Immunodetection of D-dimer on a microfluidic paper-based analytical device

A microfluidic paper-based analytical device (µPAD) was created by wax printing on a single piece of Whatman N. 1 chromatographic paper (1.5 cm x 4.5 cm, 0.18 mm thick) and combined with an anti-D-dimer capture antibody and conjugates of anti-D-dimer antibody with 40 nm gold nanoparticles. The desig...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Prazeres, Duarte Miguel, Azevedo, Ana Margarida, Ruivo, Sónia
Format: Video
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Prazeres, Duarte Miguel
Azevedo, Ana Margarida
Ruivo, Sónia
description A microfluidic paper-based analytical device (µPAD) was created by wax printing on a single piece of Whatman N. 1 chromatographic paper (1.5 cm x 4.5 cm, 0.18 mm thick) and combined with an anti-D-dimer capture antibody and conjugates of anti-D-dimer antibody with 40 nm gold nanoparticles. The design comprises: i) a circular area (ID 0.5 cm) for sample addition (S), ii) a linear channel (2.6 cm long), iii) circular areas where test (T) and control (C) reactions take place (ID 0.5 cm) and iv) a rectangular reservoir (1.0 cm x 1.4 cm). The μPAD on the top was used to test a sample with 1 x 105 ng/mL D-dimer (12 μL), whereas the μPAD on the bottom was run with a control (no D-dimer) sample. The video clearly shows the capture of the D-dimer:antibody-AuNP complex by the antibody immobilized in the circular test zone in the top μPAD. This capture is signaled by the formation of a red spot, which is absent in the test zone of the bottom µPAD, which was run with a control (no D-dimer) sample.
doi_str_mv 10.6084/m9.figshare.5217331
format Video
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_6084_m9_figshare_5217331</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_6084_m9_figshare_5217331</sourcerecordid><originalsourceid>FETCH-datacite_primary_10_6084_m9_figshare_52173313</originalsourceid><addsrcrecordid>eNqdzksOwiAUhWEmDoy6AidsoLWIr459RB07J1e46E2gEEpNuns1qRtwdPIPTvIxNhdVual2q4WvS0uP9gkJy_VSbKUUY3a9eN81wWBGnSk0PFh-KAx5TPxTwD3pFKzryJDmESKm4g4tGg4NuD6TBscNvkjjlI0suBZnw06YPB1v-3NhIIOmjCom8pB6JSr1FSlfq59IDSL53-sNAktJnA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>video</recordtype></control><display><type>video</type><title>Immunodetection of D-dimer on a microfluidic paper-based analytical device</title><source>DataCite</source><creator>Prazeres, Duarte Miguel ; Azevedo, Ana Margarida ; Ruivo, Sónia</creator><creatorcontrib>Prazeres, Duarte Miguel ; Azevedo, Ana Margarida ; Ruivo, Sónia</creatorcontrib><description>A microfluidic paper-based analytical device (µPAD) was created by wax printing on a single piece of Whatman N. 1 chromatographic paper (1.5 cm x 4.5 cm, 0.18 mm thick) and combined with an anti-D-dimer capture antibody and conjugates of anti-D-dimer antibody with 40 nm gold nanoparticles. The design comprises: i) a circular area (ID 0.5 cm) for sample addition (S), ii) a linear channel (2.6 cm long), iii) circular areas where test (T) and control (C) reactions take place (ID 0.5 cm) and iv) a rectangular reservoir (1.0 cm x 1.4 cm). The μPAD on the top was used to test a sample with 1 x 105 ng/mL D-dimer (12 μL), whereas the μPAD on the bottom was run with a control (no D-dimer) sample. The video clearly shows the capture of the D-dimer:antibody-AuNP complex by the antibody immobilized in the circular test zone in the top μPAD. This capture is signaled by the formation of a red spot, which is absent in the test zone of the bottom µPAD, which was run with a control (no D-dimer) sample.</description><identifier>DOI: 10.6084/m9.figshare.5217331</identifier><language>eng</language><publisher>figshare</publisher><subject>Analytical Biochemistry ; Analytical Chemistry not elsewhere classified ; Biochemistry and Cell Biology not elsewhere classified ; Biological Engineering ; Biological Techniques ; Biotechnology ; FOS: Biological sciences ; FOS: Chemical sciences ; FOS: Medical biotechnology ; FOS: Nanotechnology ; Medical Biotechnology Diagnostics (incl. Biosensors) ; Nanobiotechnology</subject><creationdate>2017</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0002-6928-692X ; 0000-0001-5659-466X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,1894</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.6084/m9.figshare.5217331$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Prazeres, Duarte Miguel</creatorcontrib><creatorcontrib>Azevedo, Ana Margarida</creatorcontrib><creatorcontrib>Ruivo, Sónia</creatorcontrib><title>Immunodetection of D-dimer on a microfluidic paper-based analytical device</title><description>A microfluidic paper-based analytical device (µPAD) was created by wax printing on a single piece of Whatman N. 1 chromatographic paper (1.5 cm x 4.5 cm, 0.18 mm thick) and combined with an anti-D-dimer capture antibody and conjugates of anti-D-dimer antibody with 40 nm gold nanoparticles. The design comprises: i) a circular area (ID 0.5 cm) for sample addition (S), ii) a linear channel (2.6 cm long), iii) circular areas where test (T) and control (C) reactions take place (ID 0.5 cm) and iv) a rectangular reservoir (1.0 cm x 1.4 cm). The μPAD on the top was used to test a sample with 1 x 105 ng/mL D-dimer (12 μL), whereas the μPAD on the bottom was run with a control (no D-dimer) sample. The video clearly shows the capture of the D-dimer:antibody-AuNP complex by the antibody immobilized in the circular test zone in the top μPAD. This capture is signaled by the formation of a red spot, which is absent in the test zone of the bottom µPAD, which was run with a control (no D-dimer) sample.</description><subject>Analytical Biochemistry</subject><subject>Analytical Chemistry not elsewhere classified</subject><subject>Biochemistry and Cell Biology not elsewhere classified</subject><subject>Biological Engineering</subject><subject>Biological Techniques</subject><subject>Biotechnology</subject><subject>FOS: Biological sciences</subject><subject>FOS: Chemical sciences</subject><subject>FOS: Medical biotechnology</subject><subject>FOS: Nanotechnology</subject><subject>Medical Biotechnology Diagnostics (incl. Biosensors)</subject><subject>Nanobiotechnology</subject><fulltext>true</fulltext><rsrctype>video</rsrctype><creationdate>2017</creationdate><recordtype>video</recordtype><sourceid>PQ8</sourceid><recordid>eNqdzksOwiAUhWEmDoy6AidsoLWIr459RB07J1e46E2gEEpNuns1qRtwdPIPTvIxNhdVual2q4WvS0uP9gkJy_VSbKUUY3a9eN81wWBGnSk0PFh-KAx5TPxTwD3pFKzryJDmESKm4g4tGg4NuD6TBscNvkjjlI0suBZnw06YPB1v-3NhIIOmjCom8pB6JSr1FSlfq59IDSL53-sNAktJnA</recordid><startdate>20170718</startdate><enddate>20170718</enddate><creator>Prazeres, Duarte Miguel</creator><creator>Azevedo, Ana Margarida</creator><creator>Ruivo, Sónia</creator><general>figshare</general><scope>DYCCY</scope><scope>PQ8</scope><orcidid>https://orcid.org/0000-0002-6928-692X</orcidid><orcidid>https://orcid.org/0000-0001-5659-466X</orcidid></search><sort><creationdate>20170718</creationdate><title>Immunodetection of D-dimer on a microfluidic paper-based analytical device</title><author>Prazeres, Duarte Miguel ; Azevedo, Ana Margarida ; Ruivo, Sónia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-datacite_primary_10_6084_m9_figshare_52173313</frbrgroupid><rsrctype>videos</rsrctype><prefilter>videos</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Analytical Biochemistry</topic><topic>Analytical Chemistry not elsewhere classified</topic><topic>Biochemistry and Cell Biology not elsewhere classified</topic><topic>Biological Engineering</topic><topic>Biological Techniques</topic><topic>Biotechnology</topic><topic>FOS: Biological sciences</topic><topic>FOS: Chemical sciences</topic><topic>FOS: Medical biotechnology</topic><topic>FOS: Nanotechnology</topic><topic>Medical Biotechnology Diagnostics (incl. Biosensors)</topic><topic>Nanobiotechnology</topic><toplevel>online_resources</toplevel><creatorcontrib>Prazeres, Duarte Miguel</creatorcontrib><creatorcontrib>Azevedo, Ana Margarida</creatorcontrib><creatorcontrib>Ruivo, Sónia</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Prazeres, Duarte Miguel</au><au>Azevedo, Ana Margarida</au><au>Ruivo, Sónia</au><genre>unknown</genre><ristype>VIDEO</ristype><title>Immunodetection of D-dimer on a microfluidic paper-based analytical device</title><date>2017-07-18</date><risdate>2017</risdate><abstract>A microfluidic paper-based analytical device (µPAD) was created by wax printing on a single piece of Whatman N. 1 chromatographic paper (1.5 cm x 4.5 cm, 0.18 mm thick) and combined with an anti-D-dimer capture antibody and conjugates of anti-D-dimer antibody with 40 nm gold nanoparticles. The design comprises: i) a circular area (ID 0.5 cm) for sample addition (S), ii) a linear channel (2.6 cm long), iii) circular areas where test (T) and control (C) reactions take place (ID 0.5 cm) and iv) a rectangular reservoir (1.0 cm x 1.4 cm). The μPAD on the top was used to test a sample with 1 x 105 ng/mL D-dimer (12 μL), whereas the μPAD on the bottom was run with a control (no D-dimer) sample. The video clearly shows the capture of the D-dimer:antibody-AuNP complex by the antibody immobilized in the circular test zone in the top μPAD. This capture is signaled by the formation of a red spot, which is absent in the test zone of the bottom µPAD, which was run with a control (no D-dimer) sample.</abstract><pub>figshare</pub><doi>10.6084/m9.figshare.5217331</doi><orcidid>https://orcid.org/0000-0002-6928-692X</orcidid><orcidid>https://orcid.org/0000-0001-5659-466X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.6084/m9.figshare.5217331
ispartof
issn
language eng
recordid cdi_datacite_primary_10_6084_m9_figshare_5217331
source DataCite
subjects Analytical Biochemistry
Analytical Chemistry not elsewhere classified
Biochemistry and Cell Biology not elsewhere classified
Biological Engineering
Biological Techniques
Biotechnology
FOS: Biological sciences
FOS: Chemical sciences
FOS: Medical biotechnology
FOS: Nanotechnology
Medical Biotechnology Diagnostics (incl. Biosensors)
Nanobiotechnology
title Immunodetection of D-dimer on a microfluidic paper-based analytical device
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T00%3A17%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:&rft.genre=unknown&rft.au=Prazeres,%20Duarte%20Miguel&rft.date=2017-07-18&rft_id=info:doi/10.6084/m9.figshare.5217331&rft_dat=%3Cdatacite_PQ8%3E10_6084_m9_figshare_5217331%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true