Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle
The thermodynamic analysis of the geothermal power plants with dry vapor, flash steam and hybrid cycles in function to the geothermal resource conditions and the pressure of the first flash chamber was made, considering the steam quality of the last stage of expansion as operating limit constraint;...
Gespeichert in:
Veröffentlicht in: | Dyna (Medellín, Colombia) Colombia), 2017, Vol.84 (203), p.273-282 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 282 |
---|---|
container_issue | 203 |
container_start_page | 273 |
container_title | Dyna (Medellín, Colombia) |
container_volume | 84 |
creator | Salazar Pereyra, Martín Lugo Méndez, Helen D Bonilla Blancas, Angélica E Mora Ortega, Agustín Lugo Leyte, Raúl |
description | The thermodynamic analysis of the geothermal power plants with dry vapor, flash steam and hybrid cycles in function to the geothermal resource conditions and the pressure of the first flash chamber was made, considering the steam quality of the last stage of expansion as operating limit constraint; obtaining the specific work curves of the steam turbines and the temperature profiles of the binary cycle. For saturated steam configurations, the arrangement with three flash cameras presents the highest thermal and exergy efficiency, and steam turbines specific work, for example at a temperature of 200 ° C, the maximum work generated is 80.11 kJ / kg with a pressure of the first flash chamber of 6.0 bar, thermal and exergetic efficiency of 10.7% and 44.0% respectively, this is mainly due to the increase of steam enthalpy and exergy.
En este trabajo sepresenta el análisis termodinámico de las centrales geotérmicas con configuraciones de vapor seco, cámaras flash y ciclos híbridos en función de las condiciones del recurso geotérmico y la presión de la primera cámara flash, considerando la calidad del vapor de la última etapa de expansión como restricción límite de operación; se obtienen las curvas de trabajo de las turbinas de vapor y los perfiles de temperatura del ciclo binario. Para las configuraciones con vapor húmedo, el arreglo con tres cámaras flash presenta la mayor eficiencia térmica, exergética y de trabajo de las turbinas de vapor, por ejemplo para una temperatura de 200°C, el máximo trabajo generado es de 80.11 kJ/kg con una presión de la primera cámara flash de 6.0 bar, la eficiencia térmica y exergética de 10.7% y 44.0% respectivamente, esto se debe principalmente al aprovechamiento del aumento de la entalpía y exergía del vapor. |
format | Article |
fullrecord | <record><control><sourceid>dialnet</sourceid><recordid>TN_cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001262348</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_dialnet_unirioja_es_ART0001262348</sourcerecordid><originalsourceid>FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00012623483</originalsourceid><addsrcrecordid>eNqljssKwjAQRbNQ8PkP8wEWUlsfiBvxgUvR7sPYTm0kbcqkIvl7W9AvcHU4Fw7cnhhKGc6DVbSIBmLk3FPKeBHK9VAkF2QsqWGdAlZovNMObA5NQfAg24JLNFDbN_EGDuyDW0NYziA36ApwnbRhBoW_s84g9amhiejnaBxNvxyL7emY7M9BptFU1KiadYnslUWtftur0qztExU5tbsmsnu8nEfxOvoz_wDeFlLS</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle</title><source>DOAJ Directory of Open Access Journals</source><source>Dialnet</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Salazar Pereyra, Martín ; Lugo Méndez, Helen D ; Bonilla Blancas, Angélica E ; Mora Ortega, Agustín ; Lugo Leyte, Raúl</creator><creatorcontrib>Salazar Pereyra, Martín ; Lugo Méndez, Helen D ; Bonilla Blancas, Angélica E ; Mora Ortega, Agustín ; Lugo Leyte, Raúl</creatorcontrib><description>The thermodynamic analysis of the geothermal power plants with dry vapor, flash steam and hybrid cycles in function to the geothermal resource conditions and the pressure of the first flash chamber was made, considering the steam quality of the last stage of expansion as operating limit constraint; obtaining the specific work curves of the steam turbines and the temperature profiles of the binary cycle. For saturated steam configurations, the arrangement with three flash cameras presents the highest thermal and exergy efficiency, and steam turbines specific work, for example at a temperature of 200 ° C, the maximum work generated is 80.11 kJ / kg with a pressure of the first flash chamber of 6.0 bar, thermal and exergetic efficiency of 10.7% and 44.0% respectively, this is mainly due to the increase of steam enthalpy and exergy.
