Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales

Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista internacional de ciencias del deporte 2012, Vol.8 (30), p.334-356
Hauptverfasser: Blas Foix, Xavier de, López del Amo, José Luis, Guerra Bálic, Myriam, Padullés Riu, Josep María
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 356
container_issue 30
container_start_page 334
container_title Revista internacional de ciencias del deporte
container_volume 8
creator Blas Foix, Xavier de
López del Amo, José Luis
Guerra Bálic, Myriam
Padullés Riu, Josep María
description Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages. La medición de la altura del salto vertical es un indicador de la fuerza y potencia del tren inferior. Los instrumentos electrónicos disponibles para medir este salto son cajas negras que no permiten la verificación ni la adaptación por parte de terceros. Proponemos la creación de un sistema de medición llamado Chronojump-Boscosystem, que consiste en un hardware abierto y un software libre. Métodos: Se ha creado un microcontrolador y se ha validado usando un generador de ondas cuadradas y un osciloscopio. Se han desarrollado dos tipos de plataformas usando materiales distintos. Las plataformas se han validado determinando su sensibilidad en distintos puntos por medio de una célula de carga, y por comparación con la plataforma de contactos del sistema Ergojump-Boscosystem en una muestra de 8 sujetos, realizando saltos sub-máximos con un pie en cada plataforma. Se ha usado una metodología ágil para el desarrollo y validación del software. Resultados: Todas las partes que componen el sistema se han licenciado como software libre o hardware abierto. El margen de error del microcontrolador es de 0,1%. La validez de la plataforma de fibra de vidrio es de 0,95 (ICC). El software de gestión tiene cerca de 113 mil líneas de código y está disponible en 7 idiomas.
format Article
fullrecord <record><control><sourceid>dialnet</sourceid><recordid>TN_cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0000560111</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_dialnet_unirioja_es_ART0000560111</sourcerecordid><originalsourceid>FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00005601113</originalsourceid><addsrcrecordid>eNqljEtqw0AQRIfgQOwkd-gLCDQIyyJkkwibrIP3Q1vqkBbzEd0jg87lI-Ri8cIJ3rs2Va-g6s4sbdOsi8pWm8VVfjAr1aEs66bZ1EsTWyHs-OcUYYYjeu4v1BO035JiGqYwFu9Ju6SzZgovMEXgqFmmQDEn8HwQghEFwSME6vn_QdHnpHAkydyhJ30y91_olZ4v_mhed9t9-1H0jD5SdqNwQJldQnZ_3RRZOA3oSN3b5748a12X1trqxvkv5ethTw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales</title><source>Dialnet</source><source>DOAJ Directory of Open Access Journals</source><source>EZB Electronic Journals Library</source><creator>Blas Foix, Xavier de ; López del Amo, José Luis ; Guerra Bálic, Myriam ; Padullés Riu, Josep María</creator><creatorcontrib>Blas Foix, Xavier de ; López del Amo, José Luis ; Guerra Bálic, Myriam ; Padullés Riu, Josep María</creatorcontrib><description>Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages. La medición de la altura del salto vertical es un indicador de la fuerza y potencia del tren inferior. Los instrumentos electrónicos disponibles para medir este salto son cajas negras que no permiten la verificación ni la adaptación por parte de terceros. Proponemos la creación de un sistema de medición llamado Chronojump-Boscosystem, que consiste en un hardware abierto y un software libre. Métodos: Se ha creado un microcontrolador y se ha validado usando un generador de ondas cuadradas y un osciloscopio. Se han desarrollado dos tipos de plataformas usando materiales distintos. Las plataformas se han validado determinando su sensibilidad en distintos puntos por medio de una célula de carga, y por comparación con la plataforma de contactos del sistema Ergojump-Boscosystem en una muestra de 8 sujetos, realizando saltos sub-máximos con un pie en cada plataforma. Se ha usado una metodología ágil para el desarrollo y validación del software. Resultados: Todas las partes que componen el sistema se han licenciado como software libre o hardware abierto. El margen de error del microcontrolador es de 0,1%. La validez de la plataforma de fibra de vidrio es de 0,95 (ICC). El software de gestión tiene cerca de 113 mil líneas de código y está disponible en 7 idiomas.