Changes simulation in a conventional ETA midsize to safe water production

ABSTRACT This work involving the analysis of scenarios based on the proposition of operational and structural changes in water supply systems and their impacts on the quality of water supplied to the population. The aim of this study is to evaluate the impacts of structural and management alteration...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Nascimento, Ruth Silveira Do, Rosires Catão Curi, Curi, Wilson Fadlo, Oliveira, Rui De, Cícero Fellipe Diniz De Santana, Celeide Maria Belmont Sabino Meira
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Nascimento, Ruth Silveira Do
Rosires Catão Curi
Curi, Wilson Fadlo
Oliveira, Rui De
Cícero Fellipe Diniz De Santana
Celeide Maria Belmont Sabino Meira
description ABSTRACT This work involving the analysis of scenarios based on the proposition of operational and structural changes in water supply systems and their impacts on the quality of water supplied to the population. The aim of this study is to evaluate the impacts of structural and management alterations proposed for the water treatment plant on water quality in the network, based on the simulation of the behavior of free residual chlorine (FRC), as well as to evaluate the reduction the risks to the health of consumers, through the application of risk analysis method Failure Mode and Effect Analysis (FMEA), aiming a safe supply for the population of a medium-sized city. The simulation of water quality behavior was developed in the software EPANET 2.0, being the network map constructed from the network tracing of water supply network of two places of Campina Grande City, Paraíba state, Brazil. In the current scenario (C1) one of the places presented, on all nodes, FRC below the minimum recommended by the Ordinance of Brazilian Health Ministry; after the changes, simulated in scenario 2 (C2) an improvement of 60% was observed in the disinfectant concentration compliance with the minimumrecommended value. The risk assessment for C2 showed that the changes provided a reduction of about 66% of the risks in relation to C1. The simulation indicated that there is an improvement in the quality of water but it was concluded, however, that only promoting changes in the water treatment plant is not sufficient to ensure the same or higher concentrations of FRC equal or superior to 0.2mgCl2 /L, throughout the network.
doi_str_mv 10.6084/m9.figshare.7511183
format Dataset
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_6084_m9_figshare_7511183</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_6084_m9_figshare_7511183</sourcerecordid><originalsourceid>FETCH-LOGICAL-d893-966ea434baa60a29473e7c671c14a2dcfb1f7b271eb47e40937458329e6be71e3</originalsourceid><addsrcrecordid>eNo1j0FOwzAURL1hgQonYOMLJMSxa8fLKipQqRKb7K1v56e1FDuV7YLg9BBRVqMZPY30CHliTS2bTjwHXU_-lM-QsFZbxljH78mhP0M8YabZh-sMxS-R-kiBuiV-YFw7zHQ_7GjwY_bfSMtCM0xIP6Fgope0jFe3Yg_kboI54-MtN2R42Q_9W3V8fz30u2M1dppXWkoEwYUFkA20WiiOyknFHBPQjm6ybFK2VQytUCgazZXYdrzVKC3-rnxD-N_tCAWcL2guyQdIX4Y1ZvU0QZt_T3Pz5D8BBU8b</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>dataset</recordtype></control><display><type>dataset</type><title>Changes simulation in a conventional ETA midsize to safe water production</title><source>DataCite</source><creator>Nascimento, Ruth Silveira Do ; Rosires Catão Curi ; Curi, Wilson Fadlo ; Oliveira, Rui De ; Cícero Fellipe Diniz De Santana ; Celeide Maria Belmont Sabino Meira</creator><creatorcontrib>Nascimento, Ruth Silveira Do ; Rosires Catão Curi ; Curi, Wilson Fadlo ; Oliveira, Rui De ; Cícero Fellipe Diniz De Santana ; Celeide Maria Belmont Sabino Meira</creatorcontrib><description>ABSTRACT This work involving the analysis of scenarios based on the proposition of operational and structural changes in water supply systems and their impacts on the quality of water supplied to the population. The aim of this study is to evaluate the impacts of structural and management alterations proposed for the water treatment plant on water quality in the network, based on the simulation of the behavior of free residual chlorine (FRC), as well as to evaluate the reduction the risks to the health of consumers, through the application of risk analysis method Failure Mode and Effect Analysis (FMEA), aiming a safe supply for the population of a medium-sized city. The simulation of water quality behavior