Injector diameter influence in the generation of minibubbles for space applications

To finish my second academic year I have to make a training course, I choose it in the Microgravity Laboratory at the Castelldefels School of Technology (EPSC) of the Technical University of Catalonia (UPC). My report consists in study and compares the results obtained from different experiment with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Sann, Evie
Format: Dissertation
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Sann, Evie
description To finish my second academic year I have to make a training course, I choose it in the Microgravity Laboratory at the Castelldefels School of Technology (EPSC) of the Technical University of Catalonia (UPC). My report consists in study and compares the results obtained from different experiment with diameter of T-junction of 1 mm and 2.5 mm. And so see the influence injection diameter on the generation of minibubbles. In fact I have to make a biphasic flow rate between 2 fluids, air and liquid in microgravity conditions, and observe the minibubbles created thanks to this mixture in a T-junction which has 2.5 mm for the diameter. I have to analyze different velocities such as the velocities of bubble, unit cell, slug of liquid, gas and liquid. And from this data I make a data sheet thanks to Excel and graphs. Then I compared my results with results which had already done by PhD. Arias which had made his thesis on two-phase flows in microgravity conditions with a diameter of T-junction of 1 mm.
format Dissertation
fullrecord <record><control><sourceid>csuc_XX2</sourceid><recordid>TN_cdi_csuc_recercat_oai_recercat_cat_2072_200987</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>oai_recercat_cat_2072_200987</sourcerecordid><originalsourceid>FETCH-csuc_recercat_oai_recercat_cat_2072_2009873</originalsourceid><addsrcrecordid>eNqdi7sOwjAMRbswIOAf_ANIpQyFGYFghr1yjAOuUifK4_8JCImd4b6kc-fN9aIjU_YR7oITZ44gal1hJa4N8pPhwcoRs3gFb2ESFVOMcZzA1l8KWFEMwQl9oLRsZhZd4tU3F83mdLwdzmtKhYbIxLGSg0f5jbe6tu-qtftdv_3n8wIJKkYD</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>dissertation</recordtype></control><display><type>dissertation</type><title>Injector diameter influence in the generation of minibubbles for space applications</title><source>Recercat</source><creator>Sann, Evie</creator><creatorcontrib>Sann, Evie</creatorcontrib><description>To finish my second academic year I have to make a training course, I choose it in the Microgravity Laboratory at the Castelldefels School of Technology (EPSC) of the Technical University of Catalonia (UPC). My report consists in study and compares the results obtained from different experiment with diameter of T-junction of 1 mm and 2.5 mm. And so see the influence injection diameter on the generation of minibubbles. In fact I have to make a biphasic flow rate between 2 fluids, air and liquid in microgravity conditions, and observe the minibubbles created thanks to this mixture in a T-junction which has 2.5 mm for the diameter. I have to analyze different velocities such as the velocities of bubble, unit cell, slug of liquid, gas and liquid. And from this data I make a data sheet thanks to Excel and graphs. Then I compared my results with results which had already done by PhD. Arias which had made his thesis on two-phase flows in microgravity conditions with a diameter of T-junction of 1 mm.</description><language>eng</language><publisher>Universitat Politècnica de Catalunya</publisher><subject>Aeronàutica i espai ; Bombolles ; Bubbles ; Dinàmica ; Effect of reduced gravity on ; Gravetat ; Injection ; Liquids ; Microbubbles ; Reduced gravity environments ; Àrees temàtiques de la UPC</subject><creationdate>2012</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,311,776,881,26951</link.rule.ids><linktorsrc>$$Uhttps://recercat.cat/handle/2072/200987$$EView_record_in_Consorci_de_Serveis_Universitaris_de_Catalunya_(CSUC)$$FView_record_in_$$GConsorci_de_Serveis_Universitaris_de_Catalunya_(CSUC)$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Sann, Evie</creatorcontrib><title>Injector diameter influence in the generation of minibubbles for space applications</title><description>To finish my second academic year I have to make a training course, I choose it in the Microgravity Laboratory at the Castelldefels School of Technology (EPSC) of the Technical University of Catalonia (UPC). My report consists in study and compares the results obtained from different experiment with diameter of T-junction of 1 mm and 2.5 mm. And so see the influence injection diameter on the generation of minibubbles. In fact I have to make a biphasic flow rate between 2 fluids, air and liquid in microgravity conditions, and observe the minibubbles created thanks to this mixture in a T-junction which has 2.5 mm for the diameter. I have to analyze different velocities such as the velocities of bubble, unit cell, slug of liquid, gas and liquid. And from this data I make a data sheet thanks to Excel and graphs. Then I compared my results with results which had already done by PhD. Arias which had made his thesis on two-phase flows in microgravity conditions with a diameter of T-junction of 1 mm.