En este trabajo sepresenta el análisis termodinámico de las centrales geotérmicas con configuraciones de vapor seco, cámaras flash y ciclos híbridos en función de las condiciones del recurso geotérmico y la presión de la primera cámara flash, considerando la calidad del vapor de la última etapa de expansión como restricción límite de operación; se obtienen las curvas de trabajo de las turbinas de vapor y los perfiles de temperatura del ciclo binario. Para las configuraciones con vapor húmedo, el arreglo con tres cámaras flash presenta la mayor eficiencia térmica, exergética y de trabajo de las turbinas de vapor, por ejemplo para una temperatura de 200°C, el máximo trabajo generado es de 80.11 kJ/kg con una presión de la primera cámara flash de 6.0 bar, la eficiencia térmica y exergética de 10.7% y 44.0% respectivamente, esto se debe principalmente al aprovechamiento del aumento de la entalpía y exergía del vapor.</description><identifier>ISSN: 0012-7353</identifier><language>eng</language><subject>análisis termodinámico ; flash geothermal ; Geotermoeléctrica ; Steam turbines ; thermodynamic analysis ; turbinas de vapor</subject><ispartof>Dyna (Medellín, Colombia), 2017, Vol.84 (203), p.273-282</ispartof><rights>LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,874,4024</link.rule.ids></links><search><creatorcontrib>Salazar Pereyra, Martín</creatorcontrib><creatorcontrib>Lugo Méndez, Helen D</creatorcontrib><creatorcontrib>Bonilla Blancas, Angélica E</creatorcontrib><creatorcontrib>Mora Ortega, Agustín</creatorcontrib><creatorcontrib>Lugo Leyte, Raúl</creatorcontrib><title>Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle</title><title>Dyna (Medellín, Colombia)</title><description>The thermodynamic analysis of the geothermal power plants with dry vapor, flash steam and hybrid cycles in function to the geothermal resource conditions and the pressure of the first flash chamber was made, considering the steam quality of the last stage of expansion as operating limit constraint; obtaining the specific work curves of the steam turbines and the temperature profiles of the binary cycle. For saturated steam configurations, the arrangement with three flash cameras presents the highest thermal and exergy efficiency, and steam turbines specific work, for example at a temperature of 200 ° C, the maximum work generated is 80.11 kJ / kg with a pressure of the first flash chamber of 6.0 bar, thermal and exergetic efficiency of 10.7% and 44.0% respectively, this is mainly due to the increase of steam enthalpy and exergy.
En este trabajo sepresenta el análisis termodinámico de las centrales geotérmicas con configuraciones de vapor seco, cámaras flash y ciclos híbridos en función de las condiciones del recurso geotérmico y la presión de la primera cámara flash, considerando la calidad del vapor de la última etapa de expansión como restricción límite de operación; se obtienen las curvas de trabajo de las turbinas de vapor y los perfiles de temperatura del ciclo binario. Para las configuraciones con vapor húmedo, el arreglo con tres cámaras flash presenta la mayor eficiencia térmica, exergética y de trabajo de las turbinas de vapor, por ejemplo para una temperatura de 200°C, el máximo trabajo generado es de 80.11 kJ/kg con una presión de la primera cámara flash de 6.0 bar, la eficiencia térmica y exergética de 10.7% y 44.0% respectivamente, esto se debe principalmente al aprovechamiento del aumento de la entalpía y exergía del vapor.</description><subject>análisis termodinámico</subject><subject>flash geothermal</subject><subject>Geotermoeléctrica</subject><subject>Steam turbines</subject><subject>thermodynamic analysis</subject><subject>turbinas de vapor</subject><issn>0012-7353</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>FKZ</sourceid><recordid>eNqljssKwjAQRbNQ8PkP8wEWUlsfiBvxgUvR7sPYTm0kbcqkIvl7W9AvcHU4Fw7cnhhKGc6DVbSIBmLk3FPKeBHK9VAkF2QsqWGdAlZovNMObA5NQfAg24JLNFDbN_EGDuyDW0NYziA36ApwnbRhBoW_s84g9amhiejnaBxNvxyL7emY7M9BptFU1KiadYnslUWtftur0qztExU5tbsmsnu8nEfxOvoz_wDeFlLS</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Salazar Pereyra, Martín</creator><creator>Lugo Méndez, Helen D</creator><creator>Bonilla Blancas, Angélica E</creator><creator>Mora Ortega, Agustín</creator><creator>Lugo Leyte, Raúl</creator><scope>AGMXS</scope><scope>FKZ</scope></search><sort><creationdate>2017</creationdate><title>Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle</title><author>Salazar