was developed in the software EPANET 2.0, being the network map constructed from the network tracing of water supply network of two places of Campina Grande City, Paraíba state, Brazil. In the current scenario (C1) one of the places presented, on all nodes, FRC below the minimum recommended by the Ordinance of Brazilian Health Ministry; after the changes, simulated in scenario 2 (C2) an improvement of 60% was observed in the disinfectant concentration compliance with the minimumrecommended value. The risk assessment for C2 showed that the changes provided a reduction of about 66% of the risks in relation to C1. The simulation indicated that there is an improvement in the quality of water but it was concluded, however, that only promoting changes in the water treatment plant is not sufficient to ensure the same or higher concentrations of FRC equal or superior to 0.2mgCl2 /L, throughout the network.</description><identifier>DOI: 10.6084/m9.figshare.7511183</identifier><language>eng</language><publisher>SciELO journals</publisher><subject>Engineering not elsewhere classified ; Engineering Practice ; FOS: Environmental engineering ; FOS: Other engineering and technologies ; Maritime Engineering not elsewhere classified ; Ocean Engineering</subject><creationdate>2018</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,1894</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.6084/m9.figshare.7511183$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Nascimento, Ruth Silveira Do</creatorcontrib><creatorcontrib>Rosires Catão Curi</creatorcontrib><creatorcontrib>Curi, Wilson Fadlo</creatorcontrib><creatorcontrib>Oliveira, Rui De</creatorcontrib><creatorcontrib>Cícero Fellipe Diniz De Santana</creatorcontrib><creatorcontrib>Celeide Maria Belmont Sabino Meira</creatorcontrib><title>Changes simulation in a conventional ETA midsize to safe water production</title><description>ABSTRACT This work involving the analysis of scenarios based on the proposition of operational and structural changes in water supply systems and their impacts on the quality of water supplied to the population. The aim of this study is to evaluate the impacts of structural and management alterations proposed for the water treatment plant on water quality in the network, based on the simulation of the behavior of free residual chlorine (FRC), as well as to evaluate the reduction the risks to the health of consumers, through the application of risk analysis method Failure Mode and Effect Analysis (FMEA), aiming a safe supply for the population of a medium-sized city. The simulation of water quality behavior was developed in the software EPANET 2.0, being the network map constructed from the network tracing of water supply network of two places of Campina Grande City, Paraíba state, Brazil. In the current scenario (C1) one of the places presented, on all nodes, FRC below the minimum recommended by the Ordinance of Brazilian Health Ministry; after the changes, simulated in scenario 2 (C2) an improvement of 60% was observed in the disinfectant concentration compliance with the minimumrecommended value. The risk assessment for C2 showed that the changes provided a reduction of about 66% of the risks in relation to C1. The simulation indicated that there is an improvement in the quality of water but it was concluded, however, that only promoting changes in the water treatment plant is not sufficient to ensure the same or higher concentrations of FRC equal or superior to 0.2mgCl2 /L, throughout the network.</description><subject>Engineering not elsewhere classified</subject><subject>Engineering Practice</subject><subject>FOS: Environmental engineering</subject><subject>FOS: Other engineering and technologies</subject><subject>Maritime Engineering not elsewhere classified</subject><subject>Ocean Engineering</subject><fulltext>true</fulltext><rsrctype>dataset</rsrctype><creationdate>2018</creationdate><recordtype>dataset</recordtype><sourceid>PQ8</sourceid><recordid>eNo1j0FOwzAURL1hgQonYOMLJMSxa8fLKipQqRKb7K1v56e1FDuV7YLg9BBRVqMZPY30CHliTS2bTjwHXU_-lM-QsFZbxljH78mhP0M8YabZh-sMxS-R-kiBuiV-YFw7zHQ_7GjwY_bfSMtCM0xIP6Fgope0jFe3Yg_kboI54-MtN2R42Q_9W3V8fz30u2M1dppXWkoEwYUFkA20WiiOyknFHBPQjm6ybFK2VQytUCgazZXYdrzVKC3-rnxD-N_tCAWcL2guyQdIX4Y1ZvU0QZt_T3Pz5D8BBU8b</recordid><startdate>20181226</startdate><enddate>20181226</enddate><creator>Nascimento, Ruth Silveira Do</creator><creator>Rosires Catão Curi</creator><creator>Curi, Wilson Fadlo</creator><creator>Oliveira, Rui De</creator><creator>Cícero Fellipe Diniz De Santana</creator><creator>Celeide Maria Belmont Sabino Meira</creator><general>SciELO journals</general><scope>DYCCY</scope><scope>PQ8</scope></search><sort><creationdate>20181226</creationdate><title>Changes simulation in a conventional ETA midsize to safe water production</title><author>Nascimento, Ruth Silveira Do ; Rosires Catão Curi ; Curi, Wilson Fadlo ; Oliveira, Rui De ; Cícero Fellipe Diniz De Santana ; Celeide Maria Belmont Sabino Meira</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d893-966ea434baa60a29473e7c671c14a2dcfb1f7b271eb47e40937458329e6be71e3</frbrgroupid><rsrctype>datasets</rsrctype><prefilter>datasets</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Engineering not elsewhere classified</topic><topic>Engineering Practice</topic><topic>FOS: Environmental engineering</topic><topic>FOS: Other engineering and technologies</topic><topic>Maritime Engineering not elsewhere classified</topic><topic>Ocean Engineering</topic><toplevel>online_resources</toplevel><creatorcontrib>Nascimento, Ruth Silveira Do</creatorcontrib><creatorcontrib>Rosires Catão Curi</creatorcontrib><creatorcontrib>Curi, Wilson Fadlo</creatorcontrib><creatorcontrib>Oliveira, Rui De</creatorcontrib><creatorcontrib>Cícero Fellipe Diniz De Santana</creatorcontrib><creatorcontrib>Celeide Maria Belmont Sabino Meira</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Nascimento, Ruth Silveira Do</au><au>Rosires Catão Curi</au><au>Curi, Wilson Fadlo</au><au>Oliveira, Rui De</au><au>Cícero Fellipe Diniz De Santana</au><au>Celeide Maria Belmont Sabino Meira</au><format>book</format><genre>unknown</genre><ristype>DATA</ristype><title>Changes simulation in a conventional ETA midsize to safe water production</title><date>2018-12-26</date><risdate>2018</risdate><abstract>ABSTRACT This work involving the analysis of scenarios based on the proposition of operational and structural changes in water supply systems and their impacts on the quality of water supplied to the population. The aim of this study is to evaluate the impacts of structural and management alterations proposed for the water treatment plant on water quality in the network, based on the simulation of the behavior of free residual chlorine (FRC), as well as to evaluate the reduction the risks to the health of consumers, through the application of risk analysis method Failure Mode and Effect Analysis (FMEA), aiming a safe supply for the population of a medium-sized city. The simulation of water quality behavior was developed in the software EPANET 2.0, being the network map constructed from the network tracing of water supply network of two places of Campina Grande City, Paraíba state, Brazil. In the current scenario (C1) one of the places presented, on all nodes, FRC below the minimum recommended by the Ordinance of Brazilian Health Ministry; after the changes, simulated in scenario 2 (C2) an improvement of 60% was observed in the disinfectant concentration compliance with the minimumrecommended value. The risk assessment for C2 showed that the changes provided a reduction of about 66% of the risks in relation to C1. The simulation indicated that there is an improvement in the quality of water but it was concluded, however, that only promoting changes in the water treatment plant is not sufficient to ensure the same or higher concentrations of FRC equal or superior to 0.2mgCl2 /L, throughout the network.</abstract><pub>SciELO journals</pub><doi>10.6084/m9.figshare.7511183</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.6084/m9.figshare.7511183
ispartof
issn
language eng
recordid cdi_datacite_primary_10_6084_m9_figshare_7511183
source DataCite
subjects Engineering not elsewhere classified
Engineering Practice
FOS: Environmental engineering
FOS: Other engineering and technologies
Maritime Engineering not elsewhere classified
Ocean Engineering
title Changes simulation in a conventional ETA midsize to safe water production
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T22%3A04%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.au=Nascimento,%20Ruth%20Silveira%20Do&rft.date=2018-12-26&rft_id=info:doi/10.6084/m9.figshare.7511183&rft_dat=%3Cdatacite_PQ8%3E10_6084_m9_figshare_7511183%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true