</description><subject>Aeronàutica i espai</subject><subject>Bombolles</subject><subject>Bubbles</subject><subject>Dinàmica</subject><subject>Effect of reduced gravity on</subject><subject>Gravetat</subject><subject>Injection</subject><subject>Liquids</subject><subject>Microbubbles</subject><subject>Reduced gravity environments</subject><subject>Àrees temàtiques de la UPC</subject><fulltext>true</fulltext><rsrctype>dissertation</rsrctype><creationdate>2012</creationdate><recordtype>dissertation</recordtype><sourceid>XX2</sourceid><recordid>eNqdi7sOwjAMRbswIOAf_ANIpQyFGYFghr1yjAOuUifK4_8JCImd4b6kc-fN9aIjU_YR7oITZ44gal1hJa4N8pPhwcoRs3gFb2ESFVOMcZzA1l8KWFEMwQl9oLRsZhZd4tU3F83mdLwdzmtKhYbIxLGSg0f5jbe6tu-qtftdv_3n8wIJKkYD</recordid><startdate>20120727</startdate><enddate>20120727</enddate><creator>Sann, Evie</creator><general>Universitat Politècnica de Catalunya</general><scope>XX2</scope></search><sort><creationdate>20120727</creationdate><title>Injector diameter influence in the generation of minibubbles for space applications</title><author>Sann, Evie</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-csuc_recercat_oai_recercat_cat_2072_2009873</frbrgroupid><rsrctype>dissertations</rsrctype><prefilter>dissertations</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Aeronàutica i espai</topic><topic>Bombolles</topic><topic>Bubbles</topic><topic>Dinàmica</topic><topic>Effect of reduced gravity on</topic><topic>Gravetat</topic><topic>Injection</topic><topic>Liquids</topic><topic>Microbubbles</topic><topic>Reduced gravity environments</topic><topic>Àrees temàtiques de la UPC</topic><toplevel>online_resources</toplevel><creatorcontrib>Sann, Evie</creatorcontrib><collection>Recercat</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sann, Evie</au><format>dissertation</format><genre>dissertation</genre><ristype>THES</ristype><btitle>Injector diameter influence in the generation of minibubbles for space applications</btitle><date>2012-07-27</date><risdate>2012</risdate><abstract>To finish my second academic year I have to make a training course, I choose it in the Microgravity Laboratory at the Castelldefels School of Technology (EPSC) of the Technical University of Catalonia (UPC). My report consists in study and compares the results obtained from different experiment with diameter of T-junction of 1 mm and 2.5 mm. And so see the influence injection diameter on the generation of minibubbles. In fact I have to make a biphasic flow rate between 2 fluids, air and liquid in microgravity conditions, and observe the minibubbles created thanks to this mixture in a T-junction which has 2.5 mm for the diameter. I have to analyze different velocities such as the velocities of bubble, unit cell, slug of liquid, gas and liquid. And from this data I make a data sheet thanks to Excel and graphs. Then I compared my results with results which had already done by PhD. Arias which had made his thesis on two-phase flows in microgravity conditions with a diameter of T-junction of 1 mm.</abstract><pub>Universitat Politècnica de Catalunya</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_csuc_recercat_oai_recercat_cat_2072_200987
source Recercat
subjects Aeronàutica i espai
Bombolles
Bubbles
Dinàmica
Effect of reduced gravity on
Gravetat
Injection
Liquids
Microbubbles
Reduced gravity environments
Àrees temàtiques de la UPC
title Injector diameter influence in the generation of minibubbles for space applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T16%3A24%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-csuc_XX2&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&rft.genre=dissertation&rft.btitle=Injector%20diameter%20influence%20in%20the%20generation%20of%20minibubbles%20for%20space%20applications&rft.au=Sann,%20Evie&rft.date=2012-07-27&rft_id=info:doi/&rft_dat=%3Ccsuc_XX2%3Eoai_recercat_cat_2072_200987%3C/csuc_XX2%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true