Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis

This is the metadata for the research paper "Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis". In this study we elucidate the possible reasons for the increased ohmic resistances in zero-gap alkaline water electrolysis. We critically assess the methodolo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lira Garcia Barros, Rodrigo, Kelleners, Mathy H. G., van Bemmel, Lucas, van der Leegte, Thijmen V. N., van der Schaaf, John, de Groot, Matheus
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Lira Garcia Barros, Rodrigo
Kelleners, Mathy H. G.
van Bemmel, Lucas
van der Leegte, Thijmen V. N.
van der Schaaf, John
de Groot, Matheus
description This is the metadata for the research paper "Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis". In this study we elucidate the possible reasons for the increased ohmic resistances in zero-gap alkaline water electrolysis. We critically assess the methodology for estimating the ohmic resistance of zero-gap electrolyzers as reported in literature. In order to monitor variations in ohmic resistance during zero-gap alkaline electrolysis, we employ electrochemical impedance spectroscopy (EIS) at both low and high current densities. Both 2- and 4-terminal configurations are used to address additional contact or cable resistance. Furthermore, we evaluate the diaphragm wettability and the bubble behavior both outside and inside the diaphragm using a photographic method to better understand the possible role of bubbles. Our intention is that these findings will help to open the way for electrolyzers with reduced ohmic resistance, enabling efficient operation at higher current densities. ABSTRACT This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.
doi_str_mv 10.17632/xfm53n2sjm.1
format Dataset
fullrecord <record><control><sourceid>datacite_PQ8</sourceid><recordid>TN_cdi_datacite_primary_10_17632_xfm53n2sjm_1</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_17632_xfm53n2sjm_1</sourcerecordid><originalsourceid>FETCH-datacite_primary_10_17632_xfm53n2sjm_13</originalsourceid><addsrcrecordid>eNqVjrEKwjAURbM4iDq6vx9IbVrUD5CKu-7hkb62T5O0JBGtX28RwdnpDvfAOUKsVZ6p_a4sNs_GbUtfxKvL1FycK3s3XGNi30LqCNibQBiphr5zbCBQ5JjQG4rTBy8KvWxxALQ3tOwJHpgoAFkyKfR2nOilmDVoI62-uxDyWF0OJzlp0HAiPQR2GEatcv2J0r8orcp_-TdyS0i6</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>dataset</recordtype></control><display><type>dataset</type><title>Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis</title><source>DataCite</source><creator>Lira Garcia Barros, Rodrigo ; Kelleners, Mathy H. G. ; van Bemmel, Lucas ; van der Leegte, Thijmen V. N. ; van der Schaaf, John ; de Groot, Matheus</creator><creatorcontrib>Lira Garcia Barros, Rodrigo ; Kelleners, Mathy H. G. ; van Bemmel, Lucas ; van der Leegte, Thijmen V. N. ; van der Schaaf, John ; de Groot, Matheus</creatorcontrib><description>This is the metadata for the research paper "Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis". In this study we elucidate the possible reasons for the increased ohmic resistances in zero-gap alkaline water electrolysis. We critically assess the methodology for estimating the ohmic resistance of zero-gap electrolyzers as reported in literature. In order to monitor variations in ohmic resistance during zero-gap alkaline electrolysis, we employ electrochemical impedance spectroscopy (EIS) at both low and high current densities. Both 2- and 4-terminal configurations are used to address additional contact or cable resistance. Furthermore, we evaluate the diaphragm wettability and the bubble behavior both outside and inside the diaphragm using a photographic method to better understand the possible role of bubbles. Our intention is that these findings will help to open the way for electrolyzers with reduced ohmic resistance, enabling efficient operation at higher current densities. ABSTRACT This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.</description><identifier>DOI: 10.17632/xfm53n2sjm.1</identifier><language>eng</language><publisher>Mendeley Data</publisher><subject>Electrochemical Cell ; Impedance ; Potentiometry</subject><creationdate>2024</creationdate><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0001-8654-8664 ; 0000-0002-2856-8592 ; 0000-0002-9227-7642</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>780,1894</link.rule.ids><linktorsrc>$$Uhttps://commons.datacite.org/doi.org/10.17632/xfm53n2sjm.1$$EView_record_in_DataCite.org$$FView_record_in_$$GDataCite.org$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Lira Garcia Barros, Rodrigo</creatorcontrib><creatorcontrib>Kelleners, Mathy H. G.</creatorcontrib><creatorcontrib>van Bemmel, Lucas</creatorcontrib><creatorcontrib>van der Leegte, Thijmen V. N.</creatorcontrib><creatorcontrib>van der Schaaf, John</creatorcontrib><creatorcontrib>de Groot, Matheus</creatorcontrib><title>Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis</title><description>This is the metadata for the research paper "Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis". In this study we elucidate the possible reasons for the increased ohmic resistances in zero-gap alkaline water electrolysis. We critically assess the methodology for estimating the ohmic resistance of zero-gap electrolyzers as reported in literature. In order to monitor variations in ohmic resistance during zero-gap alkaline electrolysis, we employ electrochemical impedance spectroscopy (EIS) at both low and high current densities. Both 2- and 4-terminal configurations are used to address additional contact or cable resistance. Furthermore, we evaluate the diaphragm wettability and the bubble behavior both outside and inside the diaphragm using a photographic method to better understand the possible role of bubbles. Our intention is that these findings will help to open the way for electrolyzers with reduced ohmic resistance, enabling efficient operation at higher current densities. ABSTRACT This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.