Effect of polishing technique on the surface topography and transmittance of the composite resin

Introduction:Clinically, it is common to observe the effects of composite restorations stratification only after the polishing.Aim:This study evaluated the effect of polishing technique on light transmittance and surface topography of a composite resin.Material and method:Specimens of the composite...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Souza, Marina Moura De Azevedo, Thaysa Monteiro Ramos, Gois, Diego Noronha De, Alaíde Hermínia De Aguiar Oliveira, Reis, Giselle Rodrigues, Murilo De Sousa Menezes, Faria-E-Silva, André Luis
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Souza, Marina Moura De Azevedo
Thaysa Monteiro Ramos
Gois, Diego Noronha De
Alaíde Hermínia De Aguiar Oliveira
Reis, Giselle Rodrigues
Murilo De Sousa Menezes
Faria-E-Silva, André Luis
description Introduction:Clinically, it is common to observe the effects of composite restorations stratification only after the polishing.Aim:This study evaluated the effect of polishing technique on light transmittance and surface topography of a composite resin.Material and method:Specimens of the composite resin Filtek Z-350 XT (color A1E) were built-up using a metal matrix. One of the specimens surfaces was finished with 12-blade burs and polished using one of following techniques: SL (Sof-Lex), EH (Enhance) and DH (DHPro). No polishing was used as control. After the polishing procedures, the samples were measured to check the final thickness (1 mm). The light transmittance was measured using a spectrophotometer connected to an integrating sphere, considered only light in the visible spectrum. The surface topography was measured by laser interferometer, assessing the parameters Sdq (hybrid), St (maximum amplitude) and Sa (average of peaks and valleys). Data (n=5) were submitted to ANOVA and SNK's test, while Pearson's correlation test was used to related Ssq, St and Sa to transmittance (α=0.05).Result:All polishing systems increased the light transmittance when compared to control, whereas no difference was observed between them. Only the samples polished with SL and DH showed lower Sdq values than control. Although for St and Sa parameters, EH showed lower values than those observed for control. Sdq and St showed significant correlation with transmittance.Conclusion:All polishing systems were effective to increase the transmittance, while the reduction of Sdq and St values were related to this modification.
doi_str_mv 10.6084/m9.figshare.7517201
format Dataset
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_6084_m9_figshare_7517201</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_6084_m9_figshare_7517201</sourcerecordid><originalsourceid>FETCH-LOGICAL-d891-24f4a2b13c34e2204532584b58710e5dff35274cd53e9eba87b5e828ebcac7593</originalsourceid><addsrcrecordid>eNo1j7tOwzAYhbMwoMITsPgFEnzFzoiqcpEqsXQ3f5zfiaXGDrY79O1pRZnOcI6-o69pnhjtXqiRz0vf-TCVGTJ2WjHNKbtvvnfeo6skebKmYyhziBOp6OYYfk5IUiR1RlJO2YNDUtOapgzrfCYQR1IzxLKEWiFeygviunVpWVMJFUnGEuJDc-fhWPDxlpvm8LY7bD_a_df75_Z1346mZy2XXgIfmHBCIudUKsGVkYMymlFUo_dCcS3dqAT2OIDRg0LDDQ4OnFa92DTiDztCBXd5t2sOC-SzZdRe9e3S2399e9MXvzMIWEs</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>dataset</recordtype></control><display><type>dataset</type><title>Effect of polishing technique on the surface topography and transmittance of the composite resin</title><source>DataCite</source><creator>Souza, Marina Moura De Azevedo ; Thaysa Monteiro Ramos ; Gois, Diego Noronha De ; Alaíde Hermínia De Aguiar Oliveira ; Reis, Giselle Rodrigues ; Murilo De Sousa Menezes ; Faria-E-Silva, André Luis</creator><creatorcontrib>Souza, Marina Moura De Azevedo ; Thaysa Monteiro Ramos ; Gois, Diego Noronha De ; Alaíde Hermínia De Aguiar Oliveira ; Reis, Giselle Rodrigues ; Murilo De Sousa Menezes ; Faria-E-Silva, André Luis</creatorcontrib><description>Introduction:Clinically, it is common to observe the effects of composite restorations stratification only after the polishing.Aim:This study evaluated the effect of polishing technique on light transmittance and surface topography of a composite resin.Material and method:Specimens of the composite resin Filtek Z-350 XT (color A1E) were built-up using a metal matrix. One of the specimens surfaces was finished with 12-blade burs and polished using one of following techniques: SL (Sof-Lex), EH (Enhance) and DH (DHPro). No polishing was used as control. After the polishing procedures, the samples were measured to check the final thickness (1 mm). The light transmittance was measured using a spectrophotometer connected to an integrating sphere, considered only light in the visible spectrum. The surface topography was measured by laser interferometer, assessing the parameters Sdq (hybrid), St (maximum amplitude) and Sa (average of peaks and valleys). Data (n=5) were submitted to ANOVA and SNK's test, while Pearson's correlation test was used to related Ssq, St and Sa to transmittance (α=0.05).Result:All polishing systems increased the light transmittance when compared to control, whereas no difference was observed between them. Only the samples polished with SL and DH showed lower Sdq values than control. Although for St and Sa parameters, EH showed lower values than those observed for control. Sdq and St showed significant correlation with transmittance.Conclusion:All polishing systems were effective to increase the transmittance, while the reduction of Sdq and St values were related to this modification.</description><identifier>DOI: 10.6084/m9.figshare.7517201</identifier><language>eng</language><publisher>SciELO journals</publisher><subject>Dentistry not elsewhere classified ; FOS: Clinical medicine</subject><creationdate>2018</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,1894</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.6084/m9.figshare.7517201$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Souza, Marina Moura De Azevedo</creatorcontrib><creatorcontrib>Thaysa Monteiro Ramos</creatorcontrib><creatorcontrib>Gois, Diego Noronha De</creatorcontrib><creatorcontrib>Alaíde Hermínia De Aguiar Oliveira</creatorcontrib><creatorcontrib>Reis, Giselle Rodrigues</creatorcontrib><creatorcontrib>Murilo De Sousa Menezes</creatorcontrib><creatorcontrib>Faria-E-Silva, André Luis</creatorcontrib><title>Effect of polishing technique on the surface topography and transmittance of the composite resin</title><description>Introduction:Clinically, it is common to observe the effects of composite restorations stratification only after the polishing.Aim:This study evaluated the effect of polishing technique on light transmittance and surface topography of a composite resin.Material and method:Specimens of the composite resin Filtek Z-350 XT (color A1E) were built-up using a metal matrix. One of the specimens surfaces was finished with 12-blade burs and polished using one of following techniques: SL (Sof-Lex), EH (Enhance) and DH (DHPro). No polishing was used as control. After the polishing procedures, the samples were measured to check the final thickness (1 mm). The light transmittance was measured using a spectrophotometer connected to an integrating sphere, considered only light in the visible spectrum. The surface topography was measured by laser interferometer, assessing the parameters Sdq (hybrid), St (maximum amplitude) and Sa (average of peaks and valleys). Data (n=5) were submitted to ANOVA and SNK's test, while Pearson's correlation test was used to related Ssq, St and Sa to transmittance (α=0.05).Result:All polishing systems increased the light transmittance when compared to control, whereas no difference was observed between them. Only the samples polished with SL and DH showed lower Sdq values than control. Although for St and Sa parameters, EH showed lower values than those observed for control. Sdq and St showed significant correlation with transmittance.Conclusion:All polishing systems were effective to increase the transmittance, while the reduction of Sdq and St values were related to this modification.</description><subject>Dentistry not elsewhere classified</subject><subject>FOS: Clinical medicine</subject><fulltext>true</fulltext><rsrctype>dataset</rsrctype><creationdate>2018</creationdate><recordtype>dataset</recordtype><sourceid>PQ8</sourceid><recordid>eNo1j7tOwzAYhbMwoMITsPgFEnzFzoiqcpEqsXQ3f5zfiaXGDrY79O1pRZnOcI6-o69pnhjtXqiRz0vf-TCVGTJ2WjHNKbtvvnfeo6skebKmYyhziBOp6OYYfk5IUiR1RlJO2YNDUtOapgzrfCYQR1IzxLKEWiFeygviunVpWVMJFUnGEuJDc-fhWPDxlpvm8LY7bD_a_df75_Z1346mZy2XXgIfmHBCIudUKsGVkYMymlFUo_dCcS3dqAT2OIDRg0LDDQ4OnFa92DTiDztCBXd5t2sOC-SzZdRe9e3S2399e9MXvzMIWEs</recordid><startdate>20181226</startdate><enddate>20181226</enddate><creator>Souza, Marina