Reinforced concrete flat slabs with openings at different distances from the column

The increase in the use of flat slabs and the need of the openings for the passage of installations, such as hydraulic and electrical, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extrem...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lourenço, Diego Da Silva, Elyson Andrew Pozo Liberati, Marques, Marília Gonçalves, Luiz Carlos De Almeida, Trautwein, Leandro Mouta
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Lourenço, Diego Da Silva
Elyson Andrew Pozo Liberati
Marques, Marília Gonçalves
Luiz Carlos De Almeida
Trautwein, Leandro Mouta
description The increase in the use of flat slabs and the need of the openings for the passage of installations, such as hydraulic and electrical, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extremely necessary. The influence in the structural behaviour of flat slabs with openings at different distances from the column was investigated through five square slabs (1,800 mm x 1,800 mm x 130 mm) supported on square columns (150 mm x 150 mm) tested until failure. The results obtained experimentally were compared with results available in the literature, as well as with responses predicted from the normative instructions. The results confirm high stresses concentration in the region between the column and the opening and that opening situated at 3d from the column have no influence on the failure load for the tested slabs.
doi_str_mv 10.6084/m9.figshare.14307324
format Dataset
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_6084_m9_figshare_14307324</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_6084_m9_figshare_14307324</sourcerecordid><originalsourceid>FETCH-LOGICAL-d914-446b2b83f14ad7ebc436d251d40e113a47ae118f4fa88af8e9c2c443dd0ffffb3</originalsourceid><addsrcrecordid>eNo1j81KxDAUhbtxIaNv4CIv0Jo01zZdyuAfDAg6-3Cb3DsTaNMhiYhvbweds_kOZ3Hgq6o7JZtOGrifh4bDIR8xUaNAy163cF19flCIvCRHXrglukSFBE9YRJ5wzOI7lKNYThRDPGSxzj4wU6J4brlgdJQFp2UW5Ujrw_Q1x5vqinHKdPvPTbV_ftpvX-vd-8vb9nFX-0FBDdCN7Wg0K0Df0-hAd759UB4kKaURelxpGBiNQTY0uNYBaO8lrxn1poK_W48FXShkTynMmH6skvasbOfBXpTtRVn_AuFIVKs</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>dataset</recordtype></control><display><type>dataset</type><title>Reinforced concrete flat slabs with openings at different distances from the column</title><source>DataCite</source><creator>Lourenço, Diego Da Silva ; Elyson Andrew Pozo Liberati ; Marques, Marília Gonçalves ; Luiz Carlos De Almeida ; Trautwein, Leandro Mouta</creator><creatorcontrib>Lourenço, Diego Da Silva ; Elyson Andrew Pozo Liberati ; Marques, Marília Gonçalves ; Luiz Carlos De Almeida ; Trautwein, Leandro Mouta</creatorcontrib><description>The increase in the use of flat slabs and the need of the openings for the passage of installations, such as hydraulic and electrical, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extremely necessary. The influence in the structural behaviour of flat slabs with openings at different distances from the column was investigated through five square slabs (1,800 mm x 1,800 mm x 130 mm) supported on square columns (150 mm x 150 mm) tested until failure. The results obtained experimentally were compared with results available in the literature, as well as with responses predicted from the normative instructions. The results confirm high stresses concentration in the region between the column and the opening and that opening situated at 3d from the column have no influence on the failure load for the tested slabs.</description><identifier>DOI: 10.6084/m9.figshare.14307324</identifier><language>eng</language><publisher>SciELO journals</publisher><subject>Civil Geotechnical Engineering ; FOS: Civil engineering</subject><creationdate>2021</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>778,1890</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.6084/m9.figshare.14307324$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Lourenço, Diego Da Silva</creatorcontrib><creatorcontrib>Elyson Andrew Pozo Liberati</creatorcontrib><creatorcontrib>Marques, Marília Gonçalves</creatorcontrib><creatorcontrib>Luiz Carlos De Almeida</creatorcontrib><creatorcontrib>Trautwein, Leandro Mouta</creatorcontrib><title>Reinforced concrete flat slabs with openings at different distances from the column</title><description>The increase in the use of flat slabs and the need of the openings for the passage of installations, such as hydraulic and electrical, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extremely necessary. The influence in the structural behaviour of flat slabs with openings at different distances from the column was investigated through five square slabs (1,800 mm x 1,800 mm x 130 mm) supported on square columns (150 mm x 150 mm) tested until failure. The results obtained experimentally were compared with results available in the literature, as well as with responses predicted from the normative instructions. The results confirm high stresses concentration in the region between the column and the opening and that opening situated at 3d from the column have no influence on the failure load for the tested slabs.