</description><subject>Electrochemical Cell</subject><subject>Impedance</subject><subject>Potentiometry</subject><fulltext>true</fulltext><rsrctype>dataset</rsrctype><creationdate>2024</creationdate><recordtype>dataset</recordtype><sourceid>PQ8</sourceid><recordid>eNqVjrEKwjAURbM4iDq6vx9IbVrUD5CKu-7hkb62T5O0JBGtX28RwdnpDvfAOUKsVZ6p_a4sNs_GbUtfxKvL1FycK3s3XGNi30LqCNibQBiphr5zbCBQ5JjQG4rTBy8KvWxxALQ3tOwJHpgoAFkyKfR2nOilmDVoI62-uxDyWF0OJzlp0HAiPQR2GEatcv2J0r8orcp_-TdyS0i6</recordid><startdate>20241001</startdate><enddate>20241001</enddate><creator>Lira Garcia Barros, Rodrigo</creator><creator>Kelleners, Mathy H. G.</creator><creator>van Bemmel, Lucas</creator><creator>van der Leegte, Thijmen V. N.</creator><creator>van der Schaaf, John</creator><creator>de Groot, Matheus</creator><general>Mendeley Data</general><scope>DYCCY</scope><scope>PQ8</scope><orcidid>https://orcid.org/0000-0001-8654-8664</orcidid><orcidid>https://orcid.org/0000-0002-2856-8592</orcidid><orcidid>https://orcid.org/0000-0002-9227-7642</orcidid></search><sort><creationdate>20241001</creationdate><title>Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis</title><author>Lira Garcia Barros, Rodrigo ; Kelleners, Mathy H. G. ; van Bemmel, Lucas ; van der Leegte, Thijmen V. N. ; van der Schaaf, John ; de Groot, Matheus</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-datacite_primary_10_17632_xfm53n2sjm_13</frbrgroupid><rsrctype>datasets</rsrctype><prefilter>datasets</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Electrochemical Cell</topic><topic>Impedance</topic><topic>Potentiometry</topic><toplevel>online_resources</toplevel><creatorcontrib>Lira Garcia Barros, Rodrigo</creatorcontrib><creatorcontrib>Kelleners, Mathy H. G.</creatorcontrib><creatorcontrib>van Bemmel, Lucas</creatorcontrib><creatorcontrib>van der Leegte, Thijmen V. N.</creatorcontrib><creatorcontrib>van der Schaaf, John</creatorcontrib><creatorcontrib>de Groot, Matheus</creatorcontrib><collection>DataCite (Open Access)</collection><collection>DataCite</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Lira Garcia Barros, Rodrigo</au><au>Kelleners, Mathy H. G.</au><au>van Bemmel, Lucas</au><au>van der Leegte, Thijmen V. N.</au><au>van der Schaaf, John</au><au>de Groot, Matheus</au><format>book</format><genre>unknown</genre><ristype>DATA</ristype><title>Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis</title><date>2024-10-01</date><risdate>2024</risdate><abstract>This is the metadata for the research paper "Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis". In this study we elucidate the possible reasons for the increased ohmic resistances in zero-gap alkaline water electrolysis. We critically assess the methodology for estimating the ohmic resistance of zero-gap electrolyzers as reported in literature. In order to monitor variations in ohmic resistance during zero-gap alkaline electrolysis, we employ electrochemical impedance spectroscopy (EIS) at both low and high current densities. Both 2- and 4-terminal configurations are used to address additional contact or cable resistance. Furthermore, we evaluate the diaphragm wettability and the bubble behavior both outside and inside the diaphragm using a photographic method to better understand the possible role of bubbles. Our intention is that these findings will help to open the way for electrolyzers with reduced ohmic resistance, enabling efficient operation at higher current densities. ABSTRACT This study investigates the increased ohmic resistances observed in zero-gap alkaline water electrolyzers, aiming to provide insights that can help enhance electrolyzer efficiency and enable operation at higher current densities. Electrochemical impedance spectroscopy (EIS) has been employed in combination with chronopotentiometry, utilizing a custom-designed flow cell with nickel perforated electrodes and a Zirfon UTP 500 diaphragm. Observed differences in area-ohmic resistance values obtained through I-V fitting and EIS, are ascribed to a non-linear Tafel slope at higher current densities. Ohmic resistance values measured with EIS are up to 27% higher than the ex-situ determined value, a significantly smaller percentage than expected based on previous studies. The presence of bubbles outside and inside the diaphragm is identified as the key factor contributing to this increased resistance. We recommend the use of an improved fitting approach, accounting for non-linear Tafel behavior, and the use of a 4-terminal configuration when performing EIS measurements to minimize cable and contact resistance.</abstract><pub>Mendeley Data</pub><doi>10.17632/xfm53n2sjm.1</doi><orcidid>https://orcid.org/0000-0001-8654-8664</orcidid><orcidid>https://orcid.org/0000-0002-2856-8592</orcidid><orcidid>https://orcid.org/0000-0002-9227-7642</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier DOI: 10.17632/xfm53n2sjm.1
ispartof
issn
language eng
recordid cdi_datacite_primary_10_17632_xfm53n2sjm_1
source DataCite
subjects Electrochemical Cell
Impedance
Potentiometry
title Elucidating the increased ohmic resistances in zero-gap alkaline water electrolysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T23%3A04%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-datacite_PQ8&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.au=Lira%20Garcia%20Barros,%20Rodrigo&rft.date=2024-10-01&rft_id=info:doi/10.17632/xfm53n2sjm.1&rft_dat=%3Cdatacite_PQ8%3E10_17632_xfm53n2sjm_1%3C/datacite_PQ8%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true