Moura De Azevedo</creator><creator>Thaysa Monteiro Ramos</creator><creator>Gois, Diego Noronha De</creator><creator>Alaíde Hermínia De Aguiar Oliveira</creator><creator>Reis, Giselle Rodrigues</creator><creator>Murilo De Sousa Menezes</creator><creator>Faria-E-Silva, André Luis</creator><general>SciELO journals</general><scope>DYCCY</scope><scope>PQ8</scope></search><sort><creationdate>20181226</creationdate><title>Effect of polishing technique on the surface topography and transmittance of the composite resin</title><author>Souza, Marina Moura De Azevedo ; Thaysa Monteiro Ramos ; Gois, Diego Noronha De ; Alaíde Hermínia De Aguiar Oliveira ; Reis, Giselle Rodrigues ; Murilo De Sousa Menezes ; Faria-E-Silva, André Luis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d891-24f4a2b13c34e2204532584b58710e5dff35274cd53e9eba87b5e828ebcac7593</frbrgroupid><rsrctype>datasets</rsrctype><prefilter>datasets</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Dentistry not elsewhere classified</topic><topic>FOS: Clinical medicine</topic><toplevel>online_resources</toplevel><creatorcontrib>Souza, Marina Moura De Azevedo</creatorcontrib><creatorcontrib>Thaysa Monteiro Ramos</creatorcontrib><creatorcontrib>Gois, Diego Noronha De</creatorcontrib><creatorcontrib>Alaíde Hermínia De Aguiar Oliveira</creatorcontrib><creatorcontrib>Reis, Giselle Rodrigues</creatorcontrib><creatorcontrib>Murilo De Sousa Menezes</creatorcontrib><creatorcontrib>Faria-E-Silva, André Luis</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Souza, Marina Moura De Azevedo</au><au>Thaysa Monteiro Ramos</au><au>Gois, Diego Noronha De</au><au>Alaíde Hermínia De Aguiar Oliveira</au><au>Reis, Giselle Rodrigues</au><au>Murilo De Sousa Menezes</au><au>Faria-E-Silva, André Luis</au><format>book</format><genre>unknown</genre><ristype>DATA</ristype><title>Effect of polishing technique on the surface topography and transmittance of the composite resin</title><date>2018-12-26</date><risdate>2018</risdate><abstract>Introduction:Clinically, it is common to observe the effects of composite restorations stratification only after the polishing.Aim:This study evaluated the effect of polishing technique on light transmittance and surface topography of a composite resin.Material and method:Specimens of the composite resin Filtek Z-350 XT (color A1E) were built-up using a metal matrix. One of the specimens surfaces was finished with 12-blade burs and polished using one of following techniques: SL (Sof-Lex), EH (Enhance) and DH (DHPro). No polishing was used as control. After the polishing procedures, the samples were measured to check the final thickness (1 mm). The light transmittance was measured using a spectrophotometer connected to an integrating sphere, considered only light in the visible spectrum. The surface topography was measured by laser interferometer, assessing the parameters Sdq (hybrid), St (maximum amplitude) and Sa (average of peaks and valleys). Data (n=5) were submitted to ANOVA and SNK's test, while Pearson's correlation test was used to related Ssq, St and Sa to transmittance (α=0.05).Result:All polishing systems increased the light transmittance when compared to control, whereas no difference was observed between them. Only the samples polished with SL and DH showed lower Sdq values than control. Although for St and Sa parameters, EH showed lower values than those observed for control. Sdq and St showed significant correlation with transmittance.Conclusion:All polishing systems were effective to increase the transmittance, while the reduction of Sdq and St values were related to this modification.</abstract><pub>SciELO journals</pub><doi>10.6084/m9.figshare.7517201</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.6084/m9.figshare.7517201
ispartof
issn
language eng
recordid cdi_datacite_primary_10_6084_m9_figshare_7517201
source DataCite
subjects Dentistry not elsewhere classified
FOS: Clinical medicine
title Effect of polishing technique on the surface topography and transmittance of the composite resin
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T11%3A01%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.au=Souza,%20Marina%20Moura%20De%20Azevedo&rft.date=2018-12-26&rft_id=info:doi/10.6084/m9.figshare.7517201&rft_dat=%3Cdatacite_PQ8%3E10_6084_m9_figshare_7517201%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true