</description><identifier>ISSN: 1885-3137</identifier><identifier>EISSN: 1885-3137</identifier><language>eng</language><publisher>Ramón Cantó Alcaraz</publisher><subject>biomechanics ; biomecánica ; boscosystem ; chronojump ; free software ; hardware abierto ; jump ; open hardware ; saltos ; software libre</subject><ispartof>Revista internacional de ciencias del deporte, 2012, Vol.8 (30), p.334-356</ispartof><rights>LICENCIA DE USO: Los documentos a texto completo incluidos en Dialnet son de acceso libre y propiedad de sus autores y/o editores. Por tanto, cualquier acto de reproducción, distribución, comunicación pública y/o transformación total o parcial requiere el consentimiento expreso y escrito de aquéllos. Cualquier enlace al texto completo de estos documentos deberá hacerse a través de la URL oficial de éstos en Dialnet. Más información: https://dialnet.unirioja.es/info/derechosOAI | INTELLECTUAL PROPERTY RIGHTS STATEMENT: Full text documents hosted by Dialnet are protected by copyright and/or related rights. This digital object is accessible without charge, but its use is subject to the licensing conditions set by its authors or editors. Unless expressly stated otherwise in the licensing conditions, you are free to linking, browsing, printing and making a copy for your own personal purposes. All other acts of reproduction and communication to the public are subject to the licensing conditions expressed by editors and authors and require consent from them. Any link to this document should be made using its official URL in Dialnet. More info: https://dialnet.unirioja.es/info/derechosOAI</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,870,4010</link.rule.ids></links><search><creatorcontrib>Blas Foix, Xavier de</creatorcontrib><creatorcontrib>López del Amo, José Luis</creatorcontrib><creatorcontrib>Guerra Bálic, Myriam</creatorcontrib><creatorcontrib>Padullés Riu, Josep María</creatorcontrib><title>Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales</title><title>Revista internacional de ciencias del deporte</title><description>Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages. La medición de la altura del salto vertical es un indicador de la fuerza y potencia del tren inferior. Los instrumentos electrónicos disponibles para medir este salto son cajas negras que no permiten la verificación ni la adaptación por parte de terceros. Proponemos la creación de un sistema de medición llamado Chronojump-Boscosystem, que consiste en un hardware abierto y un software libre. Métodos: Se ha creado un microcontrolador y se ha validado usando un generador de ondas cuadradas y un osciloscopio. Se han desarrollado dos tipos de plataformas usando materiales distintos. Las plataformas se han validado determinando su sensibilidad en distintos puntos por medio de una célula de carga, y por comparación con la plataforma de contactos del sistema Ergojump-Boscosystem en una muestra de 8 sujetos, realizando saltos sub-máximos con un pie en cada plataforma. Se ha usado una metodología ágil para el desarrollo y validación del software. Resultados: Todas las partes que componen el sistema se han licenciado como software libre o hardware abierto. El margen de error del microcontrolador es de 0,1%. La validez de la plataforma de fibra de vidrio es de 0,95 (ICC). El software de gestión tiene cerca de 113 mil líneas de código y está disponible en 7 idiomas.</description><subject>biomechanics</subject><subject>biomecánica</subject><subject>boscosystem</subject><subject>chronojump</subject><subject>free software</subject><subject>hardware abierto</subject><subject>jump</subject><subject>open hardware</subject><subject>saltos</subject><subject>software libre</subject><issn>1885-3137</issn><issn>1885-3137</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>FKZ</sourceid><recordid>eNqljEtqw0AQRIfgQOwkd-gLCDQIyyJkkwibrIP3Q1vqkBbzEd0jg87lI-Ri8cIJ3rs2Va-g6s4sbdOsi8pWm8VVfjAr1aEs66bZ1EsTWyHs-OcUYYYjeu4v1BO035JiGqYwFu9Ju6SzZgovMEXgqFmmQDEn8HwQghEFwSME6vn_QdHnpHAkydyhJ30y91_olZ4v_mhed9t9-1H0jD5SdqNwQJldQnZ_3RRZOA3oSN3b5748a12X1trqxvkv5ethTw</recordid><startdate>2012</startdate><enddate>2012</enddate><creator>Blas Foix, Xavier de</creator><creator>López del Amo, José Luis</creator><creator>Guerra