</description><subject>Civil Geotechnical Engineering</subject><subject>FOS: Civil engineering</subject><fulltext>true</fulltext><rsrctype>dataset</rsrctype><creationdate>2021</creationdate><recordtype>dataset</recordtype><sourceid>PQ8</sourceid><recordid>eNo1j81KxDAUhbtxIaNv4CIv0Jo01zZdyuAfDAg6-3Cb3DsTaNMhiYhvbweds_kOZ3Hgq6o7JZtOGrifh4bDIR8xUaNAy163cF19flCIvCRHXrglukSFBE9YRJ5wzOI7lKNYThRDPGSxzj4wU6J4brlgdJQFp2UW5Ujrw_Q1x5vqinHKdPvPTbV_ftpvX-vd-8vb9nFX-0FBDdCN7Wg0K0Df0-hAd759UB4kKaURelxpGBiNQTY0uNYBaO8lrxn1poK_W48FXShkTynMmH6skvasbOfBXpTtRVn_AuFIVKs</recordid><startdate>20210325</startdate><enddate>20210325</enddate><creator>Lourenço, Diego Da Silva</creator><creator>Elyson Andrew Pozo Liberati</creator><creator>Marques, Marília Gonçalves</creator><creator>Luiz Carlos De Almeida</creator><creator>Trautwein, Leandro Mouta</creator><general>SciELO journals</general><scope>DYCCY</scope><scope>PQ8</scope></search><sort><creationdate>20210325</creationdate><title>Reinforced concrete flat slabs with openings at different distances from the column</title><author>Lourenço, Diego Da Silva ; Elyson Andrew Pozo Liberati ; Marques, Marília Gonçalves ; Luiz Carlos De Almeida ; Trautwein, Leandro Mouta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d914-446b2b83f14ad7ebc436d251d40e113a47ae118f4fa88af8e9c2c443dd0ffffb3</frbrgroupid><rsrctype>datasets</rsrctype><prefilter>datasets</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Civil Geotechnical Engineering</topic><topic>FOS: Civil engineering</topic><toplevel>online_resources</toplevel><creatorcontrib>Lourenço, Diego Da Silva</creatorcontrib><creatorcontrib>Elyson Andrew Pozo Liberati</creatorcontrib><creatorcontrib>Marques, Marília Gonçalves</creatorcontrib><creatorcontrib>Luiz Carlos De Almeida</creatorcontrib><creatorcontrib>Trautwein, Leandro Mouta</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Lourenço, Diego Da Silva</au><au>Elyson Andrew Pozo Liberati</au><au>Marques, Marília Gonçalves</au><au>Luiz Carlos De Almeida</au><au>Trautwein, Leandro Mouta</au><format>book</format><genre>unknown</genre><ristype>DATA</ristype><title>Reinforced concrete flat slabs with openings at different distances from the column</title><date>2021-03-25</date><risdate>2021</risdate><abstract>The increase in the use of flat slabs and the need of the openings for the passage of installations, such as hydraulic and electrical, which significantly reduces the punching shear resistance capacity of the slab, makes the understanding of the influence of openings in this type of structure extremely necessary. The influence in the structural behaviour of flat slabs with openings at different distances from the column was investigated through five square slabs (1,800 mm x 1,800 mm x 130 mm) supported on square columns (150 mm x 150 mm) tested until failure. The results obtained experimentally were compared with results available in the literature, as well as with responses predicted from the normative instructions. The results confirm high stresses concentration in the region between the column and the opening and that opening situated at 3d from the column have no influence on the failure load for the tested slabs.</abstract><pub>SciELO journals</pub><doi>10.6084/m9.figshare.14307324</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.6084/m9.figshare.14307324
ispartof
issn
language eng
recordid cdi_datacite_primary_10_6084_m9_figshare_14307324
source DataCite
subjects Civil Geotechnical Engineering
FOS: Civil engineering
title Reinforced concrete flat slabs with openings at different distances from the column
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T11%3A23%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.au=Louren%C3%A7o,%20Diego%20Da%20Silva&rft.date=2021-03-25&rft_id=info:doi/10.6084/m9.figshare.14307324&rft_dat=%3Cdatacite_PQ8%3E10_6084_m9_figshare_14307324%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true