><subject>factores contaminantes</subject><subject>Kriging method</subject><subject>modelación</subject><subject>modeling</subject><subject>método de Kriging</subject><subject>población</subject><subject>polluting factors</subject><subject>population</subject><subject>área</subject><issn>0121-750X</issn><issn>2344-8393</issn><issn>2344-8393</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>FKZ</sourceid><recordid>eNqli8GKwjAURYMoWJz-w_uBQtq0TB1mMwyKLtxIF-7Cs3nCk5gMSbuY7_IT_DEj6Be4upx775mIrFJ1XbRqqaYik2VVFp-NPMxFHiMfZd2oKk1VJrY7Mtzz7erAEFiEHi0bNIksIAeCSzqgGwhGhxDIwNZ3XwmA4jAa9g-vx-g_xOyENlL-zIX4Xq-6302RdOto0H-BLxj-tUfWr250HNifUVPUP_tOSlk2UraqVW_qd4XoUQ0</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Poveda Zafra, José Noé</creator><creator>Moreno Sánchez, Andrés Alejandro</creator><creator>Paz Penagos, Hernán</creator><scope>AGMXS</scope><scope>FKZ</scope></search><sort><creationdate>2021</creationdate><title>Medición de la calidad del aire mediante una red IoT: un estudio de caso</title><author>Poveda Zafra, José Noé ; Moreno Sánchez, Andrés Alejandro ; Paz Penagos, Hernán</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00015008383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2021</creationdate><topic>air quality</topic><topic>area</topic><topic>calidad del aire</topic><topic>factores contaminantes</topic><topic>Kriging method</topic><topic>modelación</topic><topic>modeling</topic><topic>método de Kriging</topic><topic>población</topic><topic>polluting factors</topic><topic>population</topic><topic>área</topic><toplevel>online_resources</toplevel><creatorcontrib>Poveda Zafra, José Noé</creatorcontrib><creatorcontrib>Moreno Sánchez, Andrés Alejandro</creatorcontrib><creatorcontrib>Paz Penagos, Hernán</creatorcontrib><collection>Dialnet (Open Access Full Text)</collection><collection>Dialnet</collection><jtitle>Ingeniería (Bogotá, Colombia : 1993)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Poveda Zafra, José Noé</au><au>Moreno Sánchez, Andrés Alejandro</au><au>Paz Penagos, Hernán</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Medición de la calidad del aire mediante una red IoT: un estudio de caso</atitle><jtitle>Ingeniería (Bogotá, Colombia : 1993)</jtitle><date>2021</date><risdate>2021</risdate><volume>26</volume><issue>3</issue><spage>401</spage><epage>418</epage><pages>401-418</pages><issn>0121-750X</issn><issn>2344-8393</issn><eissn>2344-8393</eissn><abstract>Context: The evaluation of air quality in Colombia is localized; it does not go beyond determining whether the level of the polluting gas at a specific point of the monitoring network has exceeded a threshold, according to a norm or standard, in order to trigger an alarm. It is not committed to objectives as important as the real-time identification of the dispersion dynamics of polluting gases in an area, or the prediction of the newly affected population. From this perspective, the presence of polluting gases was evaluated on the university campus of Escuela Colombiana de Ingeniería Julio Garavito, located north of the city of Bogotá, and the affected population was estimated for the month of October, 2019, using the Kriging geostatistical technique. Method: This study is part of the design and construction of an auxiliary mobile station that monitors and reports complementary information (CO and SO2 gases) to that provided by the Guaymaral meteorological station, located in the north of Bogotá. This information is transmitted through an IoT network to a server, where a database is created which stores the information on polluting gases reported by the 14 stations of the Bogotá air quality monitoring network, the information sent by the auxiliary station, and the statistical information of the population present on the university campus. Pollutant gas data and population information recorded from October 1st to 31st, 2019, are the input for data analysis using the Kriging interpolation method and predicting the affected population on said campus. Results: There is a particulate matter concentration of 29 µg/m3 of PM10 in the coliseum and 12,6 µg/m3 of PM2,5 in building G, in addition to 9,8 ppb of O3 in building I, 14,9 ppb of NO2 in that same building, 0,79 ppb of CO in building C, and 0,65 ppb of SO2 also in building C, thus allowing to infer, according to the Bogotá air quality index, a favorable air quality for a population of 2.131 people who visited the campus university during the aforementioned period. Conclusions: The correct integration of the data in the web server and their analysis, carried out in the R