Bálic, Myriam</creator><creator>Padullés Riu, Josep María</creator><general>Ramón Cantó Alcaraz</general><scope>AGMXS</scope><scope>FKZ</scope></search><sort><creationdate>2012</creationdate><title>Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales</title><author>Blas Foix, Xavier de ; López del Amo, José Luis ; Guerra Bálic, Myriam ; Padullés Riu, Josep María</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dialnet_primary_oai_dialnet_unirioja_es_ART00005601113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>biomechanics</topic><topic>biomecánica</topic><topic>boscosystem</topic><topic>chronojump</topic><topic>free software</topic><topic>hardware abierto</topic><topic>jump</topic><topic>open hardware</topic><topic>saltos</topic><topic>software libre</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Blas Foix, Xavier de</creatorcontrib><creatorcontrib>López del Amo, José Luis</creatorcontrib><creatorcontrib>Guerra Bálic, Myriam</creatorcontrib><creatorcontrib>Padullés Riu, Josep María</creatorcontrib><collection>Dialnet (Open Access Full Text)</collection><collection>Dialnet</collection><jtitle>Revista internacional de ciencias del deporte</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Blas Foix, Xavier de</au><au>López del Amo, José Luis</au><au>Guerra Bálic, Myriam</au><au>Padullés Riu, Josep María</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales</atitle><jtitle>Revista internacional de ciencias del deporte</jtitle><date>2012</date><risdate>2012</risdate><volume>8</volume><issue>30</issue><spage>334</spage><epage>356</epage><pages>334-356</pages><issn>1885-3137</issn><eissn>1885-3137</eissn><abstract>Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages. La medición de la altura del salto vertical es un indicador de la fuerza y potencia del tren inferior. Los instrumentos electrónicos disponibles para medir este salto son cajas negras que no permiten la verificación ni la adaptación por parte de terceros. Proponemos la creación de un sistema de medición llamado Chronojump-Boscosystem, que consiste en un hardware abierto y un software libre. Métodos: Se ha creado un microcontrolador y se ha validado usando un generador de ondas cuadradas y un osciloscopio. Se han desarrollado dos tipos de plataformas usando materiales distintos. Las plataformas se han validado determinando su sensibilidad en distintos puntos por medio de una célula de carga, y por comparación con la plataforma de contactos del sistema Ergojump-Boscosystem en una muestra de 8 sujetos, realizando saltos sub-máximos con un pie en cada plataforma. Se ha usado una metodología ágil para el desarrollo y validación del software. Resultados: Todas las partes que componen el sistema se han licenciado como software libre o hardware abierto. El margen de error del microcontrolador es de 0,1%. La validez de la plataforma de fibra de vidrio es de 0,95 (ICC). El software de gestión tiene cerca de 113 mil líneas de código y está disponible en 7 idiomas.</abstract><pub>Ramón Cantó Alcaraz</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1885-3137
ispartof Revista internacional de ciencias del deporte, 2012, Vol.8 (30), p.334-356
issn 1885-3137
1885-3137
language eng
recordid cdi_dialnet_primary_oai_dialnet_unirioja_es_ART0000560111
source Dialnet; DOAJ Directory of Open Access Journals; EZB Electronic Journals Library
subjects biomechanics
biomecánica
boscosystem
chronojump
free software
hardware abierto
jump
open hardware
saltos
software libre
title Creación y validación de Chronojump-Boscosystem: un instrumento libre para la medición de saltos verticales
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T11%3A55%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dialnet&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Creaci%C3%B3n%20y%20validaci%C3%B3n%20de%20Chronojump-Boscosystem:%20un%20instrumento%20libre%20para%20la%20medici%C3%B3n%20de%20saltos%20verticales&rft.jtitle=Revista%20internacional%20de%20ciencias%20del%20deporte&rft.au=Blas%20Foix,%20Xavier%20de&rft.date=2012&rft.volume=8&rft.issue=30&rft.spage=334&rft.epage=356&rft.pages=334-356&rft.issn=1885-3137&rft.eissn=1885-3137&rft_id=info:doi/&rft_dat=%3Cdialnet%3Eoai_dialnet_unirioja_es_ART0000560111%3C/dialnet%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true