Pereyra, Martín ; Lugo Méndez, Helen D ; Bonilla Blancas, Angélica E ; Mora Ortega, Agustín ; Lugo Leyte, Raúl</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00012623483</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>análisis termodinámico</topic><topic>flash geothermal</topic><topic>Geotermoeléctrica</topic><topic>Steam turbines</topic><topic>thermodynamic analysis</topic><topic>turbinas de vapor</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Salazar Pereyra, Martín</creatorcontrib><creatorcontrib>Lugo Méndez, Helen D</creatorcontrib><creatorcontrib>Bonilla Blancas, Angélica E</creatorcontrib><creatorcontrib>Mora Ortega, Agustín</creatorcontrib><creatorcontrib>Lugo Leyte, Raúl</creatorcontrib><collection>Dialnet (Open Access Full Text)</collection><collection>Dialnet</collection><jtitle>Dyna (Medellín, Colombia)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Salazar Pereyra, Martín</au><au>Lugo Méndez, Helen D</au><au>Bonilla Blancas, Angélica E</au><au>Mora Ortega, Agustín</au><au>Lugo Leyte, Raúl</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle</atitle><jtitle>Dyna (Medellín, Colombia)</jtitle><date>2017</date><risdate>2017</risdate><volume>84</volume><issue>203</issue><spage>273</spage><epage>282</epage><pages>273-282</pages><issn>0012-7353</issn><abstract>The thermodynamic analysis of the geothermal power plants with dry vapor, flash steam and hybrid cycles in function to the geothermal resource conditions and the pressure of the first flash chamber was made, considering the steam quality of the last stage of expansion as operating limit constraint; obtaining the specific work curves of the steam turbines and the temperature profiles of the binary cycle. For saturated steam configurations, the arrangement with three flash cameras presents the highest thermal and exergy efficiency, and steam turbines specific work, for example at a temperature of 200 ° C, the maximum work generated is 80.11 kJ / kg with a pressure of the first flash chamber of 6.0 bar, thermal and exergetic efficiency of 10.7% and 44.0% respectively, this is mainly due to the increase of steam enthalpy and exergy.
En este trabajo sepresenta el análisis termodinámico de las centrales geotérmicas con configuraciones de vapor seco, cámaras flash y ciclos híbridos en función de las condiciones del recurso geotérmico y la presión de la primera cámara flash, considerando la calidad del vapor de la última etapa de expansión como restricción límite de operación; se obtienen las curvas de trabajo de las turbinas de vapor y los perfiles de temperatura del ciclo binario. Para las configuraciones con vapor húmedo, el arreglo con tres cámaras flash presenta la mayor eficiencia térmica, exergética y de trabajo de las turbinas de vapor, por ejemplo para una temperatura de 200°C, el máximo trabajo generado es de 80.11 kJ/kg con una presión de la primera cámara flash de 6.0 bar, la eficiencia térmica y exergética de 10.7% y 44.0% respectivamente, esto se debe principalmente al aprovechamiento del aumento de la entalpía y exergía del vapor.</abstract><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0012-7353 |
ispartof | Dyna (Medellín, Colombia), 2017, Vol.84 (203), p.273-282 |
issn | 0012-7353 |
language | eng |
recordid | cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0001262348 |
source | DOAJ Directory of Open Access Journals; Dialnet; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
subjects | análisis termodinámico flash geothermal Geotermoeléctrica Steam turbines thermodynamic analysis turbinas de vapor |
title | Parametric analysis of the geothermal power: Dry-Steam, flash steam and hybrid cycle |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T04%3A57%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dialnet&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Parametric%20analysis%20of%20the%20geothermal%20power:%20Dry-Steam,%20flash%20steam%20and%20hybrid%20cycle&rft.jtitle=Dyna%20(Medelli%CC%81n,%20Colombia)&rft.au=Salazar%20Pereyra,%20Mart%C3%ADn&rft.date=2017&rft.volume=84&rft.issue=203&rft.spage=273&rft.epage=282&rft.pages=273-282&rft.issn=0012-7353&rft_id=info:doi/&rft_dat=%3Cdialnet%3Eoai_dialnet_unirioja_es_ART0001262348%3C/dialnet%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |