Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks

It is extremely important that the quality control of the concrete block used in structural masonry is conducted based on standard procedures that allow reliable estimation of the properties of these components. This work aims to analyze and evaluate the influence of the concrete block moisture on t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Parsekian, Guilherme Aris, Christoforo, André Luis, Mazzú, Amanda Duarte Escobal, Gláucia Maria Dalfré
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Parsekian, Guilherme Aris
Christoforo, André Luis
Mazzú, Amanda Duarte Escobal
Gláucia Maria Dalfré
description It is extremely important that the quality control of the concrete block used in structural masonry is conducted based on standard procedures that allow reliable estimation of the properties of these components. This work aims to analyze and evaluate the influence of the concrete block moisture on the result of the compression test. Hollow concrete blocks were prepared and subsequently maintained in different environments for various periods of time and under different conditions of temperature and humidity to determine the influence of the type of drying on the relative humidity of the block at the time of testing and consequently on its compressive strength. As a conclusion, it can be stated that, because it is necessary to use water in the process, the grinding rectification of the faces of the blocks led them to have high humidity, above 70%. If tested in this condition, the results of the compressive strength tests will be lower than that of blocks under usual environmental conditions. No differences were found in the average block strength when they were kept dry in the controlled environment of the laboratory during periods of 24 or 48 h. After grinding, it is not necessary to dry the blocks inside an oven at 40ºC before the tests; simply leaving them at a usual room temperature of 23ºC and humidity of 40 ± 5% for 24h is sufficient. The attempt to accelerate drying in an oven at 100ºC is not adequate because this leads to an increase in the compressive strength. From the results, it was possible to determine expressions to correlate the compressive strength as a function of the moisture of the block at the time of the test. The best-fit expressions are distinct for each block type, but the formulations are consistent in indicating a considerable difference in resistance as a function of moisture.
doi_str_mv 10.6084/m9.figshare.14307357
format Dataset
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_6084_m9_figshare_14307357</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_6084_m9_figshare_14307357</sourcerecordid><originalsourceid>FETCH-LOGICAL-d917-2229a72bfdbab0472fe6c85bbc42ac59d2a66f63092b4d476deebc8a3ccbf5343</originalsourceid><addsrcrecordid>eNo1kLtOAzEURN1QoMAfUPgHdtm1vQ_ToQgIUiSa9Nb19XVisS_ZXqT8PYkg1YyORlMcxp7qqmyrXj2PuvThmE4QqayVrDrZdPcMdusYXMhnDpPjaSEMI018ibRAhBzma5-R3BrphYfJDytNSPzCcR4vs5TCD_GUI03HfOKzv_AJI2XidpjxOz2wOw9Dosf_3LDD-9thuyv2Xx-f29d94XTdFUIIDZ2w3lmwleqEpxb7xlpUArDRTkDb-lZWWljlVNc6Ios9SETrG6nkhqm_WwcZMGQySwwjxLOpK3MVYEZtbgLMTYD8BR31WtE</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>dataset</recordtype></control><display><type>dataset</type><title>Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks</title><source>DataCite</source><creator>Parsekian, Guilherme Aris ; Christoforo, André Luis ; Mazzú, Amanda Duarte Escobal ; Gláucia Maria Dalfré</creator><creatorcontrib>Parsekian, Guilherme Aris ; Christoforo, André Luis ; Mazzú, Amanda Duarte Escobal ; Gláucia Maria Dalfré</creatorcontrib><description>It is extremely important that the quality control of the concrete block used in structural masonry is conducted based on standard procedures that allow reliable estimation of the properties of these components. This work aims to analyze and evaluate the influence of the concrete block moisture on the result of the compression test. Hollow concrete blocks were prepared and subsequently maintained in different environments for various periods of time and under different conditions of temperature and humidity to determine the influence of the type of drying on the relative humidity of the block at the time of testing and consequently on its compressive strength. As a conclusion, it can be stated that, because it is necessary to use water in the process, the grinding rectification of the faces of the blocks led them to have high humidity, above 70%. If tested in this condition, the results of the compressive strength tests will be lower than that of blocks under usual environmental conditions. No differences were found in the average block strength when they were kept dry in the controlled environment of the laboratory during periods of 24 or 48 h. After grinding, it is not necessary to dry the blocks inside an oven at 40ºC before the tests; simply leaving them at a usual room temperature of 23ºC and humidity of 40 ± 5% for 24h is sufficient. The attempt to accelerate drying in an oven at 100ºC is not adequate because this leads to an increase in the compressive strength. From the results, it was possible to determine expressions to correlate the compressive strength as a function of the moisture of the block at the time of the test. The best-fit expressions are distinct for each block type, but the formulations are consistent in indicating a considerable difference in resistance as a function of moisture.</description><identifier>DOI: 10.6084/m9.figshare.14307357</identifier><language>eng</language><publisher>SciELO journals</publisher><subject>Civil Geotechnical Engineering ; FOS: Civil engineering</subject><creationdate>2021</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>776,1888</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.6084/m9.figshare.14307357$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Parsekian, Guilherme Aris</creatorcontrib><creatorcontrib>Christoforo, André Luis</creatorcontrib><creatorcontrib>Mazzú, Amanda Duarte Escobal</creatorcontrib><creatorcontrib>Gláucia Maria Dalfré</creatorcontrib><title>Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks</title><description>It is extremely important that the quality control of the concrete block used in structural masonry is conducted based on standard procedures that allow reliable estimation of the properties of these components. This work aims to analyze and evaluate the influence of the concrete block moisture on the result of the compression test. Hollow concrete blocks were prepared and subsequently maintained in different environments for various periods of time and under different conditions of temperature and humidity to determine the influence of the type of drying on the relative humidity of the block at the time of testing and consequently on its compressive strength. As a conclusion, it can be stated that, because it is necessary to use water in the process, the grinding rectification of the faces of the blocks led them to have high humidity, above 70%. If tested in this condition, the results of the compressive strength tests will be lower than that of blocks under usual environmental conditions. No differences were found in the average block strength when they were kept dry in the controlled environment of the laboratory during periods of 24 or 48 h. After grinding, it is not necessary to dry the blocks inside an oven at 40ºC before the tests; simply leaving them at a usual room temperature of 23ºC and humidity of 40 ± 5% for 24h is sufficient. The attempt to accelerate drying in an oven at 100ºC is not adequate because this leads to an increase in the compressive strength. From the results, it was possible to determine expressions to correlate the compressive strength as a function of the moisture of the block at the time of the test. The best-fit expressions are distinct for each block type, but the formulations are consistent in indicating a considerable difference in resistance as a function of moisture.</description><subject>Civil Geotechnical Engineering</subject><subject>FOS: Civil engineering</subject><fulltext>true</fulltext><rsrctype>dataset</rsrctype><creationdate>2021</creationdate><recordtype>dataset</recordtype><sourceid>PQ8</sourceid><recordid>eNo1kLtOAzEURN1QoMAfUPgHdtm1vQ_ToQgIUiSa9Nb19XVisS_ZXqT8PYkg1YyORlMcxp7qqmyrXj2PuvThmE4QqayVrDrZdPcMdusYXMhnDpPjaSEMI018ibRAhBzma5-R3BrphYfJDytNSPzCcR4vs5TCD_GUI03HfOKzv_AJI2XidpjxOz2wOw9Dosf_3LDD-9thuyv2Xx-f29d94XTdFUIIDZ2w3lmwleqEpxb7xlpUArDRTkDb-lZWWljlVNc6Ios9SETrG6nkhqm_WwcZMGQySwwjxLOpK3MVYEZtbgLMTYD8BR31WtE</recordid><startdate>20210325</startdate><enddate>20210325</enddate><creator>Parsekian, Guilherme Aris</creator><creator>Christoforo, André Luis</creator><creator>Mazzú, Amanda Duarte Escobal</creator><creator>Gláucia Maria Dalfré</creator><general>SciELO journals</general><scope>DYCCY</scope><scope>PQ8</scope></search><sort><creationdate>20210325</creationdate><title>Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks</title><author>Parsekian, Guilherme Aris ; Christoforo, André Luis ; Mazzú, Amanda Duarte Escobal ; Gláucia Maria Dalfré</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d917-2229a72bfdbab0472fe6c85bbc42ac59d2a66f63092b4d476deebc8a3ccbf5343</frbrgroupid><rsrctype>datasets</rsrctype><prefilter>datasets</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Civil Geotechnical Engineering</topic><topic>FOS: Civil engineering</topic><toplevel>online_resources</toplevel><creatorcontrib>Parsekian, Guilherme Aris</creatorcontrib><creatorcontrib>Christoforo, André Luis</creatorcontrib><creatorcontrib>Mazzú, Amanda Duarte Escobal</creatorcontrib><creatorcontrib>Gláucia Maria Dalfré</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Parsekian, Guilherme Aris</au><au>Christoforo, André Luis</au><au>Mazzú, Amanda Duarte Escobal</au><au>Gláucia Maria Dalfré</au><format>book</format><genre>unknown</genre><ristype>DATA</ristype><title>Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks</title><date>2021-03-25</date><risdate>2021</risdate><abstract>It is extremely important that the quality control of the concrete block used in structural masonry is conducted based on standard procedures that allow reliable estimation of the properties of these components. This work aims to analyze and evaluate the influence of the concrete block moisture on the result of the compression test. Hollow concrete blocks were prepared and subsequently maintained in different environments for various periods of time and under different conditions of temperature and humidity to determine the influence of the type of drying on the relative humidity of the block at the time of testing and consequently on its compressive strength. As a conclusion, it can be stated that, because it is necessary to use water in the process, the grinding rectification of the faces of the blocks led them to have high humidity, above 70%. If tested in this condition, the results of the compressive strength tests will be lower than that of blocks under usual environmental conditions. No differences were found in the average block strength when they were kept dry in the controlled environment of the laboratory during periods of 24 or 48 h. After grinding, it is not necessary to dry the blocks inside an oven at 40ºC before the tests; simply leaving them at a usual room temperature of 23ºC and humidity of 40 ± 5% for 24h is sufficient. The attempt to accelerate drying in an oven at 100ºC is not adequate because this leads to an increase in the compressive strength. From the results, it was possible to determine expressions to correlate the compressive strength as a function of the moisture of the block at the time of the test. The best-fit expressions are distinct for each block type, but the formulations are consistent in indicating a considerable difference in resistance as a function of moisture.</abstract><pub>SciELO journals</pub><doi>10.6084/m9.figshare.14307357</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.6084/m9.figshare.14307357
ispartof
issn
language eng
recordid cdi_datacite_primary_10_6084_m9_figshare_14307357
source DataCite
subjects Civil Geotechnical Engineering
FOS: Civil engineering
title Humidity and specimen preparation procedure: influence on compressive strength of concrete blocks
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T02%3A26%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.au=Parsekian,%20Guilherme%20Aris&rft.date=2021-03-25&rft_id=info:doi/10.6084/m9.figshare.14307357&rft_dat=%3Cdatacite_PQ8%3E10_6084_m9_figshare_14307357%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true