language, allowed determining the approximate indicators of the polluting factors around Escuela Colombiana de Ingeniería Julio Garavito. Additionally, to determine the affected population, these indicators were correlated with the information on the registered population that entered the campus during the period under study. Based on the results obtained, it was concluded that the air quality on the campus of Escuela Colombiana de Ingeniería Julio Garavito is favorable, and that 2.131 people benefited daily from these conditions. Contexto: La evaluación de la calidad del aire en Colombia es localizada; no va más allá de determinar si el nivel del gas contaminante en un punto específico de la red de monitoreo ha excedido un umbral, de acuerdo con una norma o estándar, con el fin de generar una alarma. No se compromete con objetivos tan importantes como identificar en tiempo real la dinámica de dispersión de los gases contaminantes en una zona, ni la predicción de la nueva población afectada. Desde esta perspectiva, se evaluó la presencia de los gases contaminantes en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito, ubicada al norte de la ciudad de Bogotá, y se estimó la población afectada para el mes de octubre de 2019 utilizando la técnica geoestadística de Kriging. Método: Este estudio forma parte del diseño y construcción de una estación móvil auxiliar que monitorea y reporta información complementaria (gases CO y SO2) a la que brinda la estación meteorológica de Guaymaral, ubicada en el norte de Bogotá. Esta información es transmitida a través de una red IoT hacia un servidor, donde se crea una base de datos que almacena la información de los gases contaminantes reportada por las 14 estaciones de la red de monitoreo de calidad del aire de Bogotá, la información enviada por la estación auxiliar y la información estadística de la población presente en el campus universitario. Los datos de los gases contaminantes y la información de la población registrada desde el 1 al 31 de octubre de 2019 son el insumo para el análisis de datos mediante el método de interpolación de Kriging y la predicción de la población afectada en dicho campus. Resultados: Se encuentra una concentración de material particulado de 29 µg/m3 de PM10 en el coliseo y 12,6 µg/m3 de PM2,5 en el edificio G. Además de 9,8 ppb de O3 en el edificio I, 14,9 ppb de NO2 en ese mismo edificio, 0,79 ppb de CO en el edificio C y 0,65 ppb de SO2 también en el edificio C, permitiendo inferir, según el índice de calidad del aire de Bogotá, una calidad del aire favorable para una población de 2.131 personas que visitaron el campus universitario durante el período mencionado. Conclusiones: La correcta integración de los datos en el servidor web y el análisis de estos, realizado en lenguaje R, permitieron determinar los indicadores aproximados de los factores contaminantes en el área de la Escuela Colombiana de Ingeniería Julio Garavito. Adicionalmente, para determinar la población afectada, estos indicadores se correlacionaron con la información de la población registrada que ingresó al campus durante el periodo de estudio. Con base en los resultados obtenidos, se pudo concluir que la calidad del aire en el campus universitario de la Escuela Colombiana de Ingeniería Julio Garavito es favorable y 2.131 personas se beneficiaron diariamente de estas condiciones.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0121-750X
ispartof Ingeniería (Bogotá, Colombia : 1993), 2021, Vol.26 (3), p.401-418
issn 0121-750X
2344-8393
2344-8393
language spa
recordid cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001500838
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Dialnet
subjects air quality
area
calidad del aire
factores contaminantes
Kriging method
modelación
modeling
método de Kriging
población
polluting factors
population
área
title Medición de la calidad del aire mediante una red IoT: un estudio de caso
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T07%3A36%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dialnet&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Medici%C3%B3n%20de%20la%20calidad%20del%20aire%20mediante%20una%20red%20IoT:%20un%20estudio%20de%20caso&rft.jtitle=Ingenier%C3%ADa%20(Bogot%C3%A1,%20Colombia%20:%201993)&rft.au=Poveda%20Zafra,%20Jos%C3%A9%20No%C3%A9&rft.date=2021&rft.volume=26&rft.issue=3&rft.spage=401&rft.epage=418&rft.pages=401-418&rft.issn=0121-750X&rft.eissn=2344-8393&rft_id=info:doi/&rft_dat=%3Cdialnet%3Eoai_dialnet_unirioja_es_ART0001500838%3C/dialnet%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true